PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: bachelor of science

Wastewater Math and Excel Equations

2017 IWEA O&M SeminarCindy Fort, & Troy Casey, , April 26th, 2017 Wastewater Math and Excel EquationsHow to Write Equations in Excel Writing Formulas Using: Sum, Average, Round Freeze Panes Easier viewing in large spreadsheets Creating Trend Graphs Allows for Viewing Trends in Large Sets of Data Examples in Excel for Each Upcoming Problem SetReading Plans and Calculating Tank Dimensions Calculate the total volume , in million gallons (MG), for aeration tanks and secondary clarifier Calculate weir length for secondary clarifiers Conversion: 1 cubic foot = gallons (divide by 1 million to get MG!) Total number of: Aeration Tanks: 4 Secondary clarifiers : 4 Refer to handouts for aeration tank and secondary clarifier plan and section view Dimension Formulas: , = 24 2 Excel : =pi()*D^2/4 or =pi()*R^2 , = 2 Excel : =2*pi()*R or =pi()*D , = Excel : =L*W , =2 +2 Excel : =2*L+2*WPlans and Tank volume WorksheetFood to Microorganism Ratio (F:M)Problem:Refer to April MRO Sheet 1 on laptopsWhat is the F:M Ratio for April 5th, 2015?

volume, in million gallons (MG), for aeration tanks and secondary clarifier • Calculate weir length for secondary clarifiers • Conversion: 1 cubic foot = 7.48 gallons (divide by 1 million to get MG!) • Total Number of: • Aeration Tanks: 4 • Secondary Clarifiers: 4 • Refer to handouts for aeration tank and secondary clarifier plan ...

Tags:

  Volume, Number, Clarifiers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of Wastewater Math and Excel Equations

Related search queries