COOLDEK® ROOFING INSULATED ROOFING, FIXING RECOMMENDATIONS WE'LL BRING THE Cooldek roofi ng should be laid into the prevailing wind and sit neatly on the preceding roof sheet. For Classic profi le fasten through each crest and for CGI profi le fasten through every second crest. Use cyclone caps and neoprene washers in all crest fi xings.
Download INSULATED ROOFING, - Stratco
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
STRATCO FRONTIER ASSEMBLY INSTRUCTIONS.
www.stratco.com.au7.0BARGECAPPING Only the front and two sides of the carport require the attachment of barge capping. The rear has the gutter attached. Fix the side barge capping first.
Purlins & Girts - stratco.com.au
www.stratco.com.au1 The Stratco Capacity Tables have been calculated in accordance with limit state design principles and comply with the Australian/ New Zealand Standard AS/NZS 4600:2005 Cold-formed steel
INSULATED ROOFING,
www.stratco.com.auFor Cooldek roofi ng in attached or freestanding domestic gable patio application, sheet spans shall not exceed those given for one or no open sides. Alternatively, Table 3.0 indicating wind capacities may be used to determine allowable single spans for any application. Spans specifi ed for units with three sides open are suitable for
Cooldek Outback Flat Attached Installation Guide
www.stratco.com.auIt is the builder’s responsibility to ensure any existing structure that an Outback is being attached to is adequately reinforced to accommodate the additional loads imposed by the verandah, patio or carport. Read these instructions thoroughly before starting your project and refer to them constantly during each stage of construction.
OVERFLOW SOLUTIONS - Stratco
www.stratco.com.ausystem (who may be the architect, builder, hydraulic engineer, home owner, roofing or guttering contractor) to design a ... The following overflow solutions provide a measure for continuous overflow for the full length in which the solution is applied.
POST & RAIL FENCING 1300 155 155 SCAN THIS QR CODE TO …
www.stratco.com.auStratco Post & Rail fencing is a traditional and cost e˜ ective form of fencing. Its simple design makes it the ideal choice for a ... Fence capping is placed over the top edge of the fence sheet with the long side of the capping facing the post and rail side of the fence. The capping is slightly tapered to allow for overlapping.
Roller Door - Stratco
www.stratco.com.audoor to be installed and if the headroom is a restricted space. • If the roller door is installed with a headroom greater then those listed in the Headroom Measurements table, the resulting daylight opening will be reduced. • If the roller door is installed significantly below the top of the
Fencing Frameless Glass Catalogue - Sheds | Fencing | Roofing
www.stratco.com.au12mm Fully Frameless Glass flat polished edges 5mm radius corners 01 Stratco Order Code G.O. Order Code Width Sqm Corner Radius Glass Weight KGS ... base plate - 10mm thick 95mm 73mm inner hole diameter 12mm 95mm 73mm 26 11 100 187 127 95 NOT TO SCALE 60 NOT TO SCALE 21 239 111 52 128 52 • Stainless Steel 2205
WIND CLASSIFICATION, - Stratco
www.stratco.com.auN1 (Non-Cyclonic) N/A W28 N2 (Non-Cyclonic) N/A W33 N3 (Non-Cyclonic) C1 (Cyclonic) W41 N4 (Non-Cyclonic) C2 (Cyclonic) W50 N5 (Non-Cyclonic) C3 (Cyclonic) W60 N6 (Non-Cyclonic) C4 (Cyclonic) W70 TERRAIN CATEGORY The wind speed at a structure is infl uenced by the terrain it fl ows over as it approaches the structure. The terrain category
SUPERDEK - Stratco
www.stratco.com.auRoofing calculations are based on Cpe=-0.9 and Cpi=0.2, walling is based on Cpe=-0.65 and Cpi=0.2. A local pressure factor, Kl=2.0 has been used for all roofing spans for both strength and serviceability limit states. Roof spans take into consideration loads incidental to maintenance. All pressures have been determined assuming wind
Related documents
Roofing Criteria - NC
files.nc.govThis criteria for roofing design is a compilation of data, policies, legal aspects, preferences, experiences, prejudices, etc. that a Designer may find useful and necessary in designing roofs and roofing systems and preparing contract documents relative to roofing of State owned buildings. This criteria is not a compendium of all roofing knowledge.
Electrical Hazards - Occupational Safety and Health ...
www.osha.govElectrical hazards can be found in nearly every roofing work site. Whether the hazard is posed by worn or damaged power tools or cords, improperly grounded tools or equipment, or the presence of standing water, it is the responsibility of the contractor to make sure the tools and equipment
LANDMARK SERIES - CertainTeed
www.certainteed.comyou can coordinate flat roof areas like carports, canopies and porches with your main roof. Flintlastic SA is a self-adhering low slope roofing product available in ten colors that complement some of the most popular CertainTeed shingles. Color Companion Products for Flat Roof Areas 19
Standard Details for Metal Roofing & Siding
www.bestmaterials.comagainst the metal. Nail placement must be in the ribs for roofing ap-plications to minimize the potential for roof leaks. Over-driving the nail can split the washer and dimple the metal, causing leaks. Wood screws with combination metal and neoprene washers should be installed in the flat area of the panel adjacent to the ribs, and
CHAPTER 10 FLASHING - asphaltroofing.org
asphaltroofing.orgover the shingle and vent pipe. Place the flange over the pipe to lay flat on the roof as shown in Figures 10-5a and 10-5b. Inspections should be performed once a year to check for cracks in the flange. A variety of boot styles are available on the market, so refer to the flashing manufacturer's installation instructions.