13 Ferrite Toroids provide an often convenient and veryeffective shape for many wide band, pulse and powertransformers and inductors. The continuous magneticpath yields the highest effective permeability and lowestflux leakage of any Considerations :The inductance may be calculated from(the units are in CGS system which is used throughoutthis catalog). Here le and Ae are the effective magneticpath length and cross sectional area of the core, is theeffective permeability of the material, and N is thenumber of turns.
13 Ferrite toroids provide an often convenient and very effective shape for many wide band, pulse and power transformers and inductors. The continuous magnetic