Example: bachelor of science

59TP6 PDS926TB PG96VTA - DCNE

59TP6B. Performance Two---Stage, Variable Speed 4---Way Multipoise 35---in. (889 mm) Tall Condensing Gas Furnace Product Data PERFORMANCE. S Variable--speed, constant--torque ECM blower motor, two--speed inducer motor, and two--stage gas valve. S Fully--insulated casing including blower section. S Aluminized--steel primary heat exchanger . S Stainless--steel condensing secondary heat exchanger . S Silicon Nitride Power heat Hot Surface Igniter. S Adjustable blower speed for heating, cooling, continuous fan, and dehumidification. S ComfortFan technology allows control of continuous fan speed from a compatible thermostat. INSTALLATION FLEXIBILITY. S 4--way multipoise design for upflow, downflow or horizontal installations, with unique vent elbow and optional through-- the--cabinet downflow venting capability. S Factory--configured ready for upflow applications. A11263. S Installation flexibility: sidewall or vertical vent.

The condensing heat exchanger, a stainless steel fin and tube design, is positioned in the furnace to extract additional heat. Stainless steel coupling box componentry between heat exchangers has exceptional corrosion resistance in both natural gas and propane applications. Optional Media Filter Cabinet— Enhanced indoor air quality in

Tags:

  Tubes, Heat, Exchanger, Heat exchangers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 59TP6 PDS926TB PG96VTA - DCNE

1 59TP6B. Performance Two---Stage, Variable Speed 4---Way Multipoise 35---in. (889 mm) Tall Condensing Gas Furnace Product Data PERFORMANCE. S Variable--speed, constant--torque ECM blower motor, two--speed inducer motor, and two--stage gas valve. S Fully--insulated casing including blower section. S Aluminized--steel primary heat exchanger . S Stainless--steel condensing secondary heat exchanger . S Silicon Nitride Power heat Hot Surface Igniter. S Adjustable blower speed for heating, cooling, continuous fan, and dehumidification. S ComfortFan technology allows control of continuous fan speed from a compatible thermostat. INSTALLATION FLEXIBILITY. S 4--way multipoise design for upflow, downflow or horizontal installations, with unique vent elbow and optional through-- the--cabinet downflow venting capability. S Factory--configured ready for upflow applications. A11263. S Installation flexibility: sidewall or vertical vent.

2 The 59TP6B Multipoise Variable--Speed Condensing Gas Furnace S Ideal height 35 (889 mm) cabinet: short enough for taller coils, features the two--stage Performancet System. The Comfort HeatR but still allows enough room for service. technology two--stage gas valve is at the heart of the comfort S Direct--vent/sealed combustion, single--pipe venting or provided by this furnace, along with the variable--speed ECM. ventilated combustion air. blower motor, and two--speed inducer motor. With an Annual Fuel Utilization Efficiency (AFUE) up to , the Performancet APPLICATIONS. Series two--stage gas furnace provides exceptional savings when S Propane convertible with gas conversion accessory kit. compared to standard gas furnaces. This Performance Gas Furnace S Convenient Air Purifier and Humidifier connections. also features 4--way multipoise installation flexibility, and is available in eight model sizes.

3 The 59TP6B can be vented for S 5 ton sizes (sizes 080----20, 100----20) allow 15 Amp breaker direct vent/two--pipe, ventilated combustion air, or single--pipe with accessory (order separately). applications. Low NOx units are designed for California installations and meet 40 ng/J NOx emissions. Can be installed in air quality CERTIFICATIONS. management districts with a 40 ng/J NOx emissions requirement. S All sizes meet ENERGY STARR Version criteria for gas All sizes are design certified in Canada. This furnace is not furnaces: 95%+ AFUE. designed for use in recreation vehicles, manufactured (mobile) S Cabinet air leakage less than at in. and cabinet air homes or outdoors. leakage less than at in. when tested in accordance with ASHRAE standard 193. S All sizes meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement TM.

4 1. RATED. CASING HEATING OUT- DIMENSIONS (IN.) PUT (BTUH) AFUE HEATING AIRFLOW. UP- COOLING. FLOW/ ENER- CFM CFM High heat - CFM @ FURNACE HORI- DOWN- GY (High (Low heat - ing ESP ESP. SIZE H D W High Low ZONTAL FLOW STARr Heating ing) (in. ) (in. ) MOTOR HP. 040V14-10 35 39,000 25,000 YES 800 560 1030 1/2. 040V17-12 35 39,000 25,000 YES 850 625 1105 1/2. 060V14-12 35 58,000 38,000 YES 1110 770 1115 1/2. 060V17-14 35 58,000 38,000 YES 1135 860 1475 3/4. 080V17-16 35 78,000 50,000 YES 1450 1130 1655 3/4. 080V21-20 35 78,000 51,000 YES 1555 1200 2005 1. 100V21-20 35 97,000 63,000 YES 1865 1435 2005 1. 120V24-22 35 117,000 76,000 YES 2120 1625 2190 1. {Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate. Minimum heat CFM when low--- heat rise adjustment switch (SW 1 ---3) and comfort/efficiency adjustment switch (SW1 ---4) on control center are OFF.)}

