Cladding Hiland Interlock Design Guide - Stratco
DESIGN CONSIDERATIONS Interlock sheeting shall be installed continuous over two spans minimum and restrained to timber supports or metal studs or battens with a minimum base metal thickness (BMT) of 0.55mm. The Quick Selection Guide has been prepared based on loading imposed from wind classification up to and including
Download Cladding Hiland Interlock Design Guide - Stratco
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
STRATCO FRONTIER ASSEMBLY INSTRUCTIONS.
www.stratco.com.au7.0BARGECAPPING Only the front and two sides of the carport require the attachment of barge capping. The rear has the gutter attached. Fix the side barge capping first.
INSULATED ROOFING, - stratco.com.au
www.stratco.com.auCOOLDEK® ROOFING INSULATED PATIO ROOFING TABLE 3.0 - SINGLE SPAN WIND CAPACITIES (kPa) SPAN (mm) P r o fi l ePanel Thickness Limit State 1800 …
Purlins & Girts - stratco.com.au
www.stratco.com.au1 The Stratco Capacity Tables have been calculated in accordance with limit state design principles and comply with the Australian/ New Zealand Standard AS/NZS 4600:2005 Cold-formed steel
INSULATED ROOFING,
www.stratco.com.auFor Cooldek roofi ng in attached or freestanding domestic gable patio application, sheet spans shall not exceed those given for one or no open sides. Alternatively, Table 3.0 indicating wind capacities may be used to determine allowable single spans for any application. Spans specifi ed for units with three sides open are suitable for
Cooldek Outback Flat Attached Installation Guide
www.stratco.com.auIt is the builder’s responsibility to ensure any existing structure that an Outback is being attached to is adequately reinforced to accommodate the additional loads imposed by the verandah, patio or carport. Read these instructions thoroughly before starting your project and refer to them constantly during each stage of construction.
OVERFLOW SOLUTIONS - Stratco
www.stratco.com.ausystem (who may be the architect, builder, hydraulic engineer, home owner, roofing or guttering contractor) to design a ... The following overflow solutions provide a measure for continuous overflow for the full length in which the solution is applied.
POST & RAIL FENCING 1300 155 155 SCAN THIS QR CODE TO …
www.stratco.com.auStratco Post & Rail fencing is a traditional and cost e˜ ective form of fencing. Its simple design makes it the ideal choice for a ... Fence capping is placed over the top edge of the fence sheet with the long side of the capping facing the post and rail side of the fence. The capping is slightly tapered to allow for overlapping.
Roller Door - Stratco
www.stratco.com.audoor to be installed and if the headroom is a restricted space. • If the roller door is installed with a headroom greater then those listed in the Headroom Measurements table, the resulting daylight opening will be reduced. • If the roller door is installed significantly below the top of the
Fencing Frameless Glass Catalogue - Sheds | Fencing | Roofing
www.stratco.com.au12mm Fully Frameless Glass flat polished edges 5mm radius corners 01 Stratco Order Code G.O. Order Code Width Sqm Corner Radius Glass Weight KGS ... base plate - 10mm thick 95mm 73mm inner hole diameter 12mm 95mm 73mm 26 11 100 187 127 95 NOT TO SCALE 60 NOT TO SCALE 21 239 111 52 128 52 • Stainless Steel 2205
WIND CLASSIFICATION, - Stratco
www.stratco.com.auN1 (Non-Cyclonic) N/A W28 N2 (Non-Cyclonic) N/A W33 N3 (Non-Cyclonic) C1 (Cyclonic) W41 N4 (Non-Cyclonic) C2 (Cyclonic) W50 N5 (Non-Cyclonic) C3 (Cyclonic) W60 N6 (Non-Cyclonic) C4 (Cyclonic) W70 TERRAIN CATEGORY The wind speed at a structure is infl uenced by the terrain it fl ows over as it approaches the structure. The terrain category
Related documents
Pryda Timber Connectors
www.pryda.com.auProduct design capacities in this guide have been derived from: (a) Results of laboratory tests carried out by or for Pryda Australia (b) Engineering computations in accordance with the relevant Australian Standards, ie: • AS1720.1-2010 Timber Structures. Part 1: Design Methods. this guide. • AS/NZS1170 series Structural Design Actions.
Timber Roof Trusses - TAFE NSW
nsfsakai.nthsydney.tafensw.edu.auadjacent trusses. Solid timber fascia would be a typical example of this. Truss engineer: This is a professional engineer, as specified in the BCA, experienced in the design of nailplated timber truss systems. Valley saddle trusses: These are trusses that are supported on top of other trusses and used to form the roof shape between roof segments.
CROSS-LAMINATED TIMBER - BRE
www.bre.co.ukThe design principles for CLT fall between timber frame and masonry (Figure 4). Like timber, CLT must be placed above the damp-proof level; it will need at least suitable treatment and more likely a protective cladding when used as an external facade. It is also similar to most modern timber-frame buildings in that it is fabricated off site.
BASIC TIMBER DESIGN CONCEPTS FOR BRIDGES
www.dot.state.mn.ustimber design requirements, procedures, and recommendations addressed in this manual. The majority of the timber design requirements in AASHTO are based on the National Design Specification for Wood Construction (NDS). 26 The NDS is the most widely recognized general specification for timber design
Bridge, Basics, Design, Concept, Timber, Basic timber design concepts for bridges, Timber design
Design of timber structures - Swedish Wood
www.swedishwood.com4 Design of timber structures – Volume 3 Preface This is the second revised edition of Design of timber structures Volume 3, Examples published in 2015. Rules and standards change in pace with the development of society, why a publication of this type has to be reviewed regularly.
TIMBER FRAMING - National Park Service
ncptt.nps.govBart Popenoe. I’m engineering the joinery for a timber-framed garage-loft design, 24x28, with a principal rafter-common purlin 12/12 roof and kingpost truss bents with a 24-in. kneewall. I’ve been using the Guild’s Joinery & Design Workbookas well as other texts to educate myself. Everything was going great until I started
wood construction: column design - Texas A&M University
faculty.arch.tamu.eduTimber Construction by Code •light-frame –light loads –2x’s –floor joists –2x6, 2x8, 2x10, 2x12 typical at spacings of 12”, 16”, 24” –normal spans of 20-25 ft or 6-7.5 m –plywood spans between joists –stud or load-bearing masonry walls –limited to around 3 stories –fire safety