Roofing calculations are based on Cpe=-0.9 and Cpi=0.2, walling is based on Cpe=-0.65 and Cpi=0.2. A local pressure factor, Kl=2.0 has been used for all roofing spans for both strength and serviceability limit states. Roof spans take into consideration loads incidental to maintenance. All pressures have been determined assuming wind
Download SUPERDEK - Stratco
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
STRATCO FRONTIER ASSEMBLY INSTRUCTIONS.
www.stratco.com.au7.0BARGECAPPING Only the front and two sides of the carport require the attachment of barge capping. The rear has the gutter attached. Fix the side barge capping first.
INSULATED ROOFING, - stratco.com.au
www.stratco.com.auCOOLDEK® ROOFING INSULATED PATIO ROOFING TABLE 3.0 - SINGLE SPAN WIND CAPACITIES (kPa) SPAN (mm) P r o fi l ePanel Thickness Limit State 1800 …
Purlins & Girts - stratco.com.au
www.stratco.com.au1 The Stratco Capacity Tables have been calculated in accordance with limit state design principles and comply with the Australian/ New Zealand Standard AS/NZS 4600:2005 Cold-formed steel
INSULATED ROOFING,
www.stratco.com.auFor Cooldek roofi ng in attached or freestanding domestic gable patio application, sheet spans shall not exceed those given for one or no open sides. Alternatively, Table 3.0 indicating wind capacities may be used to determine allowable single spans for any application. Spans specifi ed for units with three sides open are suitable for
Cooldek Outback Flat Attached Installation Guide
www.stratco.com.auIt is the builder’s responsibility to ensure any existing structure that an Outback is being attached to is adequately reinforced to accommodate the additional loads imposed by the verandah, patio or carport. Read these instructions thoroughly before starting your project and refer to them constantly during each stage of construction.
OVERFLOW SOLUTIONS - Stratco
www.stratco.com.ausystem (who may be the architect, builder, hydraulic engineer, home owner, roofing or guttering contractor) to design a ... The following overflow solutions provide a measure for continuous overflow for the full length in which the solution is applied.
POST & RAIL FENCING 1300 155 155 SCAN THIS QR CODE TO …
www.stratco.com.auStratco Post & Rail fencing is a traditional and cost e˜ ective form of fencing. Its simple design makes it the ideal choice for a ... Fence capping is placed over the top edge of the fence sheet with the long side of the capping facing the post and rail side of the fence. The capping is slightly tapered to allow for overlapping.
Roller Door - Stratco
www.stratco.com.audoor to be installed and if the headroom is a restricted space. • If the roller door is installed with a headroom greater then those listed in the Headroom Measurements table, the resulting daylight opening will be reduced. • If the roller door is installed significantly below the top of the
Fencing Frameless Glass Catalogue - Sheds | Fencing | Roofing
www.stratco.com.au12mm Fully Frameless Glass flat polished edges 5mm radius corners 01 Stratco Order Code G.O. Order Code Width Sqm Corner Radius Glass Weight KGS ... base plate - 10mm thick 95mm 73mm inner hole diameter 12mm 95mm 73mm 26 11 100 187 127 95 NOT TO SCALE 60 NOT TO SCALE 21 239 111 52 128 52 • Stainless Steel 2205
WIND CLASSIFICATION, - Stratco
www.stratco.com.auN1 (Non-Cyclonic) N/A W28 N2 (Non-Cyclonic) N/A W33 N3 (Non-Cyclonic) C1 (Cyclonic) W41 N4 (Non-Cyclonic) C2 (Cyclonic) W50 N5 (Non-Cyclonic) C3 (Cyclonic) W60 N6 (Non-Cyclonic) C4 (Cyclonic) W70 TERRAIN CATEGORY The wind speed at a structure is infl uenced by the terrain it fl ows over as it approaches the structure. The terrain category
Related documents
The Strom E-Boiler INSTALLATION GUIDE
stromltd.com- The local building regulations - UK building regulations BS EN 12828 Heating systems in buildings: Design for water-based heating systems. BS EN 12831 Heating systems in buildings: Method for calculation of the design heat load BS EN 14336 Heating systems in buildings: Installation and commissioning of water-based heating systems BS7671
Lintel Product Selector - Catnic
catnic.comTo limit the risk of surface condensation or mould growth the temperature factor for a detail used in the external wall of a dwelling must be greater than 0.75. Used in the above details, the Catnic CG, CH, CX, TS, TH & TX Lintels all have temperatures factors greater than 0.75. All calculations have been carried out following the conventions
Product, Limits, Calculation, Selector, Lletin, Lintel product selector
OBC SB-10 Energy Efficiency Requirements Prescriptive ...
oaa.on.caBased on location and use, select the values for building components from tables in SB-10 or the chosen standard. Envelope calculations are limited to area and percentage. Tradeoffs require balancing area weighted averages7. For Part 3 buildings: 8Determine if your building is exempt from the requirements of SB-10 . Existing buildings, open air
FLORIDA BUILDING CODE, Energy Conservation
www.floridabuilding.orgbuilding complies as a whole by means of an energy simulation analysis tool where the performance of the building as designed is compared to its performance when calculated with Standard Reference Design features (effectively, the building must come in under an energy budget). There are few minimum code requirements in a performance-based code.