Standard Operating Procedure for - Fisher Sci

Standard Operating Procedure for: Total Suspended Solids ID: TSSolids Revision: 2 May 2007 Page 2 of 11 Table of Contents 1 Identification of the test method .. 3 2 Applicable matrix or matrices: .. 3 3 Detection Limit .. 3 4 Scope of the test method .. 3 5 Summary of test 3 6 Definitions .. 3 7 Interferences .. 3 8 Health and safety .. 4 9 Personnel qualifications .. 4 10 Equipment and supplies .. 4 11 Reagents and standards .. 4 12 Sample collection, preservation, shipment and storage .. 4 13 Quality control .. 5 14 Calibration and standardization .. 6 15 Procedure .. 6 16 Data acquisition, calculations, and reporting .. 8 17 Computer hardware and software .. 8 18 Method performance .. 8 19 Pollution prevention.

4. If experience has shown that samples from a site normally have very high levels of suspended solids and/or frequently cause clogging, the analyst may reduce the sample volume, as long as the mass of solid collected falls in the range of 2 to 200 mg. c. For highly turbid samples or samples with expected high amounts of TSS: 1.