Transcription of RF Connector guide
{{id}} {{{paragraph}}}
RF Connector guide RF Connector guide HUBER+SUHNER is certified according to ISO 9001, ISO 14001, ISO/TS 16949 and IRIS. WAIVER HUBER+SUHNER AG. 648116 It is exclusively in written agreements that we provide our custom- Radio Frequency Division ers with warrants and representations as to the technical specifica- tions and/or the fitness for any particular purpose. The facts and 9100 Herisau/Switzerland figures contained herein are carefully compiled to the best of Tel. +41 (71) 353 41 11. our knowledge, but they are intended for general informational Fax +41 (71) 353 44 44. purposes only. HUBER+SUHNER . RF Connector guide . Understanding Connector technology Published by HUBER+SUHNER.
The impedance of a coaxial line can also bedeterminedbythe ratioof diameters (refer toFigure 13) and the dielectric constant εr. Z =377Ω 2πε r ×ln D d =60Ω εr ×ln D d =138Ω εr ×log D d (6) 1.2.5.1 Characteristic Impedance of a low-loss Line at High Frequencies =