Example: bachelor of science

KEZ New Generation D Condensing Units

25/11/21 KEZC ondensing UnitsIndoor/Outdoor Air-Cooled Scroll Condensing Units3/4 to 17 HP - High and Low Temperature RefrigerationIndoor UnitOutdoor UnitCONTENTS , Options and Pre-Selected Option Fan Motor Technology .. Floating Head Pressure Control Capacity Walk-In Energy Factor (AWEF) Diagrams - Models with ..Product Support - 3456 - 1819 - 2223 - 2425 - 293031 - 3435 - 36 BACKSee Page 4 for detailsSee Page 5 for detailsBulletin K40-KEZD-PDS-8 Part # 1108861 PRODUCT DATA & SPECIFICATIONS PRODUCT SUPPORTweb: : 1-844-893-3222 x521scan:New Generation "D"Application RangeH = High and Med Temp L = Low Temp Refrigerant*8 = R407A, R407C, R448A, R449A, R404A, R507 EnclosureH = OutdoorI = Indoor Compressor ManufacturerA = CopelandNominal HP007 - 170 = 3/4 - 17 HP Model Series KEZ = Excel Scroll Air Cooled Condensing Unit LineIndoor Unit.

• Sealed liquid line filter drier & sight-glass •alve - liquid line (shipped loose) Ball v • Insulated suction lines • Leg kits • Discharge air hood • Sub cooling circuit on 5 - 17 HP models • Liquid line solenoid valve (with standard olt coil) - shipped loose230 v • …

Tags:

  Liquid, Line, Filter, Riders, Liquid line, Liquid line filter drier

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of KEZ New Generation D Condensing Units

1 25/11/21 KEZC ondensing UnitsIndoor/Outdoor Air-Cooled Scroll Condensing Units3/4 to 17 HP - High and Low Temperature RefrigerationIndoor UnitOutdoor UnitCONTENTS , Options and Pre-Selected Option Fan Motor Technology .. Floating Head Pressure Control Capacity Walk-In Energy Factor (AWEF) Diagrams - Models with ..Product Support - 3456 - 1819 - 2223 - 2425 - 293031 - 3435 - 36 BACKSee Page 4 for detailsSee Page 5 for detailsBulletin K40-KEZD-PDS-8 Part # 1108861 PRODUCT DATA & SPECIFICATIONS PRODUCT SUPPORTweb: : 1-844-893-3222 x521scan:New Generation "D"Application RangeH = High and Med Temp L = Low Temp Refrigerant*8 = R407A, R407C, R448A, R449A, R404A, R507 EnclosureH = OutdoorI = Indoor Compressor ManufacturerA = CopelandNominal HP007 - 170 = 3/4 - 17 HP Model Series KEZ = Excel Scroll Air Cooled Condensing Unit LineIndoor Unit.

2 Compatible with Low GWP Refrigerants Weatherproof electrical control box with compressor contactor and fused control circuit Copeland scroll compressor High efficiency enhanced tube and fin condenser design SmartSpeed EC Fan Motor Technology standard on models using chassis 1 (see page 35) Energy efficient PSC condenser fan motor on models using chassis 2 thru 6 (see page 35) Receiver with fusible plug and liquid shut off valve Suction service valve Pre-formed copper tubing liquid injection (low temp. models) Unit leak tested and shipped with helium holding charge Fixed high pressure switch and adjustable low pressure control Receiver inlet valve on 2-fan Units models only Discharge thermostat on applicable models only Painted cabinet Time delay relay for compressorOutdoor Unit: All Standard Features of Indoor Unit, Plus.

3 Painted weather-resistant housing with removable hood Flooded head pressure control (adjustable) Crankcase heater F an cycling control with flex hose (2 fan Units ) Suction accumulator with and without boil-out coil Discharge line check valve Oil separator with and without oil return filter and solenoid valve Receiver inlet ball valve Heated and Insulated receiver Over-sized receiver Sealed liquid line filter drier & sight-glass Ball valve - liquid line (shipped loose) Insulated suction lines Leg kits Discharge air hood Sub cooling circuit on 5 - 17 HP models liquid line solenoid valve (with standard 230 volt coil) - shipped loose Variable speed EC motors as head pressure control (see Bulletin K40-HPC-AG or for details) QuickVac Evacuation and Refrigerant Recovery Valves Dual pressure control with flex hoses Compressor circuit breaker Current sensing relay - for use with oil safety control (where applicable) Defrost heater contactor c/w fuse block Evaporator fan contactor c/w fuse block Disconnect switch Disconnect fusing Pump down toggle switch Lock out control circuit relay Mechanical time clock Electronic voltage / Phase monitor SmartSpeed Fan Motor Technology on models using chassis 2-6 (see page 4) Limitrol+ Floating Head Pressure Control System (see page 5 or Bulletin K40-LIMITROL-AG or for details)

