555032 04/2016 2016 Schluter Systems Schluter -DITRA-HEAT Installation GuideEsta gu a est disponible en espa ol. Para obtener una copia, llame por tel fono a nuestro servicio al cliente o desc rguela desde nuestro sitio Internet : 3 Details8 Movement Joints9 Wood UnderlaymentInstallation10 Membrane11 Heating Cables16 Thin-set Facts16 Testing & Certifications18 208 V Applications19 Heating Cable Tests Log20 WarrantySchluter -Systems written Installation instructions shall have precedence over referenced industry standard guidelines and Installation procedures insofar as referenced information may contain overlapping or conflicting requirements. Type, thickness , and format of the ceramic or stone tile surface covering must be suitable for the intended cables must be installed by a qualified person in accordance with this handbook and with the National Electric Code (USA) or Canadian Electric Code Part I (CAN) as applicable.
layer OSB or plywood floor interior dry or wet areas Limitations minimum 2" x 2" (50 mm x 50 mm) tile Requirements maximum spacing of joists, I-joists, or floor trusses is 24" (610 mm) o.c. double layer wood floor consisting of: • minimum subfloor thickness – 23/32", 3/4" nom. (19 mm) tongue-and-groove • minimum underlayment thickness –