加熱保温バンドル・チューブ ... - swagelok.com
ミリ・サイズ ① ジャケットの最高表面温度:60°C(プロセス温度204°C、周囲温度26°C、風速 16 km/h の場合) していますウレタン製ジャケットの最高表面温度:121°C
Download 加熱保温バンドル・チューブ ... - swagelok.com
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Pre-Insulated Tubing Bundles - Swagelok
www.swagelok.comPre-Insulated Tubing Bundles 3 TUBING (227) BUNDLES The bundle is designed so that the jacket surface temperature will not exceed 140°F (60°C) with a process temperature of 400°F (204°C), an ambient
Bundle, Tubing, Insulated, Pre insulated tubing bundles, Swagelok
Leak Detectors, Lubricants, and Sealants (MS-01 …
www.swagelok.comLeak Detectors, Lubricants, and Sealants 3 LEAK DETECTORS LUBRICANTS SEALANTS Features Composition: Cures to a bond that resists vibration or shock Lubricates threads, preventing costly thread damage due to galling and
Lubricants, Sealant, Lake, Detectors, Leak detector, And sealants
Grab Sampling Systems - Swagelok
www.swagelok.com• Provides a simple, effective way to safely collect samples • Keeps samples in their representative state for analysis • Can be adapted to meet system requirements
An Installer’s Pocket Guide for Swagelok Tube Fittings (MS ...
www.swagelok.comSee Swagelok tube fitting installation and reassembly, page 10 and 12 . Plugs While holding fitting body steady, tighten the plug one-quarter turn from the finger-tight position . For 1/16, 1/8, and 3/16 in.; 2, 3, and 4 mm tube fittings, tighten the plug one-eighth turn.
Hand Tube Bender Manual (MS-13-43;rev 5;en-US ... - …
www.swagelok.comHand Tube Bender Manual www.swagelok.com. 2. 3 Contents ... Read this manual before using the hand tube bender . Tubing Data The Swagelok hand tube bender bends 1/8, 1/4, 5/16, 3/8, and 1/2 in ., and 3, 6, 8, 10, and 12 ... when bending softer tubing such as copper or aluminum .
Manual, Using, Tubes, Hands, Tubing, Bending, Swagelok, Benders, Hand tube bender manual, Hand tube bender manual www
Ball Valves, General Purpose and Special Application 60 ...
www.swagelok.com• Swagelok ball valves are designed to be operated in ... (2-way) design. The one-piece center body uses no welding and allows 180° actuation. The switching design allows the user to: divert flow from a common inlet to one of two outlets ... Every 60 series ball valve is …
One-Piece Instrumentation Ball Valves - Swagelok
www.swagelok.comOne-piece ball stem ensures alignment of stem and orifice. 40T and 40E Series for Low-Temperature Service SW ... One-Piece Instrumentation Ball Valves—40G Series and 40 Series 5 40G / 40 SERIES BALL ... The 40G series valve is designed for thermal cycling …
Valves, Instrumentation, Ball, Pieces, Swagelok, Piece ball, One piece instrumentation ball valves
Pressure Regulators K Series - Swagelok
www.swagelok.comPressure Regulators K Series Pressure-reducing models Back-pressure models Gas cylinder changeover model Vaporizing models www.swagelok.com. 2 Pressure Regulators and Filters K SERIES REGULATORS ... High-Pressure (KPP Series), 16 High-Flow (KPF Series), 18 High-Pressure
High, Series, Pressure, Cylinder, Regulators, Swagelok, Pressure regulators k series, Pressure regulators k series pressure
Trunnion Ball Valves - Swagelok
www.swagelok.comTrunnion Ball Valves—83 Series and H83 Series 1 83 / H83 SERIES BALL Trunnion Ball Valves 83 Series and H83 Series Working pressures up to 10 000 psig (689 bar) 1/8 to 1/2 in. and 6 to 12 mm Swagelok® tube fitting or NPT end connections 316 stainless steel materials www.swagelok.com
VCO O-Ring Face Seal Fittings - Swagelok
www.swagelok.comVCO O-Ring Face Seal Fittings 1 FACE SEAL FITTINGS VCO ® O-Ring Face Seal Fittings 1/8 to 1 in. sizes 316 or 316L stainless steel Tube, NPT, SAE thread, and weld connections www.swagelok.com
Related documents
HF Alkylation Spec - cemsi.on.ca
www.cemsi.on.caAnalyzeIT Process FT-IR Spectrometer HF Alkylation Process Acid Analyzer Configuration The HF Alkylation Process Acid Analyzer System consists of: Analyzer – Includes spectrometer, PC, monitor,
gyrolok® tube fittings - Hoke
www.hoke.comGyrolok® Tube Fittings 3 Interchangeability and Intermixability The Interchangeability Guarantee HOKE’s experience in manufacturing HOKE valves with Swagelok® ends enables us to ensure that the Gyrolok® fi tting body is
Medium- and High-Pressure Fittings, Tubing, …
www.ilc.ptMedium- and High-Pressure Fittings, Tubing, Valves, and Accessories 1049 MEDIUM- AND HIGH-PRESSURE Swagelok Medium-Pressure, Gaugeable Tube …
High, Pressure, Fitting, Valves, Tubing, Swagelok, High pressure fittings
Instrument Ball Valves - Intrade
www.istcgroup.comInstrument Ball Valves 40 Series On-off, switching, and crossover flow paths Working pressures up to 3000 psig (206 bar) Temperatures from 50 to 150°F (10 to 65°C)
MDM50 Portable Hygrometer
www.michell.comwww.michell.com Portable Instruments MDM50 Portable Hygrometer A compact and easy to use portable hygrometer with fast response, integrated sampling system
250E Gas Inlet Pressure/Flow Control Module
www.mksinst.comWWW. MKSINST. COM 250E PRESSuRE/FLOW COnTROL MODuLE The 250E is a self-contained PID control module designed to provide optimized control of the total pressure or flow of a gas (or gases) in a dynamic closed-loop system.
Control, Pressure, Flows, Module, Pressure flow control module
Steam Leakage Quantification and Cost - UE Systems
www.uesystems.com1 Swagelok Energy Swagelok Energy Steam Leakage Quantification and Cost Kelly Paffel Technical Manager Swagelok Energy 440-649-2738 Kelly.paffel@swagelok.com
Cost, Steam, Steam leakage quantification and cost, Leakage, Quantification, Swagelok