QUALITY STANDARDS FOR STRUCTURAL WORKS

QUALITY STANDARDS FOR STRUCTURAL WORKS

Back to document page

for Concrete Uniformity 1) To conduct NDT using ultrasonic pulse velocity (UPV) to check the degree of uniformity of hardened concrete 2) 5 columns/walls per set and 2 readings per column/wall 3) Assessment is based on the difference between 2 UPV readings within a column/wall not exceeding 0.05 km/s 4) Method as per SS 78 : Part B3 : 1992