HILTI TECHNICAL BULLETIN
Mar 04, 2018 · Table 1 – Hilti HIT-HY 270 allowable adhesive bond tension loads for threaded rods and reinforcing bars in the face of grout-filled concrete masonry walls1,2,3,4,5,6,7,8 Nominal anchor diameter c in. Rebar size Effective embedment in. (mm)11 cr Tension lb (kN) Spacing9 10Edge distance Critical s cr in. (mm) Minimum min Load reduction factor ...
Download HILTI TECHNICAL BULLETIN
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Page 1/8 Safety Data Sheet acc. to ISO 11014 - Hilti USA
www.hilti.comPage 2/8 Safety Data Sheet acc. to ISO 11014 Printing date 05/19/2015 Version number 5 Reviewed on 05/19/2015 (Contd. of page 1) 40.2.7 H319 Causes serious eye irritation.
Sheet, Data, Safety, Pages, Page 1, Hilti, 8 safety data sheet acc
Hilti. Outperform. Outlast.
www.hilti.comSelector Guide Through-Penetration Joint Reference Data Firestop Mortar (CP 637) Product description ... Concrete and masonry assemblies Expansion on setting (approx.)Walls and floors rated up to 4 hours ... Mix ratio (recommended, mortar to water):
ICC-ES Evaluation Report ESR-2269 - Hilti
www.hilti.com1.0 EVALUATION SCOPE Compliance with the following codes: 2018, 2015, and 2012 International Building Code ® (IBC) 2018, 2015, and 2012 International Residential Code® (IRC) For evaluation for compliance with codes adopted by the Los Angeles Department of Building and Safety (LADBS), see ESR-2269 LABC and LARC Supplement.
Report, Evaluation, Hilti, 2269, Icc es evaluation report esr 2269
HIT-RE 500 V3 - Hilti
www.hilti.comSafety information for 2-Component-products 18/06/2020 US-OSHA - en 2/27 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If skin irritation or rash occurs: Get medical advice/attention. If eye irritation persists: Get medical advice/attention.
Hilti HIT-HY 200 with HIT-V
www.hilti.comAnchor rods HIT-V GR / -HCR) are available in variable length MIO M12 TE 16 M16 M20 M24 TE 40 M27 - TE 70 M30 compressed air gun or blow out pump, set of cleaning brushes, dispenser Drill hole to the required embedment depth with an appropriately sized Hilti TE-CD Or TE-YD hollow drill bit with Hilti vacuum attachment. This drilling
With, Anchor, Rods, Hilti, Anchor rods, Hilti hit hy 200 with hit
Hilti HIT-HY 200 with rebar
www.hilti.comHilti HIT-HY 200 with rebar Benefits - suitable for cracked and non- cracked concrete C 20/25 to C 50/60. - Approved automatic cleaning with the use of the hollow drill-bit high loading capacity, excellent handling HY 200-R version with extended curing time for rebar applications small edge distance and anchor spacing possible
KB-TZ2 TECHNICAL GUIDE
www.hilti.comKB-TZ2 Technical uide April 2021 5 Table 4 - Allowable Hilti carbon steel KB-TZ2 strength in uncracked concrete for hammer drill and core drill installations 1,2,3,4 Nominal anchor
OPENINGS IN COMPOSITE FLOOR DECKS - Hilti
www.hilti.comin-situ reinforced concrete topping. The decking not only acts as a permanent formwork to the concrete, but also provides sufficient shear bond with the concrete so that, when the concrete has cured, the two materials act together compositely to resist the loads on the deck. Openings in floor decks are a common part of any building.
HIT-1 ADHESIVE ANCHORING SYSTEM - Hilti
www.hilti.comHIT-1 ADHESIVE ANCHORING SYSTEM Technical Supplement PRODUCT DESCRIPTION Hilti HIT-1 is a hybrid adhesive mortar combining resin, hardener, cement, and water. It’s formulated for fast curing and easy installation in a wide range of concrete and masonry base materials with temperatures ranging from 32°F (0°C) up to 95°F (35°C).
ICC-ES Evaluation Report ESR-4266
www.hilti.comDesign strength of anchors complying with the 2012 IBC as well as Section R301.1.3 of the 2012 IRC, must be determined in accordance with ACI 318-11 Appendix D and this report. Design parameters provided in Table 4, Table 5, Table 6 and Table 7 of this report are based on the 2021 IBC (ACI 318-19), 2018 and 2015 IBC (ACI 318-14) and the 2012 IBC
Related documents
UNIFORM STANDARD DETAILS for PUBLIC WORKS …
azmag.gov302-1 1998 joint restraint with tie rods (drawing) 302-2 1998 joint restraint with tie rods (notes) 303-1 1998 joint restraint for ductile iron and polyethylene ... 381 1998 anchor blocks for vertical bends 389 2001 curb stop with valve box and cover 390 1998 curb stop with flushing pipe
Standards, Public, Details, Uniform, Work, Anchor, Rods, Uniform standard details for public works
ANSI/AISC 360-16 Specification for Structural Steel Buildings
www.aisc.orgPREFACE 16.1-v Specification for Structural Steel Buildings, July 7, 2016 AMERICAN INSTITUTE OF STEEL CONSTRUCTION The Committee honors former members, David L. McKenzie, Richard C. Kaehler and Keith Landwehr, and advisory member, Fernando Frias, who passed away during this cycle.
steelwise - AISC
www.aisc.orgthreaded steel anchor rods (anchor bolts), used with nuts, for diameters, D, from 0.5 in. to 4 in. Internal threads (nuts) or external threads (threaded rod) could strip under certain conditions. This limit state can usu-ally be avoided by having a suitable type of nut fully engaged
COMMONWEALTH OF PENNSYLVANIA
www.dot.state.pa.usfor anchor bolts, see sheet 3. 7. for quantity, size, size of holes and bolt circle project-by-project basis. overlap slip joint is specified or approved on a except for round stepped supports, or unless alternate use one-piece strain pole when luminaire is required span wire. 6. provide dead-ends that develop the strength of the 1.
Hilti HIT-HY 200 with HIT-V
www.hilti.comAnchor rods HIT-V GR / -HCR) are available in variable length MIO M12 TE 16 M16 M20 M24 TE 40 M27 - TE 70 M30 compressed air gun or blow out pump, set of cleaning brushes, dispenser Drill hole to the required embedment depth with an appropriately sized Hilti TE-CD Or TE-YD hollow drill bit with Hilti vacuum attachment. This drilling
With, Anchor, Rods, Hilti, Anchor rods, Hilti hit hy 200 with hit