T: 01246 455565. F: 01246 455244. W: E: Recommended Lux Levels The following guidance tables provide Recommended lux Levels for specific working areas within commercial, industrial and public sector buildings. These figures are based on the Recommended lux Levels by CIBSE (Chartered Institute of Building Services Engineers). and the code for interior lighting. Tables are for guidance only. Suggested Suggested Domestic Lux Level Retail Lux Level General lighting 120 Sales area 300. Kitchen 250 Till area 500. Bedrooms 120 Wrapper table 500. Sewing room 500 Dressing rooms 300. Bathroom 250 Shop window (crowded street) 1600. Dining room 500 Shop window (commercial) 3000. Suggested Suggested Education Lux Level Car Parks Lux Level Classroom, tutorial rooms 300 Parking bays (multi storey / underground) 75. Lecture hall 500 Access lanes (M-S/UG) 75. Technical drawing rooms 750 Ramps (M-S/UG) 150.
T: 01246 455565 F: 01246 455244 W: www.reconelectrical.co.uk E: sales@reconelectrical.co.uk Units 1-6 Ambrose Buildings, Broombank Road, Chesterfield, Derbyshire, S41 9QJ