TI071D/06/ InformationProline Promag 55 SElectromagnetic Flow Measuring SystemFlow rate measurement of liquids with solids content orinhomogeneous liquidsApplicationElectromagnetic flowmeter for bidirectional meas-urement of liquids with a minimum conductivityof 5 S/cm in particular fluids with solids, and fluids which are abrasive, inhomogeneous or tend to build-up, for example: Chemical/mechanical pulps, paper pulp or wood pulp with solids contents up to 15 Fruit mashes, fruit concentrates and final products (salad dressings, soups with vegetable pieces) Slurries containing high amounts of sand or stone with an abrasive effect, ore slurry or mortar Chemically inhomogeneous fluids ( additives) Thick wastewater sludges Flow measurement up to 9600 m3/h Can be used up to +180 C and max.
Proline Promag 55S 8 Endress+Hauser Electrical connections 20 to 260 V AC, 45 to 65 Hz 20 to 64 V DC Cable entries Power-supply and signal cables (inputs/outputs): • Cable gland M20 x 1.5 (8 to 12 mm)