5 ESP --- External Static Pressure FEATURES AND BENEFITS. Comfort heat TechnologyR This feature with Adaptive ramping profiles, and quiet operation. It can provide cooling match Control is a proprietary function that promotes homeowner enhancements to increase the effective SEER of select Carrier air comfort through two stages of heating. This Carrier's furnace conditioner or heat pump systems. This motor does not report offers a patented algorithm that continually monitors and adjusts back RPM and static pressure to the furnace control. furnace operation by looking at both current and past conditions to Reliable heat exchanger Design The aluminized steel, clam determine the most effective stage of heating and the amount of shell primary heat exchanger was re--engineered to achieve greater time to run each stage, every cycle. efficiency out of a smaller size. The first two passes of the heat SmartEvapt Technology When paired with a compatible exchanger are based on the current 80% product, a design with thermostat, this dehumidification feature overrides the cooling more than ten years of field-proven performance and success.

6 Blower off-delay when there is a call for dehumidification. By These innovations, paired with the continuation of a crimped, deactivating the blower off-delay, SmartEvap technology prevents no-weld seam create an efficient, robust design for this essential condensate that remains on the coil after a dehumidification cycle component. from re-humidifying throughout the home. This results in reduced The condensing heat exchanger , a stainless steel fin and tube humidity and a more comfortable indoor environment for the design, is positioned in the furnace to extract additional heat . homeowner. Stainless steel coupling box componentry between heat exchangers Unlike competitive systems, SmartEvap technology only overrides has exceptional corrosion resistance in both natural gas and the cooling blower off delay when humidity control is needed. propane applications. Once humidity is back in control, SmartEvap re-enables the Optional Media Filter Cabinet Enhanced indoor air quality in energy-saving cooling blower off-delay.

7 The home is made easier with our media filter cabinet (available as an accessory). When installed as a part of the system, this cabinet ComfortFant Technology Sometimes the constant fan setting on a standard furnace system can actually reduce homeowner allows for easy and convenient addition of a Carrier high efficiency comfort by providing too much or too little air! ComfortFan air filter. technology improves comfort all year long by allowing the 4-Way Multipoise Design One model for all applications . homeowner to select the continuous fan speed of their choice using there is no need to stock special downflow or horizontal models a compatible thermostat. when one unit will do it all. Fan Technology Sometimes the constant fan setting on a Direct or Single-pipe Venting, or Optional Ventilated standard furnace system can actually reduce homeowner comfort Combustion Air This furnace can be installed as a 2-pipe by providing too much or too little air!

8 Fan On Plus technology (Direct Vent) furnace, in an optional ventilated combustion air improves comfort all year long by allowing the homeowner to application, or in single-pipe, non-direct vent applications. This select the continuous fan speed of their choice using a compatible provides added flexibility to meet diverse installation needs. thermostat. Sealed Combustion System This furnace brings in combustion HYBRID HEATR Dual Fuel system This system can provide air from outside the furnace, which results in especially quiet more control over your monthly energy bills by automatically operation. By sealing the entire combustion vestibule, the entire furnace can be made quieter, not just the burners. selecting the most economical method of heating. With HYBRID. HEATR Dual Fuel, our system automatically switches between the Insulated Casing Foil-faced insulation in heat exchanger gas furnace and the electric heat pump as outside temperatures section of the casing minimizes heat loss.

9 The acoustical insulation change to maintain greater efficiency and comfort than with any in the blower compartment reduces air and motor noise for quiet traditional single-source heating system. The heat pump also operation. delivers high-efficiency cooling in the summer. Monoport Burners The burners are specially designed and finely tuned for smooth, quiet combustion and economical Power Heatt Igniter Carrier's unique SiN igniter is not only operation. physically robust but it is also electrically robust. It is capable of Bottom Closure Factory--installed for side return; easily running at line voltage and does not require complex voltage removable for bottom return. The multi-use bottom closure can regulators as do other brands. This unique feature further enhances also serve for roll-out protection in horizontal applications, and act the gas furnace reliability and continues Carrier's tradition of as the bottom closure for the optional return air base accessory.

10 Technology leadership and innovation in providing a reliable and Certifications This furnace is CSA (AGA and CGA) design durable product. certified for use with natural and propane gases. The furnace is ECM Motors Our variable--speed, constant torque ECM factory--shipped for use with natural gas. A CSA listed gas (Electronically Commutated Motor) optimizes comfort levels in the conversion kit is required to convert furnace for use with propane home year round; features such as passive/active dehumidification, gas. The efficiency is AHRI efficiency rating certified. 2. MODEL NUMBER NOMENCLATURE. A190041. For California Residents: For installation in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: FURNACE COMPONENTS.