Transcription of Technical Information Proline Promag 50W, 53W
{{id}} {{{paragraph}}}
TI046D/24/ InformationProline Promag 50W, 53 WElectromagnetic Flow Measuring SystemFlow measurement of liquids in water or wastewater applicationsApplicationElectromagnetic flowmeter for bidirectional measurement of liquids with a minimum conductivity of 5 S/cm: Drinking water Wastewater Sewage sludge Flow measurement up to 110 000 m /h (484 315 gal/min) Fluid temperature up to +80 C (+176 F) Process pressures up to 40 bar (580 psi) Lengths in accordance with DVGW/ISOA pplication-specific lining of the measuring pipe from polyurethane or hard rubber with the following drinking water permissions: KTW WRAS NSF ACSA pprovals for hazardous area: ATEX IECEx FM CSA NEPSIC onnection to process control system: HART PROFIBUS DP/PA FOUNDATION Fieldbus MODBUS RS485 Your benefitsPromag measuring devices offer you cost-effective flow measurement with a high degree of accuracy for a wide range of process uniform Proline transmitter concept comprises: Modular device and operating concept resulting in a higher degree of efficiency Software options for batching, electrode cleaning and for measuring pulsating flow High degree of reliability and measuring stability Uniform operating conceptThe tried-and-tested Promag sensors offer: No pressure loss Not sensitive to vibrations Simple installati
Proline Promag 50W, 53W Endress+Hauser 3 Function and system design Measuring principle Following Faraday's law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field. In the electromagnetic measuring principle, the flowing medium is the moving conductor.
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}