Chartek 7 - AkzoNobel
May 19, 2015 · Chartek 7 is a high performance epoxy intumescent fire protection coating system. DESCRIPTION The product is a high build, two pack material providing excellent durability and combined corrosion and fire protection. Tested and certified by Lloyd's Register (LR) and Det Norske Veritas (DNV) for structural and divisional fire protection. PRODUCT
Download Chartek 7 - AkzoNobel
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Interline 984 - AkzoNobel
international.brand.akzonobel.comA two component, solvent free chemically resistant heavy duty epoxy phenolic tank lining. DESCRIPTION PRODUCT Interline 984 is intended as a lining for the protection of ferrous and non-ferrous substrates (including concrete).
Chartek 1709 - AkzoNobel
international.brand.akzonobel.comNov 20, 2017 · Airless Spray Airless Spray Thinner Cleaner Work Stoppages Clean Up Trowel Suitable Typically thinned by up to 5% solvent 15°C (59°F) 25°C (77°F) The above figures are for trowel application. Working pot life is not applicable for plural airless spray application as the product is only mixed at the spray gun, at the point of application.
ISO12944 - AkzoNobel
international.brand.akzonobel.comISO12944 is the industry standard for corrosion protection of steel structures by protective paint systems. Originally released in 1998, the standard is put together by representatives from key countries and companies ... All offshore systems must continue to go through 4,200 hours of cycling testing, which equates to 25 weeks.
Epoxy Zinc-Rich
international.brand.akzonobel.comMay 16, 2017 · A two component, metallic zinc rich epoxy primer which complies with the composition and performance requirements of SSPC Paint 20. PRODUCT DESCRIPTION As a high performance primer to give maximum protection as part of any anti-corrosive coating system for aggressive environments including those found on offshore structures, petrochemical
Interzinc - AkzoNobel
international.brand.akzonobel.comNov 23, 2016 · Inorganic Zinc-Rich Silicate Prior to overcoating, Interzinc 22 must be clean, dry and free from both soluble salts and excessive zinc corrosion products. Surface temperature must always be a minimum of 5°F (3°C) above dew point. When applying Interzinc 22 in confined spaces, ensure adequate ventilation.
Epoxy - AkzoNobel
international.brand.akzonobel.comJun 27, 2017 · A two component epoxy anti-corrosive primer pigmented with zinc phosphate. PRODUCT DESCRIPTION For use on properly prepared surfaces in both new construction situations and as an industrial maintenance primer for a wide range of anti-corrosive coatings systems for use in the offshore, petrochemical, chemical, pulp and paper and bridge industries.
Rapid Recoat Epoxy - AkzoNobel
international.brand.akzonobel.comSep 22, 2015 · A two component epoxy zinc phosphate/micaceous iron oxide primer, formulated on proprietary polymer technology, which provides rapid cure and overcoating even under low temperature conditions. A high solids, low VOC product. PRODUCT DESCRIPTION As a primer for steelwork intended for use in a wide range of aggressive environments, including
Intercure 200HS - AkzoNobel
international.brand.akzonobel.comSep 22, 2015 · This product is intended for use only by professional applicators in industrial situations in accordance with the advice given on this sheet, the Material Safety Data Sheet and the container(s), and should not be used without reference to the Material Safety Data Sheet (MSDS) which International Protective Coatings has provided to its customers.
Interzone 954 - AkzoNobel
international.brand.akzonobel.comAug 21, 2017 · Interzone 954 may be applied to suitably sealed or primed concrete; contact International Protective Coatings for further advice on specification and primers. Interzone 954 can be used as a non-skid deck system by modification with addition of GMA132 (crushed flint) aggregate. Application should then be to a suitably primed surface.
Interthane 990 - AkzoNobel
international.brand.akzonobel.comApr 27, 2015 · Warning: Contains isocyanate. Wear air-fed hood for spray application. SAFETY PRECAUTIONS PACK SIZE Unit Size Part A Part B Vol Pack Vol Pack For availability of other pack sizes, contact International Protective Coatings. 20 litre 17.14 litre 20 litre 2.86 litre 3.7 litre 5 US gal 4.29 US gal 5 US gal 0.71 US gal 1 US gal SHIPPING WEIGHT (TYPICAL)
Related documents
Chartek 1709 - AkzoNobel
international.brand.akzonobel.comNov 20, 2017 · Chartek 1709 is a high performance epoxy intumescent fire protection coating system. DESCRIPTION The product is a high build, two pack material providing excellent durability and combined corrosion and fire protection. ANSI/UL 1709 tested and Exterior Listed by Underwriters Laboratories (UL) for fire durations up to 4 hours.
DC315 Intumescent Coating
painttoprotect.comDC315 is a single component, water based intumescent coating tested to meet Building Code requirements for the fire protection of Spray Polyurethane Foam (SPF). Tested and evaluated in the USA by UL and ICC-ES, and in Canada by ULC and CCMC. DC315 is fully AC456 Compliant and satisfies the International
DC315 Intumescent Coating - mystagingwebsite.com
painttoprotect.comDC315 is a single component, water based intumescent coating tested to meet Building Code requirements for the fire protection of for Spray Polyurethane Foam (SPF). Tested and evaluated in the USA by UL and ICC-ES, and in Canada by ULC and CCMC. DC315 is fully AC456 Compliant and satisfies the International
The New Categorized Approach to Architecturally Exposed ...
www.aisc.orgintumescent coating. Note that the intumescent coating itself does not come in different colors; a separate paint is applied on top of the coating. And if an intumescent-coated piece of steel is placed next to an uncoated piece, the final paint colors will vary, as the intumescent coating acts as a different kind of primer.
Central Data Bank List of Building Materials
www.bd.gov.hkIntumescent Coating Protection of steel columns up to 1 hr. FRP. BS 476: Parts 20 & 21: 1987 : N/A : The Loss Prevention Council : TE5944 : November 1986 : N/A : No-objection letter 18/01/2005 : issued in 1990. Required thickness of fire-resisting material should be in accordance with the test report no. TE5944. BD-FP 015 : Glulite Fire ...
MAIN TYPES OF PAINT USED WITH STEEL: STANDARDS ...
www.canam-construction.comand certain types of intumescent coatings. Ideally, the application of a top coat should be done on the job site to minimize touchups from impacts that occur during transportation. Specialty paints Finishes other than the standard grey alkyd primers described above are commonly referred to as specialty paints.
Interior Finishes and Passive Fire Protection
www.ifsta.orgIntumescent Coating — Coating or paintlike product that expands when exposed to the heat of a fire; creates an insulating barrier that protects the material underneath. Mastics – Heat resistant construction adhesive that bonds with most materials; can be used as a fire retardant coating.
Best Practice Guide for Passive Fire Protection for ...
www.ul.comFigure 1 – Steelwork Fire Protected By Intumescent Coating System (Photo Courtesy Of Sherwin-Williams) 1. INTRODUCTION Use of This Guide This guide is intended to assist regulatory authorities, designers and installers in determining the suitability of fire protective products and systems for structural steelwork in a particular