Lettered Model Numbers - ClimateMaster
1. All units come standard with 100zVA transformer. 2. 208-230 Volt units wired for 208 Volt service 3. Refer to blower performance table in Spec catalog to determine correct Drive Package. 4. Horizontal Units come standard with Filter Rails. Filter Frames ordered as accessories. Vertical Units come standard with Filter Frames.
Download Lettered Model Numbers - ClimateMaster
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Basic - ClimateMaster
files.climatemaster.comESD (Emergency shut down). This is normally connected to Fire alarm input, check for dry contact closure from input at ESD terminal and C. Description of Operation Status LED (Green) Status LED (Green) Status LED (Green) Alarm Relay Normal Mode On - Off Normal Mode with UPS On - Flashing Code 8 Cycle (Closed 5 seconds, open 25 seconds)
Tranquility 16 COMPACT (TC) Series - ClimateMaster
files.climatemaster.com6 limateMaster ater-ource eat Pumps CLIMATEMASTER WATER-SOURCE HEAT PUMPS Tranquility ® Compact (TC) Series Rev.: October 1, 2021 Unit Physical Data Tranquility® 16 (TC) Series (60 Hz) TC Series 006 009 012 015 018 024 030 036 041 042 048 060
Tranquility® 20 (TS) Series - ClimateMaster
files.climatemaster.comPre-Installation - Installation, Operation, and Maintenance instructions are provided with each unit. Horizontal equipment is designed for installation above false ceiling or in a ceiling plenum. Other unit configurations are typically installed in a mechanical room. The installation site chosen should include adequate
Tranquility Compact (TC) Series - ClimateMaster
files.climatemaster.comNov 14, 2017 · meets IECC section C403.3.1 and is a requirement in many states. The Tranquility 16 (TC) Series Water-Source Heat Pumps are designed to meet the challenges of today’s HVAC demands with one of the most innovative products available on the market. UniT FEaTUrES • Sizes 006 (1/2 ton, 1.76 kW) through 060 (5 tons, 17.6 kW)
Tranquility 22 (TZ) Series - ClimateMaster
files.climatemaster.comA homeowner can see and give their dealer the fault code and possible causes to help prepare for a service call. Once on the job, a dealer can see what the operating ... the DXM2 control adjusting the pump speed to maintain an installer-set loop ∆T. By controlling the water flow, the system is able to operate at its optimal capacity and ...
Related documents
Rheem High Efficiency Air Handler - MyRheem.com
pts.myrheem.commum blower performance, operate the unit in the .2" to .5" in. W.C. external static range. In general, the indoor motor speed tap should be as shown in table for the appropriate cooling capacity shown. Always check to make sure proper motor speed tap is connected as units are shipped from the factory connected for high speed operation (Speed ...
Performance, High, Unit, Efficiency, Handlers, Rheem, Rheem high efficiency air handler
High Efficiency Horizontal and Vertical Water-Source ...
www.climas-trane.com.mxHigh Efficiency Horizontal and Vertical Water-Source Comfort System AxiomTM 1/2 - 5 Tons — 60 HZ— Model GEH/GEV ... Performance Data 37 Cool and Heat Performance 38 Correction Factors 62 Electrical Performance 63 ... cooling units. This valve is piped to be energized in the cooling mode to allow
Tranquility Compact (TC) Series - ClimateMaster
files.climatemaster.comNov 14, 2017 · Performance Correction Tables for Units 35 Antifreeze Correction Table 36 Blower Performance Data – TC006 38 ... Horizontal – Dimensional Data 56 TCH - with Waterside Economizer - Dimensional Data 58 ... Options such as tin-plated air coil, DDC controls, and high efficiency pleated MERV rated air filters allow customized
INSTALLATION MANUAL - Dominion Energy
www.questargas.comThese high efficiency, compact units employ induced combustion, reli-able hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applica-tions.
Product Data - Carrier
www.shareddocs.comThe 40RU Series air--handling units are the best choice for packaged air handlers. Model 40RUA units have direct--expansion coils. 40RUS units are chilled water packaged air handling units. All models offer excellent fan performance, a unique combination of indoor air quality features, easy installation, and affordable prices.
Product Data - Carrier
www.shareddocs.comefficiency for high SEER and HSPF performance. Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners. Also units come with solid state fan controls, 1−in (25mm) thick insulation with R−value of 4.2, multi−speed motors, and fully−wettable coils. Units can accommodate factory−
Performance, High, Unit, Coils
Performance Climate Changer™ Air Handlers Sizes 3-120
www.trane.com† Low-leak, high thermal performance casing design † All airfoil-bladed and Traq da mpers meet ASHRAE 90.1 lowest specified leakage requirements † High-efficiency coil fins delive r superior heat transfer while al lowing face velocities in excess of 625 fpm without moisture carryover System Optimization
Product Catalog Packaged Rooftop Air Conditioners ... - Trane
www.trane.comThis switch monitors coil temperature to prevent evaporator icing and protect the compressor. Heat Exchanger The cabinet features a tubular heat exchanger in, low, medium and high heat capacities, all of which are available for both vertical as well as horizontal discharge directions. The heat exchanger is
High, Trane, Horizontal, Coils