Rytons Roof Ventilators

1CI/SfB reference by RIBA SfB Agency(47)Xn6 RoofNovember 2018 Rytons roof VentilatorsNew interactive guide with links to technical information23 Pitched roof Dormer (E)10mm or 25mm to suit pitch10mm or 25mm to suit pitchCold Deck Flat roof (F)25mm25mmPitched roof Below 15 (C)25mm25mmMono-Pitched roof (D)5mm10mm or 25mm to suit pitchFlat roof Abutment (G)25mm25mmPitched roof Over 15 (A)10mm10mmNOTE: 5mm required at ridge where pitch exceeds 35 or span exceeds (B)25mm25mm5mmNOTE: where the ceiling is partially or completely sloping and the ventilation path is blocked by a roof light, the roof void should have additional ventilation openings immediately below and above the block (5mm below the block and 10mm above on a partially sloping ceiling and 5mm below and 25mm above on a completely sloping ceiling).

8 Product Guides & Services Boiler, Stove & Fire Ventilators (including Acoustic) Background Room Ventilators (including Acoustic) Louvre and Hit & Miss Ventilators

Loading..

Tags:

  Background, Roof, Room, Ventilator, Tryon, Background room ventilators, Rytons roof ventilators