STRAIN GAUGE INSTALLATION - OMEGA

E-12 ESTRAIN GAGESSTRAIN GAUGE INSTALLATIONHOW TO POSITION STRAIN GAUGES TO MONITORBENDING, AXIAL, SHEAR, AND TORSIONAL LOADS STRAIN is defined as the ratio of thechange in length to the initialunstressed reference length. A straingauge is the element that senses thischange and converts it into anelectrical signal. This can beaccomplished because a straingauge changes resistance as it isstretched, or compressed, similar towire. For example, when wire isstretched, its cross-sectional areadecreases; therefore, its important factors that must beconsidered before selecting a straingauge are the direction, type, andresolution of the STRAIN you wish measure minute strains, the usermust be able to measure minuteresistance changes.

C through F. For example, if a positive (tensile) strain is applied to gauges 1 and 3, and a negative (compressive) strain to gauges 2 and 4, the total strain would be 4 times the strain on one gauge. See Figure C. If total strain is four times the strain on one gauge, this means that the output will be four times larger. Therefore, greater ...