Pocket Anesthesia
to terminology. It is the responsibility of the user to ensure all information contained herein is current and accurate by using published references. This card is a collaborative effort by representatives of multiple academic medical centers. Maintenance Fluids - “4-2-1” Rule 4 mL/kg/hr: each kg up to 10 kg 2 mL/kg/hr: each additional kg ...
Download Pocket Anesthesia
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Respiratory Therapy Pocket Reference P
anesthesia.ucsf.edua.k.a. “AC” Assist Control; AC-VC, ~CMV (controlled mandatory ventilation = all modes with RR and fixed Ti) Settings RR, Vt, PEEP, FiO2, Flow Trigger, Flow pattern, I:E (either directly or via peak flow, Ti settings) Flow Square wave/constant vs Decreasing Ramp (potentially more physiologic) I:E Determined by set RR, Vt, & Flow Pattern (i.e. for any set
Reference, Flows, Therapy, Pocket, Respiratory, Peak, Peak flow, Respiratory therapy pocket reference
Cardiac Anesthesiology Made Ridiculously Simple
anesthesia.ucsf.edubed you will have to take the angle into account and few can do trigonometry in your head. I will be glad to test you on this point. Then take the 5 mHz probe and map out the path of the carotid and the IJ. The IJ is bigger and collapses under pressure, the carotid is round and doesn't collapse under reasonable pressure.
UCSF Guideline for the Perioperative Management of ...
anesthesia.ucsf.edu- Use continuous regional anesthesia techniques if possible (epidural and peripheral nerve catheters) - Use IV ketamine, lidocaine intra-operatively if not contraindicated - Discuss pros and cons of delaying surgery for patient optimization if patient is still taking a …
Pulse Pressure Variation - UCSF Dept of Anesthesia
anesthesia.ucsf.eduPulse Pressure Variation (PPV) for Goal-Directed Fluid Therapy !!"= !! %&’−!! %)*!! %+&* × 100 PPV is a dynamic marker of a patient’s position on the Frank-Starling curve – predictor of fluid responsiveness • Requires arterial BP monitoring • Can be displayed on most OR and ICU monitors • With positive-pressure inspiration ...
MAINTENANCE FLUID REQUIREMENTS RESUSCITATION …
anesthesia.ucsf.eduSodium bicarb 1 mEq/kg/dose IV D50 1 mL/kg + insulin 0.2 U/kg IV Albuterol 5-20 mg via nebulizer Furosemide 1 mg/kg IV PRN Kayexalate 1-2 g/kg PO/PR ENDOCARDITIS PROPHYLAXIS GUIDELINES AHA 2007 At risk conditions 1. Presence of prosthetic valve or prosthetic material used for cardiac valve repair 2. A history of endocarditis 3.
Obstetric Anesthesia
anesthesia.ucsf.eduObstetric Anesthesia Pocket Guide Card designby numerous collaborators.Please send comments to: M. Lipnick (ZSFG), J. Markley (ZSFG), K. Harter (ZSFG) or A. Kintu(MakCHS) Makerere University Phone # ZSFGOB anes 1stcall (resident) 30010 ZSFG OB anes 2ndcall (attndg) 30011 (day),30001 (nite/wknd/holid) ZSFGL&D front desk (628-20)68725
Lidocaine Infusion for Analgesia
anesthesia.ucsf.eduLidocaine Infusion for Analgesia MOA Dosing Pharmacology References Perioperative Use Local Anesthetic Systemic Toxicity (LAST) 1. Attenuation of proinflammatory effects:
UCSF Perioperative Antibiotic Guidelines Recommended …
anesthesia.ucsf.eduUCSF Perioperative Antibiotic Guidelines Recommended Doses and Redosing Intervals Antimicrobial. ... American Society of Health-System Pharamcists & Infectious Diseases Society of America "Clinical Practice Guidelines for Antimicrobial Prophylaxis in Surgery," 2013. *Service specific recommendations adapted from above Guidelines
Stroke Volume Variation “Can We Use Fluid to Improve ...
