OVERFLOW SOLUTIONS - Stratco
The design and installation of guttering and downpipe systems needs to comply with the Building Code of Australia and Australian Standards AS/NZS 3500.3 Plumbing and Drainage, Stormwater Drainage. RESPONSIBILITY OF THE INSTALLER It is …
Download OVERFLOW SOLUTIONS - Stratco
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
STRATCO FRONTIER ASSEMBLY INSTRUCTIONS.
www.stratco.com.au7.0BARGECAPPING Only the front and two sides of the carport require the attachment of barge capping. The rear has the gutter attached. Fix the side barge capping first.
INSULATED ROOFING, - stratco.com.au
www.stratco.com.auCOOLDEK® ROOFING INSULATED PATIO ROOFING TABLE 3.0 - SINGLE SPAN WIND CAPACITIES (kPa) SPAN (mm) P r o fi l ePanel Thickness Limit State 1800 …
Purlins & Girts - stratco.com.au
www.stratco.com.au1 The Stratco Capacity Tables have been calculated in accordance with limit state design principles and comply with the Australian/ New Zealand Standard AS/NZS 4600:2005 Cold-formed steel
INSULATED ROOFING,
www.stratco.com.auFor Cooldek roofi ng in attached or freestanding domestic gable patio application, sheet spans shall not exceed those given for one or no open sides. Alternatively, Table 3.0 indicating wind capacities may be used to determine allowable single spans for any application. Spans specifi ed for units with three sides open are suitable for
Cooldek Outback Flat Attached Installation Guide
www.stratco.com.auIt is the builder’s responsibility to ensure any existing structure that an Outback is being attached to is adequately reinforced to accommodate the additional loads imposed by the verandah, patio or carport. Read these instructions thoroughly before starting your project and refer to them constantly during each stage of construction.
POST & RAIL FENCING 1300 155 155 SCAN THIS QR CODE TO …
www.stratco.com.auStratco Post & Rail fencing is a traditional and cost e˜ ective form of fencing. Its simple design makes it the ideal choice for a ... Fence capping is placed over the top edge of the fence sheet with the long side of the capping facing the post and rail side of the fence. The capping is slightly tapered to allow for overlapping.
Roller Door - Stratco
www.stratco.com.audoor to be installed and if the headroom is a restricted space. • If the roller door is installed with a headroom greater then those listed in the Headroom Measurements table, the resulting daylight opening will be reduced. • If the roller door is installed significantly below the top of the
Fencing Frameless Glass Catalogue - Sheds | Fencing | Roofing
www.stratco.com.au12mm Fully Frameless Glass flat polished edges 5mm radius corners 01 Stratco Order Code G.O. Order Code Width Sqm Corner Radius Glass Weight KGS ... base plate - 10mm thick 95mm 73mm inner hole diameter 12mm 95mm 73mm 26 11 100 187 127 95 NOT TO SCALE 60 NOT TO SCALE 21 239 111 52 128 52 • Stainless Steel 2205
WIND CLASSIFICATION, - Stratco
www.stratco.com.auN1 (Non-Cyclonic) N/A W28 N2 (Non-Cyclonic) N/A W33 N3 (Non-Cyclonic) C1 (Cyclonic) W41 N4 (Non-Cyclonic) C2 (Cyclonic) W50 N5 (Non-Cyclonic) C3 (Cyclonic) W60 N6 (Non-Cyclonic) C4 (Cyclonic) W70 TERRAIN CATEGORY The wind speed at a structure is infl uenced by the terrain it fl ows over as it approaches the structure. The terrain category
SUPERDEK - Stratco
www.stratco.com.auRoofing calculations are based on Cpe=-0.9 and Cpi=0.2, walling is based on Cpe=-0.65 and Cpi=0.2. A local pressure factor, Kl=2.0 has been used for all roofing spans for both strength and serviceability limit states. Roof spans take into consideration loads incidental to maintenance. All pressures have been determined assuming wind
Related documents
Gutter System Installation Standards Product Specification
d3qhul1lf5l450.cloudfront.net3” x 4” Aluminum Downpipe .019 Gauge Aluminum . Spectra Metal Sales, Inc. is a member of the National Coil Coating Association and uses the NCCA’s standards as guidelines for physical testing. • The Aluminum used is alloy 3105-H15 or 3105-H25 which meets the
Rainwater Systems - Marley
www.marleyplumbinganddrainage.comsquare downpipe. With square downpipe With circular downpipe Socket clip The socket clip fits neatly around the iconic Marley socket, keeping the clip firmly in place. The iconic Marley socket The origins of the iconic double ‘bump’ on our rainwater pipe socket stem from the fact that Marley was the first company in the UK to manufacture
Split System Air Conditioning - Victorian Building Authority
www.vba.vic.gov.audownpipe that the condensate drain does not cause an obstruction in the downpipe. Technical Solution Sheet 7.08 Updated June 2014 www.vba.vic.gov.au Page 3 of 6 Figures 3, 4 & 5 Requirements: 1. There is a form of disconnection to prevent leakage into the building from the indoor unit if there is blockage in the downpipe ...
System, Split, Conditioning, Downpipes, Split system air conditioning
Understanding the NCC – Gutter and downpipe provisions for ...
abcb.gov.auGutter and downpipe provisions for housing The Performance Requirements of the National Construction Code (NCC) can be met by either using a Performance Solution, a Deemed-to-Satisfy (DTS) Solution, or a combination of both. The following is a general representation of the DTS Acceptable
Planning and Installing Underground Drainage Systems by …
www.diydoctor.org.ukdownpipe and a soakaway drain. 68mm downpipes are simply connected to the top inlet. The outlet is 110mm pipe spigot sized. The cover can be lifted to allow the removal of debris such as leaves. The gully can be rodded should the drain become blocked. The 68mm Rainwater Reducer (432-009) is used to connect the 68mm circular