Simpson Strong-Tie SET-XP High-Strength Epoxy Adhesive
Bond strength (moist cure) ASTM C882 2,916 psi at 2 days Water absorption ASTM D570 0.10% Compressive yield strength ASTM D695 14,110 psi Compressive modulus ASTM D695 612,970 psi Shore D Durometer ASTM D2240 84 Gel time ASTM C881 60 minutes Volatile Organic Compound (VOC) — 3 g/L
Download Simpson Strong-Tie SET-XP High-Strength Epoxy Adhesive
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Design No. U419 BXUV.U419 Fire Resistance …
www.buildsite.comBXUV.U419 Fire Resistance Ratings ANSI/UL 263 1/11 Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 Design/System/Construction/Assembly Usage …
Hilti - 2011 Anchor Fastening Technical Guide
www.buildsite.comNorth American Product Technical Guide Volume 2: Anchor Fastening Technical Guide A guide to specification and installation 2011 Edition
T-14 Tilt-Up Wall Braces - Product Data - …
www.buildsite.comBracing Information Bracing Information T-14 Tilt-Up Wall Braces To Order: Specify: (1) quantity, (2) Name, (3) model. Example: 200, T-14 Tilt-Up Wall Braces.
Where to Use Construction
www.buildsite.comConstruction SikaGroutÆ 328 High performance, precision, grout with extended working time Description SikaGrout 328 is a non-shrink, cementitious precision grout powered by ViscoCrete technol- ogy. This grout provides extended working time and exceptional physical performance at
Solar Reflectance Index (SRI) values for colored concrete
www.buildsite.comSETTING THE STANDARD FOR CONCRETE COLORS 3700 E. Olympic Blvd. Los Angeles, Calif 90023-3123 Tel 800-356-4848 Tel 323-269-7311 Fax 323-269-1053
Page 1/8 Safety Data Sheet acc. to OSHA HCS
www.buildsite.comPage 1/8 Safety Data Sheet acc. to OSHA HCS Printing date 05/24/2016 Reviewed on 05/24/2016 42.1.0 1 Identification · Product identifier · Trade name: Sure Hard™ Densifier J17 · Article number: 83-68082 · Application of the substance / the mixture · Details of the supplier of the safety data sheet
Owens Corning - Tru PROtection Preferred Limited Warranty
www.buildsite.comOWENS CORNING TRU PROTECTION PREFERREDTM LIMITED WARRANTY Thank you for your recent purchase of Owens Corning ... purchaser of a complete roofing system from Owens Corning to be installed on a single-family dwelling with a roof that is no larger than 150 roofing squares. (A roofing square is equal to 100 square
Guide to Curing - buildsite.com
www.buildsite.comGuide to Curing 4226 Kansas Ave, Kansas City, Kansas 66106 | 877-266-7732 | www.DaytonSuperior.com 1/18/2016 Page 1 of 2 The term “Curing” can be used to describe the process by which hydraulic-cement concrete matures ... Curing Concrete. The curing compound shall
Knauf EcoBatt® Insulation - Product Data
www.buildsite.comData Sheet BI-BT-DS 08-17 Thermal/Acoustical Insulation. ... makes Knauf Insulation product sizes and speciications easy to read. Knauf Insulation’s unitized packaging saves time at the jobsite and space in the warehouse. Master bag batt units ensure reduced handling costs with greater
Product, Sheet, Data, Data sheet, Product data, Insulation, Insulation products
Safety Data Sheet (SDS) - buildsite.com
www.buildsite.comSafety Data Sheet (SDS) Date Prepared/Revised: 8/7/2015 Version no.: 02 Supersedes: (10/29/2014) For proper disposal of used material, an assessment must be completed to determine the proper
Related documents
Chapter 9: Column Analysis and Design
academic.csuohio.edu= allowable compressive stress per code (psi or ksi) • This stress equation can be rewritten into a design form to determine the required short column size when the load and allowable material strength are known. A required = P actual /F a where A required = minimum cross-sectional area of the column Long Columns – Euler Buckling
Designing and Proportioning Normal Concrete Mixtures ...
www.ce.memphis.eduStrength The specified compressive strength, ˘, at 28 days is the strength that is expected to be equal to or exceeded by the average of any set of three consecutive strength tests. ACI 318 requires for ø to be at least 17.5 MPa (2500 psi). No individual test (average of two cylinders) can be more than 3.5 MPa (500 psi) below the specified ...
Wood: Strength and Stiffness - Forest Products Laboratory
www.fpl.fs.fed.usobtained from elastic theory. Strength properties in directions other than parallel (P) or perpendicular (Q) to the grain can be approximated using a Hankinson type formula: where q is the angle to the grain. For bending and tensile strength, N ranges from 1.5 to 2, and for compressive strength from 1.5 to 2.0. For the modulus wood.a
IS 516 (1959): Method of Tests for Strength of Concrete
www.iitk.ac.indetermination of compressive strength, flexural strength and modulus of elasticity of concrete. Sampling and analysis of concrete have been covered separately in IS: 1199-1959Methods of Sampling and Analysis of Concrete. 0.3 The Sectional …
Concrete, Strength, Compressive, Compressive strength, For strength of concrete
Guide to Evaluation of Strength Test Results of Concrete
dl.mycivil.irstrength) is the compressive strength of a single cylinder (ASTM C39/C39M); a single cylinder strength is part of, but individually does not constitute, a test result. normal distribution—a frequently occurring natural distribution that has predictable properties. The analysis of strength test results presented in this guide assumes that the
IS 3495-1 to 4 (1992): Methods of tests of burnt clay ...
www.iitk.ac.inCompressive strength in N/mm2 ( kgf,cm2) = Maximum load at failure in N(kgf) Average area of the bed faces in mm2 ( cm2 ) 4.1.4.1 The average of results shall be reported. 4.2 For Perforated Bricks 4.2.1 Apparatus See 4.1.1. 4.2.2 Preconditioning Immerse the specimen in water at room tempe- rature for 24 hours.
COMPRESSIVE STRENGTH OF CONCRETE
iricen.gov.inThe measured compressive strength of the cubes shall be calculated by divid ing the maximum load applied to the cubes during the test by the cross-sectional area, calculated from the mean dimensions of the section and shall be expressed to the nearest 0.5 N/mm2. In determining the compressive strength, do
Concrete, Strength, Compressive, Compressive strength, Compressive strength of concrete, The compressive strength