Floor Drain Technical Data
Drains) ratings are as follows. These are static lioad ratings and do not take into con- ... •LIGHT DUTY: All grates/covers having a safe live load under 2,000 lbs. (900 KG). ... be 1 1/2 times the transverse area of the connecting pipe. See Table 1. The number and location of drains are determined by the Design Professional
Download Floor Drain Technical Data
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
SMITH JAY R. LOCATION SMITH MFG. CO. ASPE
www.jrsmith.comTitle: 9895, 6" Wide Klassikdrain® Drain System with Integral Metal Rail Author: Jay R. Smith Mfg. Co. Subject: 9895, 6" Wide Klassikdrain® Drain System with Integral Metal Rail, built by Jay R. Smith Mfg. Co.
STAINLESS STEEL DRAINAGE PRODUCTS - jrsmith.com
www.jrsmith.comSMITH STAINLESS STEEL DRAINAGE PRODUCTS Index SMITH STAINLESS STEEL DRAINAGE PRODUCTS Introduction Stainless Steel – The Ultimate Material Stainless steel is one of the most popular and widely used
5519, Guardian Dual Check, 1/4 Turn Non-Freeze Wall ...
www.jrsmith.comTitle: 5519, Guardian Dual Check, 1/4 Turn Non-Freeze Wall Hydrant with Automatic Draining Integral Vacuum Breaker, Dual Check Valve and Stainless Steel Box
SMITH JAY R. U M B IN G AN DRAINAG LOCATION P L E …
www.jrsmith.comTitle: 1330, 1340 General Purpose Roof Drains, 8 1/2" DIA. Low Profile Dome Author: Jay R. Smith Mfg. Co. Subject: 1330, 1340 General Purpose Roof Drains, 8 1/2" DIA.
For WALL HUNG FIXTURES BY KOHLER - Jay R. Smith Mfg. Co.
www.jrsmith.comsmith fixture support selection guide for wall hung fixtures by jay r. smith mfg. co.® member of morris group international post office box 3237 montgomery, alabama 36109-0237 (usa)
HYDRANTS - jrsmith.com
www.jrsmith.comCSI MasterFormat Guide Specification for Hydrants..... 30-32 JAY R. SMITH MFG. CO. 800.467.6484 www.jrsmith.com. 1 Commercial Boxed Wall Hydrants 6” STAINLESS STEEL DIAMETER CORED HOLE BOX TYPE QUARTER TURN NON-FREEZE WALL HYDRANT WITH CONCEALED HOSE CONNECTION FIG. # 5509QT-R ...
Roof Drains Technical Data - jrsmith.com
www.jrsmith.comflange will have a minimum 4" width with a 3/16" lip at drain body. If water - proof deck covering thickness is greater (or less) than 3/16”, lip dimension must be specified. Roughing dimensions of the body must be adjusted accordingly. Drain body should be set low enough to permit "dimpling" of area surrounding drain. Deck Covering Slab ...
LINT INTERCEPTOR
www.jrsmith.comdryers) gradually erode fabrics. Besides these small particles of fabric, there are buttons, string, paper, solid items left in pockets, debris, and mud/dirt ... as an SQ and special pricing. 8910 Series - 4 - is installed at the low end of a poured-in-place concrete trough.
TRAP PRIMERS, TRAP PRIMER ADAPTERS, DISTRIBUTION …
www.jrsmith.comTHREADED CONNECTIONS FIGURE NO. 281-T 3/4” X 1 1/2” NPT THREADED CONNECTIONS FIGURE NO. 281-S 3/4” X 1 1/2” SWEAT CONNECTIONS AIR GAP FITTINGS AIR GAP FITTINGS FEATURES: n Required by code for protection against backflow into the potable water system n Optional finish is nickel plated brass An air gap is a vertical break …
SMITH JAY R. LOCATION V SMITH MFG. CO. POST OFFICE …
www.jrsmith.comFLOOR OR SHOWER DRAINS WITH ADJUSTABLE STRAINER HEADS REGULARLY FURNISHED: Duco Cast Iron Body with Flashing Collar and Adjustable Strainer Head as Indicated by Suffix Letter Selected. Fig. 2010C . . . . . (A) ROUND TOP Fig. 2010C . . . . . (B) SQUARE TOP CAULK OUTLET 2010, 2015 2010, 2015 CR 5-17-85 NONE S2010, 2015 A …
Related documents
FLOOR AND AREA DRAINS - Watts
media.wattswater.comDrains should be specified with sufficient grate free area and outlet size to pass anticipated flow. For most indoor applications, the grate free area should equal 1-1/2 times the transverse area of the connecting pipe.
Kitchen Standard Operating Procedures (SOPs) - James …
jamessprunt.eduthe drains. 10.Any standing water is a place for germs to grow. Users are responsible to insure that there are no puddles of water anywhere in the kitchen at the end of their shifts. Use the squeegee to push all water under the sinks into the floor drains. Be sure to remove all food particles on the floor or around the drain grates.
Operating, Standards, Procedures, Nidra, Kitchen, Great, Kitchen standard operating procedures
R11 Stormwater Drainage - Transport for NSW
roads-waterways.transport.nsw.gov.au2.7.1 . Material for bed and haunch zones at pipe connections mandated to be flowable fill. Ed 4/Rev 0 . Global . Clauses rearranged and reworded. GM, IC . 26.09.12 ; 2.1 . Heading retitled “Concrete Components – General”. 2.1.2, 2.5.3 . Markings requirements for precast concrete members in clause 2.5.3 consolidated with marking ...
Chapter 7 Street, Inlets, and Storm Drains - UDFCD
udfcd.orgChapter 7 Streets, Inlets, & Storm Drains January 2016 Urban Drainage and Flood Control District 7-1 Urban Storm Drainage Criteria Manual Volume 1
DRAINS TO FRESH WATER
wisconsindot.govDRAINS TO FRESH WATER DUMP NO WASTE 1 2" HIGH RAISED LETTERS FLUSH WITH TOP SURFACE DRAINS TO FRESH WATER DUMP NO WASTE DRAINS TO FRESH WATER DUMP NO WASTE 1" DIAGONAL BARS ... Inlet Covers Type MS and MS-A are to be placed on Inlet Median 1, 2, 3, or 4 Grates. Inlet Covers Type WM is placed on Inlets and Catch Basins …