AMERICA FRABA Inc. 1800 East State Street, Suite 148 Hamilton, NJ 08609-2020, USA T +1-609-750-8705, F +1-609-750-8703 , EUROPE POSITAL GmbH Carlswerkstrasse 13c D-51063 K ln, Germany T +49 221 96213-0, F +49 221 96213-20 , ASIA FRABA Pte. Kallang Avenue #01-00 Pico Creative Centre Singapore 339411, Singapore T +65 65148880, F +65 62711792 , IMPLEME NT AT ION OF SSI MAST ER I NT ERFA CE APPLICAT ION NO T E Application Note 12 August 2013 IMPLEME NT AT ION OF SSI MAST ER I NT ERFA CE APPLICAT ION NO T E 2013-11-08 2/26 10021488 For additional information about our products click on the links below: IXARC Rotary Encoders TILTIX Inclinometers LINARIX Linear Sensors Table of Contents IMPLEME NT AT ION OF SSI MAST ER I NT ERFA CE APPLICAT ION NO T E 2013-11-08 3/26 10021488 Table of Figures.

IMPLEMENTATION OF SSI MASTER INTERFACE APPLICATION NOTE 2013-11-08 6/26 Art.No. 10021488 1. SSI Theory Synchronous Serial Interface (SSI) is a widely used serial interface standard for industrial applications especially, rotary encoders. It is a point-to-point connection from a master (e.g. PLC, microcontroller or