INSULATED ROOFING, - Stratco
INSULATED PATIO ROOFING MATERIAL SPECIFICATIONS NOTE: IF values are shown in brackets they represent the maximum allowable span if an overhang is used. The cladding back span shall be no less than 1.5 times the deck overhang. TABLE 2.0 - SINGLE SPANS (mm) - Domestic Patio Application COOLDEK CLASSIC Open Sides Panel Thickness
Download INSULATED ROOFING, - Stratco
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
STRATCO FRONTIER ASSEMBLY INSTRUCTIONS.
www.stratco.com.au7.0BARGECAPPING Only the front and two sides of the carport require the attachment of barge capping. The rear has the gutter attached. Fix the side barge capping first.
Purlins & Girts - stratco.com.au
www.stratco.com.au1 The Stratco Capacity Tables have been calculated in accordance with limit state design principles and comply with the Australian/ New Zealand Standard AS/NZS 4600:2005 Cold-formed steel
INSULATED ROOFING,
www.stratco.com.auFor Cooldek roofi ng in attached or freestanding domestic gable patio application, sheet spans shall not exceed those given for one or no open sides. Alternatively, Table 3.0 indicating wind capacities may be used to determine allowable single spans for any application. Spans specifi ed for units with three sides open are suitable for
Cooldek Outback Flat Attached Installation Guide
www.stratco.com.auIt is the builder’s responsibility to ensure any existing structure that an Outback is being attached to is adequately reinforced to accommodate the additional loads imposed by the verandah, patio or carport. Read these instructions thoroughly before starting your project and refer to them constantly during each stage of construction.
OVERFLOW SOLUTIONS - Stratco
www.stratco.com.ausystem (who may be the architect, builder, hydraulic engineer, home owner, roofing or guttering contractor) to design a ... The following overflow solutions provide a measure for continuous overflow for the full length in which the solution is applied.
POST & RAIL FENCING 1300 155 155 SCAN THIS QR CODE TO …
www.stratco.com.auStratco Post & Rail fencing is a traditional and cost e˜ ective form of fencing. Its simple design makes it the ideal choice for a ... Fence capping is placed over the top edge of the fence sheet with the long side of the capping facing the post and rail side of the fence. The capping is slightly tapered to allow for overlapping.
Roller Door - Stratco
www.stratco.com.audoor to be installed and if the headroom is a restricted space. • If the roller door is installed with a headroom greater then those listed in the Headroom Measurements table, the resulting daylight opening will be reduced. • If the roller door is installed significantly below the top of the
Fencing Frameless Glass Catalogue - Sheds | Fencing | Roofing
www.stratco.com.au12mm Fully Frameless Glass flat polished edges 5mm radius corners 01 Stratco Order Code G.O. Order Code Width Sqm Corner Radius Glass Weight KGS ... base plate - 10mm thick 95mm 73mm inner hole diameter 12mm 95mm 73mm 26 11 100 187 127 95 NOT TO SCALE 60 NOT TO SCALE 21 239 111 52 128 52 • Stainless Steel 2205
WIND CLASSIFICATION, - Stratco
www.stratco.com.auN1 (Non-Cyclonic) N/A W28 N2 (Non-Cyclonic) N/A W33 N3 (Non-Cyclonic) C1 (Cyclonic) W41 N4 (Non-Cyclonic) C2 (Cyclonic) W50 N5 (Non-Cyclonic) C3 (Cyclonic) W60 N6 (Non-Cyclonic) C4 (Cyclonic) W70 TERRAIN CATEGORY The wind speed at a structure is infl uenced by the terrain it fl ows over as it approaches the structure. The terrain category
SUPERDEK - Stratco
www.stratco.com.auRoofing calculations are based on Cpe=-0.9 and Cpi=0.2, walling is based on Cpe=-0.65 and Cpi=0.2. A local pressure factor, Kl=2.0 has been used for all roofing spans for both strength and serviceability limit states. Roof spans take into consideration loads incidental to maintenance. All pressures have been determined assuming wind
Related documents
A GUIDE TO INSULATED HVAC DUCT SYSTEMS
insulationinstitute.orgFibrous glass insulated flexible ducts can be used in applications where internal air temperatures do not exceed 250°F (121°C). Fibrous glass insulated flexible ducts systems are manufactured to comply with Air Diffusion Council Test Code FD-72-R1. They also meet requirements of UL181, and comply with all widely used model building codes.
Cable UniHome Housing Cable - Marine Cables - PVC ...
www.ucable.com.myB ) XLPE INSULATED EXTRA HIGH VOLTAGE POWER CABLES CABLE STRUCTURAL DESCRIPTION AND CONSTRUCTION DATA XLPE Insulated Copper Wire Screened Cable - 76/132 (145) kVTo IEC60840 andTenaga National Berhad (TNB) Specification.....62-63 XLPE Insulated Corrugated Aluminium Sheathed Cable - 160/275 (300) kV to IEC62067
Switchgear Type 8DJH for Secondary Distribution Systems up ...
assets.new.siemens.comApplication ypical T uses 2 Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kV, Gas-Insulated · Siemens HA 40.2 · 2017 R-HA40-111.tif R-HA40-112.tif R_HA40-150a tif Application in public and industrial energy systems R_HA40_160 tif R-HA40-110.tif R-HA40-157 tif
IS 694 (2010): POLYVINYL CHLORIDE INSULATED …
law.resource.org450/750 V — Part 3: Non-sheathed cables for fixed wiring IEC 60227-3-am1 (1997-07) Ed. 2.0 Amendment 1 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V — Part 3: Non-sheathed cables for fixed wiring IEC 60227-4 (1997-12) Ed. 2.1 Polyvinyl chloride insulated cables of rated voltages up to and including
Sheet 26001 Power Circuit Breakers Insulated-Case ... - Eaton
www.eaton.comInsulated-Case Circuit Breakers, and Molded-Case Circuit Breakers There are main classifications of low- ... Non-defeatable instantaneous over-ride for high magnitude faults. Selective trip over a smaller range of fault currents within the interrupting rating (low
Solderless terminals RING TONGUE (R type) Non-insulated
www.jst-mfg.comRING TONGUE (R type) Non-insulated. Note:1) Products with the JIS mark conform to JIS C2805.) 2 Please use the die AD-901S for the pneumatic tool YA-4, and the die 8NK-6 for the hydraulic tools YPT-60N/YET-60-1. 3) Delivery lead times may vary depending on the product. Contact JST for details. 4 8 (6.64 to 10.52) 200 500 500
Insulated Garage Door Brochure - Overhead Door
www.overheaddoor.comWindows placed in the bottom section of a door must have DSB 1/8", tempered, or 1/2" insulated glass. Model 5740, Flush panel, Gray finish, Clear Long windows Vertical window option All window option (Flush panel only) Actual glass may vary from brochure photos due to fluctuations in the printing process.
APPENDIX 2 - Current Carrying and Voltage Drop Tables for ...
www.sghcable.comTABLE (2) Multicore PVC insulated cables, non-armoured (COPPER CONDUCTORS) BS6004 / BS6346 / GB5023 / GB/T12706.1 / IEC60227 / IEC60502 Ambient temperature:30oC CURRENT CARRYING CAPACITY (Amperes): Conductor operating temperature:70oC