anesthesia.ucsf.eduan available parameter with the FloTrac sensor and the Vigileo monitor. Study Patients Volume Tidal Volume Parameters R2 Def. of Sensitivity Specificity ml/Kg Tested (Artery) Responder Michard2 Berkenstadt, et al.1 Reuter, et al.3 Rx only. See instructions for …
Related documents
SN54/74LS283 4-BIT BINARY FULL ADDER WITH FAST CARRY
mil.ufl.eduIH Input HIGH Current Any A or B 40 µA = MAX, V = 2.7 V Input HIGH Current C0 0.1 mA VCC = MAX VIN =70V Any A or B 0.2 mA = MAX, V = 7.0 V IIL Input LOW Current C0 –0.4 mA Input LOW Current VCC = MAX VIN =04V Any A or B –0.8 mA = MAX, V = 0.4 V IOS Short Circuit Current (Note 1) –20 –100 mA VCC = MAX ICC Power Supply Current
MCP23017/MCP23S17 Data Sheet - Microchip Technology
ww1.microchip.comMCP23017/MCP23S17 DS20001952C-page 6 2005-2016 Microchip Technology Inc. FIGURE 1-3: I2C BUS START/STOP BITS TIMING FIGURE 1-4: I2C BUS DATA TIMING TABLE 1-3: I2C BUS DATA REQUIREMENTS I2C Interface AC Characteristics: Unless otherwise noted, 1.8V VDD 5.5V at -40 C TA +125 C, RPU (SCL, SDA) = 1 k , CL (SCL, SDA) = 135 pF Param. No.
NX5P3290 - USB PD and Type-C current-limited power switch
www.nxp.comILIM A3 current limiter. connect a resistor to GND to adjust the current limit level FLT A4 fault condition indicator (open-drain output) EN B4 enable input (active HIGH with internal 1M pull down resister) GND B3, C3, D3 ground (0V) FO C4 Fast turn on. Pull this pin HIGH to enable fast turn-on feature. 1M pull down resister integrated.
HTR-6230 - Yamaha
usa.yamaha.comwith a polarized alternating current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a safety feature. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact
16-channel analog multiplexer/demultiplexer
assets.nexperia.comand a digital enable input (E). When E is HIGH, the switches are turned off. Inputs include clamp diodes. This enables the use of current limiting resistors to interface inputs to voltages in excess of VCC. 2. Features and benefits • Wide supply voltage range from 2.0 V to 10.0 V • Input levels S0, S1, S2, S3 and E inputs: • For 74HC4067 ...
SN74LVC2G07 Dual Buffer and Driver With Open-Drain …
www.ti.comactive-low wired-OR or active-high wired-AND functions. The maximum sink current is 32 mA. NanoFree package technology is a major breakthrough in IC packaging concepts, using the die as the package. This device is fully specified for partial-power-down applications using Ioff. The Ioff circuitry disables the outputs, preventing damaging current ...
Octal buffer/line driver; 3-state
assets.nexperia.coma high-impedance OFF-state. Inputs include clamp diodes that enable the use of current limiting resistors to interface inputs to voltages in excess of VCC. 2. Features and benefits • Wide supply voltage range from 2.0 to 6.0 V • CMOS low power dissipation • High noise immunity • Latch-up performance exceeds 100 mA per JESD 78 Class II ...
LTC4415 - Dual 4A Ideal Diodes with Adjustable Current Limit
www.analog.comCurrent Limit VCLIM CLIM Clamp Voltage In Current Limit 0.5 V ILIM(ADJ) Current Limit Adjustability l 0.5 4 A Accuracy of Adjustable Current Limit Threshold VOUTx = VINx – 0.5V, Current Limit = 4A VOUTx = VINx – 0.5V, Current Limit = 2A l l ±8 ±15 % % ILIM(INT) Internal Current Limit RCLIMx = 0Ω, VOUTx = 0V l 4 6 9 A
NCV8450 - Self-Protected High Side Driver with Temperature ...
www.onsemi.comOutput Current Limit ILIM TJ = −40°C, VD = 13.5 V, tm = 100 s (Note 6) TJ = 25 °C, VD = 13.5 V, tm = 100 s TJ = 150 °C , VD = 13.5 V, tm = 100 s (Note 6) 0.5 0.8 1.5 A Output Clamp Voltage (Inductive Load Switch Off) At VOUT = VD − VCLAMP VCLAMP IOUT = 4 mA 45 52 V Overvoltage Protection VIN_CL ICLAMP = 4 mA 50 54 V 6. Not subjected to ...