Product Data - Carrier
REFRIGERANT Puronr (R---410A) Control TXV (Puron Hard Shutoff) Charge lb (kg) 13.07 (5.93) 13.70 (6.21) 13.73 (6.23) 14.78 (6.70) Outdoor Htg Piston # 46 55 61 67 COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 3200 3200 4350 5000 Motor HP 1/12 1/12 1/4 1/4 Motor RPM 800 800 825 825 COND COIL COND COIL
Download Product Data - Carrier
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
Product Data - Carrier
www.shareddocs.comThe 58SB0A/58SB1A Comfort™ Series 4-way Multipoise Gas ... • Microprocessor based control center • Adjustable heating air temperature rise ... Heating Blower Control Solid State Time Operation Burners (Monoport) 2 2 3 3 3 3 4 Gas Connection Size 1/2in. NPT GAS CONTROLS
Product, Center, Data, Control, Product data, Comfort, Control center
EVERYTHING YOU NEED FOR TOTAL COMFORT
www.shareddocs.commatched with a furnace or fan coil for year-round comfort. 3. n ® The Infinity System by Carrier is our most advanced . system, connecting the best components for the ultimate . home comfort control. n. Air quality is greatly enhanced with the addition of an air cleaner, humidifier and a ventilator. n. Forced-air systems are usually built ...
Service Manual - Carrier
www.shareddocs.comfeatures the latest variable speed technology. The heart of the system is the Copeland variable speed compressor powered through the use of the Emerson variable speed drive (VSD) inverter control. By Combining an ECM outdoor fan, Emerson VSD, Copeland variable speed compressor and the Infinity Series
Drive, Compressor, Speed, Variable, Variable speed drive, Variable speed, Variable speed compressor
Variable Refrigerant Flow (VRF) Systems
www.shareddocs.comAll VRF systems provide energy savings by varying compressor speed and matching the output of the system as closely as possible to the load. In addition, VRF systems do not experience the same energy losses as systems that move conditioned air through ductwork. However, differences in design the available in
Heating and Cooling Products for Your Home
www.shareddocs.com01-WM-009-01 A Carrier Company. Created Date: 3/25/2021 3:16:36 PM ...
Product Data WeatherMaster Gas Heat/Electric Cooling ...
www.shareddocs.comWeatherMaster® units up to 12.5 tons are specifically designed to fit on Carri-er roof curbs that were installed back to 1989, which makes replacement easy and eliminates the need for curb adapt-ers or changing utility connections. Single-stage units deliver SEERs up to 15.6, EERs up to 13.0, and IEERs up to 13.0. Two-stage units deliver EERs
Product Data WeatherMaker Single Packaged Rooftop
www.shareddocs.com48/50FC WeatherMaker® units up to 6 tons are specifically designed to fit on Carrier roof curbs that were installed back to 1989, which makes replace-ment easy and eliminates the need for curb adapters or changing utility connections. Single-stage units deliver SEERs up to 14.0. IEERs up to 15.2. All models are
EVOLUTION SYSTEM - Home Page for Carrier air conditioning ...
www.shareddocs.comoutdoor unit to provide top cooling efficiency and years of reliable service. Uses Captures & Kills® technology to inactivate 99% of select airborne pathogens trapped by the filter, including coronavirus, bacteria and other pathogens.4 Alleviates dry air by adding moisture. Transfers heating and cooling energy to the incoming fresh air.
INFINITY SYSTEM HEAT PUMPS - Home Page for Carrier air ...
