TI081D/06/ InformationProline Promag 10 DElectromagnetic flow measuring systemFlow measurement of liquids in water or wastewater applicationsApplicationElectromagnetic flowmeter for bidirectional measurement of liquids with: A minimum conductivity of 50 S/cm Drinking water Wastewater Flow measurement up to 4700 dm /min (1250 gal/min) Fluid temperature up to +60 C (140 F) Process pressures up to 16 bar (232 psi) Polyamide lining material Drinking water approvals: KTW/W270 WRAS BS 6920 ACS NSF 61 Your benefitsThe measuring devices offer you cost-effective flow measurement with a high degree of accuracy for a wide range of process uniform Proline transmitter concept comprises: High degree of reliability and measuring stability Uniform operating conceptThe tried-and-tested Promag sensors offer: No pressure loss Not sensitive to vibrations Simple installatio
TI081D/06/en/11.09 71105327 Technical Information Proline Promag 10D Electromagnetic flow measuring system Flow measurement of liquids in water or wastewater applications