tensile ultimate that exceeds 2.0 times the corresponding allowable tension A. While conservative for basic tensile T strength, this also means that a nut might be subjected to a larger tensile force than would otherwise be the case. In conclusion, it is recommended that Method 1 be used in the case of a partially engaged nut and anchor rod.