Self-Contained Breathing Apparatus (SCBA). Cylinder Life-Extension Study FINAL REPORT. Prepared by: CACI: David Flage David Hunter Steve Robinson Blackstone Group, LLC: Robert Ceres Digital Wave Corporation: Michael Gorman Steven Ziola Under Contract: N00024-11-C-4314. August 2012. Self-Contained Breathing Apparatus (SCBA). Cylinder Life-Extension Study Table of Contents 1 Executive Summary .. 1-1. 2 SCBA Background .. 2-1. 3 Study 3-1. Overall Approach and Study Design .. 3-1. ISO 11119-2 Tests Not Accomplished and 3-2. ISO 11119-2 Tests Accomplished with Noted 3-3. Additional Testing Conducted, Not Required by ISO 3-5. Study Execution and Results .. 3-5. 4 Findings and 4-1. 4-1. 4-2. 5 5-1. 6 References .. 6-1. Appendices Appendix A SCBA Hydrostatic Test Data Analysis.
fiberglass) or carbon fiber-reinforced polymer (CFRP). The older cylinders are GFRP-wrapped, and tensile stress is shared by the GFRP and the aluminum alloy. The newer cylinders are wrapped with a considerably stronger CFRP. On CFRP cylinders, the aluminum alloy serves as an impermeable gas barrier, not a strength member.