Technical Note Using GWR for Level in high pressure steam applications 00840-0100-4530, Rev DB October 2016. Using Guided Wave Radar for Level in high pressure steam applications Key points Accurate and reliable Level measurement under changing process conditions with Dynamic Vapor Compensation Meeting the extreme temperature and pressure challenges with robust probe design and multiple layers of protection Low maintenance with no moving parts to freeze or stick Introduction This document describes the advantages of Using a Rosemount 5300. Series Guided Wave Radar (GWR) with Dynamic Vapor Compensation in high pressure saturated steam applications , such as boiler drums, high pressure feedwater heaters and steam separators. GWR is used for direct Level measurement and is completely independent of density.
4 Technical Note 00840-0100-4530, Rev DB Using GWR for Level in High Pressure Steam Applications October 2016 Using GWR for Level in High Pressure Steam Applications
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
100DHPTM CCI DRAG Control Valve For High Pressure, Control Valve for High Pressure, Pressure, Control, Low, Medium & High Pressure Filters, High, High Pressure, Talk about High Blood Pressure and Stroke, High blood pressure, Blood pressure, ULTRA HIGH-PRESSURE FIREFIGHTING PRODUCTS, Electronic Pressure Control with DIsplay, Electronic Pressure Control with Display Product/Technical Bulletin, Modern High Pressure Die-casting Processes, Significance of Reliable Pressure Control in Oilfield, Air Driven, High Pressure Liquid Pumps