Example: marketing
MULTI-STAGE VAPOUR COMPRESSION REFRIGERATION …

MULTI-STAGE VAPOUR COMPRESSION REFRIGERATION …

Back to document page

The high temperature evaporator (Refrigeration capacity 5 TR) of a multi-evaporator VCR system, working with ammonia, is operating at –6oC and the low temperature evaporator (Refrigeration capacity 10 TR) is operating at –34oC. The condenser pressure is 10.99 bar. The system using individual expansion valves for each evaporator.