Visual Guide to the Accessibility Checklists Part I: Uniform Federal Accessibility Standard (UFAS) UFAS contains the design requirements deemed to comply with Section 504 of the Rehabilitation Act of 1973. The implementation date for the Agency was June 10, 1982. For the full text of UFAS, see: This Guide is not intended to address all Accessibility requirements of any Federal, State or local laws or regulations, nor should this information be relied on for that purpose. To ensure full compliance, borrowers, architects, agency officials, contractors and other interested persons should refer to the Uniform Federal Accessibility Standards and all other applicable Federal, State and local standards. The Owner(s) of the property are responsible for compliance with all applicable Accessibility regulations.
Diagram (a) Front Approaches -- Swinging Doors. Front approaches to pull side of swinging doors shall have maneuvering space that extends 18 in (455 mm) minimum beyond the latch side of the door and 60 in (1525 mm) minimum perpendicular to the doorway. Front approaches to push side of swinging doors, equipped with both closer and latch, shall