Technical Bulletin TB001680. Profile: General Data creation: March 2017. Wrote by: In some cases DEA 701 programming fails Approved by: & Revision: 01. Products involved: Platform: DW WIND. All DW platform WIND with mainboard DEA 701. S/N: All production What the technician observes: It is not possible to program DEA701 because of Communication Error appear. Root cause: To increase the security of the DEA 701, some modifications were done on the plastic box containing it. Because of these modifications, the pins of the hardware key COULD NOT CORRECTLY TOUCH the pads ON. THE BOARD used to download the setting files. The pads on the mainboard are centered inside the window (see Picture 1) and, instead, it is necessary that they are NOT CENTERED (see Picture 2) or Technician is not using the right version of MemWriter.

2 Intervention to do: CASE 1: IF TECHNICIAN IS PROGRAMMING THE MAINBOARD ON THE APPLIANCE: If the technician during the mainboard programming or re-programming is facing an error with the Memwriter