PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: barber

Rerate Specification Date - EagleiTechnologies.com

Rerate Specification Date 5/09/2012. Client: ACME Chemical Report No.: Vessel: ACAX 80005. Contact: John Smith Phone No.: 555-836-2223 Year Built: 1970. EXECUTIVE SUMMARY. The Delaware Plant Reliability Engineer at ACME Chemicals in Claymont, DE requested Eagle Inspection Technologies to include Rerate calculations with the inspection report to support the proposed Rerate for the DOT Railcar ACAX 80005 to be set on stationary supports and continue in service as a stationary pressure vessel in Fluosulfonic Acid service. This request was due to the requirements of the PA Dept. of Labor and Industry for pressure vessels operating within their jurisdiction. The calculations contained herein were based on the client request to Rerate the vessel to 25psig at 200 F.

ClienW ACME Chemical PRESSURE VESSEL NOZZLE CALCULATIONS Date 5/9/2012 Project No.:20090.039 VesselACAX 80005 Year Built 1970 ASME S8 D1, UG-27_45 9.875 Inside Radius, in. 25.0 Design Pressure, psi 1.00 Joint Efficeincy

Loading..

Tags:

  Specification, Arrete, Rerate specification

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of Rerate Specification Date - EagleiTechnologies.com

Related search queries