COMPARISONS - VitroGlazings.com
Visible Light Reflectance 2 (Btu/hr•ft2•˚F) NFRC U-Value 3 Solar Heat Gain Coefi f ent i c (SHGC)4 Light-to-Solar Gain (LSG)5 Exterior % Interior % Winter Nighttime Winter Argon SOLARBAN® 67 Solar Control Low-E Glass (Continued) SOLARBAN 67 (2) OPTIGRAY + Clear 38 12 15 0.29 0.24 0.24 1.58 SOLARBAN 67 (2) SOLARGRAY + Clear 27 8 15 0.29 0 ...
Download COMPARISONS - VitroGlazings.com
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Vitro Architectural Glass Product Data Sheet
www.vitroglazings.comVitro Architectural Glass Product Data Sheet ... Cradle Certified™ architectural glasses by Vitro Glass, visit vitroglazings.com, or call 1-855-VTRO-GLS (887-6457). ... All performance data calculated using LBNL Window 7.3 software and represents center of glass performance data. For detailed information on the methodologies used to calculate ...
Vitro Architectural Glass Product Data Sheet
www.vitroglazings.comProduct Data Sheet Vitro Architectural Glass Aesthetic Description Solarban® 60 solar control, low-e glass by Vitro Architectural Glass (formerly PPG Glass) was engineered to control solar heat gain, which is essential to minimizing cooling costs. In a standard one-inch insulating glass unit (IGU), Solarban® 60 glass offers an exterior
Sheet, Data, Glass, Architectural, Data sheet, Vitro, Vitro architectural glass, Data sheet vitro architectural glass
Guidelines For Fully Tempered Interior Butt Glazed Fixed ...
www.vitroglazings.comglass. Since glass is perfectly elastic up to the point of failure, when it is deflected from a load, it will return to its original shape after the load is removed. However, glass that is too thin can tremble, shimmer, or deflect excessively even though the fully tempered glass meets design
The Difference Between Structural Silicone Glazing and ...
www.vitroglazings.comTypical structural silicone glazing includes the 2-side or “ ribbon window” appearance (Sketch 1), or 4side to create a totally flush glazed appearance (Sketch 2). Sketches 3 and 4 are - typical details at the vertical and horizontal mullions. Structural Silicone Glazing requires that appropriate consideration be given to a number of
Center of Glass U-Values for Double and Triple Glazed ...
www.vitroglazings.comGlass Units with Solarban® 60 Low-e Glass with 100% Air, Argon, or Krypton, or Mixtures of These Gases Vitro Architectural Glass PAGE 2 OF 4 Glass Technical Document | TD-121 DOUBLE GLAZED INSULATING GLASS WITH SOLARBAN 60 (2) OR (3) Winter Nighttime U-values for various gas fill types Gap Width 100% Air Filled 5% Air / 95% Argon Filled
Related documents
Reflectance in Thin Films - Materion
materion.comThe reflectivity or reflectance (R), of a surface is an intrinsic optical property of a surface. In many optical, electrooptic, telecommunications, solar concentrator and architectural applications, reflectance must either be controlled (reduced or enhanced), or the color of the object changed (e.g., given a “gold” color).
COOL ROOFS - CertainTeed
www.certainteed.comSolar Reflectivity (SR), Thermal Emittance (TE) & Solar Reflectance Index (SRI) Data * Can be used to comply with the 2019 California Title 24 Part 6 Cool Roof Requirements. ** Can be used to comply with Los Angeles County, California Title 31 cool roof requirements for steep-sloped residential construction.
Solar Time, Angles, and Irradiance Calculator: User Manual
aces.nmsu.eduFinally, the reflectance of the ground surrounding the solar panels must be taken into account because sunlight can reflect off of a surface onto a tilted panel and alter the total solar irradiance collected. The local and solar times, as well as the date entered in the previous sheet, are shown in the box above the green cells as a reference.
Energy Conservation Building Code (ECBC)
cdnbbsr.s3waas.gov.inInitial solar reflectance of no less than 0.70 Initial emittanceno less than 0.75 Initial reflectance/emittance may decrease over time, depending on the product, due to aging, dirt, and microbial accumulation. a) Following this recommendation will provide the greatest benefit where cooling energy costs exceed heating costs
ARCHITECTURAL WINDOW FILM SPECIFICATIONS
suntekfilms.comSOLAR FILMS *IRER is a more complete measurement of heat experienced from solar infrared radiation (780-2500nm) including absorbed and re-radiated energy. **SIRR is a measurement of solar infrared radiation (780-2500nm) not directly transmitted through glass. ***Based on data obtained during product development and subject to change.
Landsat 8 Collection 2 (C2) Level 2 Science Product (L2SP ...
d9-wret.s3.us-west-2.amazonaws.com1.1.1 Surface Reflectance Landsat 8 Surface Reflectance (SR) Science Products are generated from specialized software called Land Surface Reflectance Code (LaSRC). The original LaSRC algorithm was developed by Dr. Eric Vermote, National Aeronautics and Space Administration
Energy Interactions with Atmosphere and Earth Surface
civil.iisc.ernet.inThe reflectance characteristics of earth surface features may be quantified by measuring the portion of incident energy that is reflected. This is measured as a function of wavelength, and is called spectral reflectance, R .
Earth, With, Energy, Interactions, Atmosphere, Reflectance, Energy interactions with atmosphere and earth