VICKERS Proportional Valves Proportional Pressure …

KCG-6 Valve with Type U Coil ConnectionThis product has been designed and tested to meet specific standards outlined in the European ElectromagneticCompatibility Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5. Forinstructions on installation requirements to achieve effective protection levels, see this leaflet, the InstallationWiring Practices for VICKERS Electronic Products leaflet 2468 and leaflet 02-123931A which is packed with everyKA valve. Wiring practices relevant to this Directive are indicated by Electromagnetic Compatibility (EMC).GB-2324 DRevised 10/97K(A)CG-6/8, 1* SeriesBasic CharacteristicsMax. pressure350 bar (5000 psi).. Max. flow rate400 L/min (106 USgpm). Mounting face to ISO 6264: For K(A)CG-6AR-06-2-A.. For K(A)CG-8AS-08-2-A.. General DescriptionThese two-stage Pressure relief Valves (based on VICKERS type CG2V valvesfeatured in catalog 2323) offer extensiveapplication possibilities through theirability to control the Pressure setting inproportion to an applied electrical input(up to a Pressure limit which is manuallyadjustable and lockable).

KCG-6 Valve with Type “U” Coil Connection This product has been designed and tested to meet specific standards outlined in the European Electromagnetic