Standard Practice for Liquid Penetrant Testing1

Designation: E1417/E1417M 16 Standard Practice forLiquid Penetrant Testing1 This Standard is issued under the fixed designation E1417/E1417M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last superscript epsilon ( ) indicates an editorial change since the last revision or Standard has been approved for use by agencies of the Department of Scope* This Practice establishes the minimum requirements forconducting Liquid Penetrant examination of nonporous metal,and nonmetal This Practice replaces The Penetrant examination processes described in thispractice are applicable to in-process, final, and maintenance(in-service) examinations.

5.1.3.5 Sensitivity Level 4—Ultrahigh. 5.2 Developers shall be of the following forms: 5.2.1 Form a—Dry powder. 5.2.2 Form b—Water-soluble. 5.2.3 Form c—Water-suspendable. 5.2.4 Form d—Nonaqueous for Type I fluorescent pen-etrant. 5.2.5 Form e—Nonaqueous for Type II visible dye. 5.2.6 Form f—Specific application.