PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: biology

Standard Practice for Liquid Penetrant Examination

Designation: E 1417 99An American National StandardStandard Practice forLiquid Penetrant Examination1 This Standard is issued under the fixed designation E 1417; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or This Practice establishes the minimum requirements forconducting Liquid Penetrant Examination of nonporous metal,and nonmetal The Penetrant Examination processes described in thispractice are applicable to in-process, final, and maintenance(in-service) inspections. These processes are applicable for thedetection of discontinuities, such as lack of fusion, corrosion,cracks, laps, cold shuts, and porosity, that are open or con-nected to the surface of the component under Caution must be exercised in the usage of elevatedtemperature with components manufactured from thermoplas-tic materials.

conducting liquid penetrant examination of nonporous metal, and nonmetal components. 1.2 The penetrant examination processes described in this practice are applicable to in-process, final, and maintenance (in-service) inspections. These processes are applicable for the detection of discontinuities, such as lack of fusion, corrosion,

Loading..

Tags:

  Practices, Standards, Liquid, Examination, Penetrant, Standard practice for liquid penetrant examination, Liquid penetrant examination, Penetrant examination

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of Standard Practice for Liquid Penetrant Examination

Related search queries