TI093D/24/ InformationProline Promag 10 WElectromagnetic Flow Measuring SystemFlow measurement of liquids in water or wastewater applicationsApplicationElectromagnetic flowmeter for bidirectional measurement of liquids with a minimum conductivity of 50 S/cm: Drinking water Wastewater Sewage sludge Flow measurement up to 700 Mgal/day (110,000 m /h) Fluid temperature up to +175 F (80 C) Process pressures up to 580 psi (40 bar) Lengths in accordance with DVGW/ISOA pplication-specific lining materials: Polyurethane and hard rubberLined measuring pipes with materials approved for drinking water: KTW, WRAS, NSF, ACS, benefitsPromag measuring devices offer you cost-effective flow measurement with a high degree of accuracy for a wide range of process uniform Proline transmitter concept comprises: High degree of reliability and measuring stability Uniform operating conceptThe tried-and-tested Promag sensors offer: No pressure loss Not sensitive to vibrations Simple installation and commissioningProline Promag 10 W2 Endress + HauserTable of contentsFunction and system design.
Proline Promag 10 W Endress + Hauser 3 Function and system design Measuring principle Following Faraday's law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field. In the electromagnetic measuring principle, th e flowing medium is the moving conductor.
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
Prowirl 72, Vortex Measuring System, Operating instructions PROline, Operating instructions, PROline Prowirl 73, Operating instructions PROline Prowirl 73, Electromagnetic Flow Measuring System, Proline, Instructions, Operating, Promag 55 PROFIBUS PA, Proline Promag 55 PROFIBUS PA, Technical Information, Proline Prosonic Flow, Technical Information Proline Promag 55S, CenterLine Filter Wheel, HYDROSTATIC PRESSURE TESTING