MONOBLOCK DIRECTIONAL CONTROL VALVE
Internal leakage A(B)→T ∆p=100 bar -- 1450 psi, fluid and valve at 40°C 3cm3/min 0.18 in3/min Fluid Mineral base oil Fluid temperature with NBR seals from --20°Cto80°C with FPM (VITON) seals from --20°C to 100°C Viscosityy campo di lavoro from 15 to 75 mm2/s from 15 to 75 cSt minima 12 mm 2/s 12 mm /s massima 400 mm 2/s 400 mm /s
Download MONOBLOCK DIRECTIONAL CONTROL VALVE
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
STANDARD TERMS and CONDITIONS FOR THE …
www.walvoil.comM A F G 0 0 2 STANDARD TERMS and CONDITIONS FOR THE SALE of GOODS 1.- INTERPRETATION In these Conditions: a.-“BUYER” means the person whose order of the Goods is accepted by the Seller.
DIVERTER VALVES - Walvoil
www.walvoil.comDiverter valves 2 DGR002E WARNING! All specifications of this catalogue refers to the standard product at this date. Walvoil, oriented to a …
Valves, Diverter valves walvoil, Diverter, Walvoil, Diverter valves
DIVERTER VALVES - Walvoil
www.walvoil.comDiverter valves 2 DGR002A WARNING! All specifications of this catalog refers to thestandard productat this date. Walvoil, oriented to a …
Valves, Diverter valves walvoil, Diverter, Walvoil, Diverter valves
Flow control pressure compensated valves - Walvoil
www.walvoil.comDIVISION DIVISION D1WWEU01E General Information FLOW CONTROL PRESSURE COMPENSATED VALVES Fluid:best use mineral oil with viscosity ranging between 10 and 200 cSt. Filter:dirty oil is the main reason for failure and troubles of hydraulic parts and systems. The table below contains OLEOSTAR S.p.A. recommendations about …
Control, Pressure, Flows, Valves, Compensated, Flow control pressure compensated valves
Pressure relief valves - Walvoil
www.walvoil.comDIVISION DIVISION D1WWEM01E General Information PRESSURE RELIEF VALVES Fluid:best use mineral oil with viscosity ranging between 10 and 200 cSt. Filter:dirty oil is the main reason for failure and troubles of hydraulic parts and systems. The table below contains OLEOSTAR S.p.A. recommendations about the minimum oil contamination …
DPX-HS - walvoil.com
www.walvoil.comWalvoil S.P.A. • 42124 Reggio Emilia • Italy • Via Adige, 13/D • Tel.+39.0522.932411 • Fax +39.0522.300984 www.waloil.com DPX-HS Directional Valve specifically designed
Business Unit Hydrocontrol - Walvoil
www.walvoil.comD1WWA003IE Walvoil S.p.A. • Headquarters Reggio Emilia • Italy Business Unit Hydrocontrol Osteria Grande (BO) • Italy Galtech Site Cavriago (RE) • Italy
COMPACT CATALOGUE - Walvoil
www.walvoil.comWorking conditions Features Simple, compact designed, this valve is only one section for open centre and closed centre hydraulic systems. HFitted with a …
MONOBLOCK DIRECTIONAL CONTROL VALVE - …
www.walvoil.comWorking conditions Filettature standard SD11 4 DAT004A This catalog shows technical specifications and diagrams measured with mineral oil of 46 mm2/s - …
Control, Valves, Directional, Monoblock directional control valve, Monoblock
Distributori Load-Sensing pre-compensati - …
www.walvoil.comDistributori Load-Sensing pre-compensati - Pressure pre-compensated Load-Sensing valves Tipo Type Portata nominale Nominal fl ow Pressione massima
Pressure, Load, Sensing, Compensated, Distributori load sensing pre compensati, Distributori, Compensati, Distributori load sensing pre compensati pressure pre compensated load
Related documents
V60 V63, 3/2, 2 x 3/2, 5/2 or 5/3 Solenoid and pilot ...
cdn.norgren.comSolenoid and pilot actuated spool valves 01/17 ... Inlet orifice 0,8 mm Electrical connection (corresponding to choosen coil) EN 175301-803 - Form B, 22 mm ... NO/NC = 1 valve normally open, 1 valve normally closed (port P) Our policy is one of continued research and development. We therefore reserve the right to amend,
Valves, Solenoid, Pilots, Actuated, Spool, Solenoid and pilot actuated spool valves
Solenoid/pneumatic valves, Tiger Classic
www.festo.comJMFDH Solenoid valve, with armature tube for F solenoid coil, with dominant signal, double solenoid JH Pneumatic double pilot valve JDH Pneumatic double pilot valve with dominant signal VL/O Pneumatic valve, monostable, normally open or closed VL Pneumatic valve, monostable 002 Valve function 3 3/2-way valve 5 5/2-way valve 003 Pneumatic ...
D680 Series Proportional Control Valves with Integrated ...
www.moog.comrecommended 15 to 45 mm2/s allowed 5 to 400 mm2/s System filtration Pilot valve: high pressure filter (without bypass, but with dirt alarm) mounted in the main flow and if possible, directly upstream of the valve. Main stage: high pressure filter as for the pilot stage. In com-
Series, With, Control, Valves, Integrated, Pilots, Proportional, Pilot valve, Series proportional control valves with integrated
ASCO™ Spool Valves NC - 1/4 and 1/2 tapped
www.emerson.com• The same spool valve can be adapted for 3/2 NC or 5/2 functions for controlling double- ... 3/2 NC - 5/2 - Air pilot operated - spring return (monostable) 1/4 6: 0,75 12,5: ... 11 mm, industry standard B, for cables with an outer diameter from 6 to 8 mm
G631 Product Catalog - Moog Inc.
www.moog.comValve design 2-stage, with spool and bushing and dry torque motor Mounting pattern ISO 4401-05-05-0-94 Maximum operating pressure to ports P, T, A, B 315 bar (4,500 psi) Pilot stage Nozzle Flapper Rated flow at
Valve terminal 2 Design The valve terminal VTUG- has the ...
www.festo.comWidths 10 mm and 18 mm Width 14 mm 1 2 2 1 1 Position of the pilot air supply selector or the blanking plug 2 Earth terminal (hole for the earthing screw) Fig. 2 2.1 Valve terminal VTUG-…-M The valve terminal VTUG-...-M (multi-pin node) has the following additional con necting component. 1 1 Electrical multi-pin plug connection (Sub-D or ...
NELES® ND9000 INTELLIGENT VALVE CONTROLLER
www.valin.comDI 15 ms IS 15 ms OS 15 ms Performance with moderate constant-load actuators Dead band: ≤ 0.1 % Hysteresis: < 0.5 % Local User Interface (LUI) functions Local control of the valve Monitoring of valve position, target position, input signal, tem-perature, supply and actuator pressure difference Guided-startup function