www.shareddocs.comCoil Air Purifier Humidifier Ventilator Allows precise temperature control and humidity control along with programmable features to further customized your comfort. The indoor section of your heat pump and should be properly matched to the outdoor unit for improved efficiency and long-term reliability. Matches to the proper outdoor unit
System, Pumps, Indoor, Heat, Outdoor, Improved, Infinity, Infinity system heat pumps
Compact Water Source Heat Pumps
www.shareddocs.com•Interior panels feature an acoustical fiberglass lining for quiet operation. ... among the highest ratings in the indus-try. High quality construction and ... •50-VA transformer (tapped to 230V for all 208V/230V units) •Factory labeled terminal strip ther-
Related documents
Refrigerant Changeover Guidelines R-22 to R-407C
www.altairpartnerslp.com9. REFRIGERANT CHARGING WITH “ZEOTROPES”. R-407C is a zeotropic mixture. It is important that during initial charging or “topping” off a system that the refrigerant be removed from the charging cylinder in the liquid phase. Many of the cylinders for the newer refrigerants use a dip tube so that in the upright
PROPERTY TABLES AND CHARTS (SI UNITS)
homepages.wmich.eduTable A–11 Saturated refrigerant-134a— Temperature table Table A–12 Saturated refrigerant-134a— Pressure table Table A–13 Superheated refrigerant-134a Figure A–14 P-h diagram for refrigerant-134a Figure A–15 Nelson–Obert generalized compressibility chart Table A–16 Properties of the atmosphere at high altitude
Cased and Uncased Heat Pump / Cooling Coils 1 1/2 - 5 Ton ...
www.trane.com* Reducer supplied with R-410A model [1] These indoor coils are A.R.I. certified with various split system air conditioners and heat pumps (A.R.I. Standard 210/240). Refer to the split system product data guides for performance data. 2/4CXCA018AC3CUA 2/4CXCA024AC3CUA 2/4CXCB025AC3CUA 2/4CXCB031AC3CUA 2/4CXCB036AC3CUA INDOOR COIL--Type …
Product and Serial Number Nomenclature
www.virginiaair.com2 Refrigerant/Meter 4 = R-410A TXV 2 = R-22 TXV 3 = Flex Coil (No expansion device) A TXV Indicator A = Valve size 1 B = Valve size 2 3 = Valve size 3 X = No valve N Options H = Horizontal Pan (Factory Installed) N = No Options 1 Generation A Series MA Type MA = Modular Air Handler MV = Modular Varable Speed 08 = 800 CFM 16 = 1600 CFM
Chapter 10: Refrigeration Cycles - Saylor Academy
resources.saylor.orgR L net in HP H net in == − − == − − ,, 14 21 23 21 Example 10-1 Refrigerant-134a is the working fluid in an ideal compression refrigeration cycle. The refrigerant leaves the evaporator at -20oC and has a condenser pressure of 0.9 MPa. The mass flow rate is 3 kg/min. Find COPR and COPR, Carnot for the same Tmax and Tmin, and the tons of ...
Product Data - Carrier
www.shareddocs.comREFRIGERANT Puron (R---410A) Control TXV (Puron Hard Shutoff) Charge lb (kg) 5.00 (2.27) 5.40 (2.45) 6.38 (2.89) 6.38 (2.89) 7.5 (3.40) 8.30 (3.76) 8.60 (3.90) Outdoor Htg Exp. Device EXV COND FAN Forward Swept Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 1600 2080 2500 2500 3800 4500 4500 Motor HP 1/5 1/5 1/3 1/3 1/3 1/3 1/3
Refrigerant Piping Handbook - icemeister.net
www.icemeister.netRefrigerant Piping Application Considerations • System design for MINIMUM pressure drop. Pressure loss results in: a. decrease in thermal capacity b. increase power requirements (see page 8) • Refrigerant being piped DOES NOT change state. • Lubricants are miscible with refrigerants. • minimize the accumulation of liquid
R134a Pressure Temperature Chart - A-Gas
www.agas.comR134a Pressure Temperature Chart 14 4.73 3.72 53.88 16 5.04 4.03 58.43 18 5.37 4.36 63.20 20 5.72 4.70 68.21 22 6.08 5.07 73.46 24 6.46 5.44 78.95 26 6.85 5.84 84.70
Chart, Pressure, Temperatures, R134a, R134a pressure temperature chart
TURYP1683AN40AN - Trane
www.trane.comR = Heat Recovery H = Heat Pump M = Single Phase HP Y = Inverter Compressor PERFORMANCE P = Standard Efficiency E = High Efficiency H = Hyper-Heat CAPACITY (BTUH) VOLTAGE 3 = 208/230V/3P/60Hz 4 = 460V/3P/60Hz 1 = 208/230V/1P/60Hz MODULE SIZE A = Single B = Double C = Triple GENERATION CODE N = 9th Generation REFRIGERANT 4 = …