4 Design GenerationD = Latest Catalog Series Voltage*S2 = 208/230-1-60 S3 = 230-1-60 S6 = 200/220-1-50 S7 = 200-1-50 T3 = 208/230-3-60 T4 = 460-3-60T5 = 575-3-60 T7 = 200/220-3-50T9 = 380/400-3-50* subject to compressor availability Pre-Selected Factory Mounted Option PackagesSee detail on next page KEZ A 075 H 8 - H T4 D - AKEZ - SCROLL Condensing UNITSNOMENCLATURESTANDARD FEATURESAVAILABLE OPTIONSK30-KEZD-PDI-825/11/21- 2 -Pre-Selected Factory Mounted Option PackagesSee detail on next pageFLGAALMSSCNCTNKYVAWVINILOHWIMIPANYME VTMANJCTRIMDDELAARMOTXOKKSNEIANMCOAZUTWY MNSDMDMTIDNVCAORWABCABSKMBONQCNBNSPENLNL AKYTNTNUHINHHigh / Moderate AmbientsModerate / Low AmbientsFor further details, visit our website and see Application Bulletin KAB-0101-02-1: "About Heated And Insulated Receivers"or contact your local sales : Package BBetter:Package NBest:Package PGood: Package DBetter:Package JBest:Package QFor High / Moderate Ambients:For Moderate / Low Ambients:For High / Moderate AmbientsFor Moderate / Low AmbientsPackage B: + liquid line filter Drier1 & Sight GlassPackage D: + liquid line filter Drier1 & Sight Glass + Heated and Insulated ReceiverPackage N: + liquid line filter Drier1 & Sight Glass + Suction Accumulator w/o Heat Exchanger Package J: + liquid line filter Drier1 & Sight Glass + Suction Accumulator w/o Heat Exchanger + Heated and Insulated ReceiverPackage P: + liquid line filter Drier1 & Sight Glass + Suction Accumulator w/o Heat Exchanger + Suction Filter2 + Non-Fused DisconnectPackage Q.

5 + liquid line filter Drier1 & Sight Glass + Suction Accumulator w/o Heat Exchanger + Suction Filter2 + Non-Fused Disconnect + Heated and Insulated ReceiverGOODBESTBETTER1 liquid line filter Drier: Sealed on ALL One Fan Model Units , Replaceable on ALL Two Fan Model Suction filter : Sealed on ALL One Fan Model Units , Replaceable on ALL Two Fan Model information on Evaporator Defrost Kits and Fuse Packages, visit KEZ - SCROLL Condensing UNITSPRE-SELECTED FACTORY MOUNTED OPTION PACKAGESRECOMMENDATIONS FOR SELECTING FACTORY MOUNTED OPTION PACKAGESK30-KEZD-PDI-825/11/21- 3 -K30-KEZD-PDI-825/11/21- 4 -DESIGN FEATURES Standard on models using chassis 1 (optional on chassis 2 thru 6) No special controls required. No worries about wind or cold climates. Ambients above 55 F - EC motor operates at full speed, crankcase heater and heated + insulated receiver disabled from control circuit Ambients below 55 F - EC motor operates at low speed, crankcase heater and heated + insulated receiver enabled from control circuit INSTALLATION NOTES4 5 6 7 8 9 10 11 12 -40 -20 0 20 40 60 80 100 120 EER (Btu/h/W) AMBIENT ( F) Condensing Unit EER - Standard vs.

6 KeepRite SmartSpeed Standard Unit KeepRite SmartSpeed 15 %* * BIN ANALYSIS SHOWS AN AVERAGE OF 10% SAVINGS OVER THE RANGE OF THE YEAR Condensing Unit EER - Standard Unit vs. SmartSpeedStandard UnitSmartSpeedCondensing Unit with SmartSpeed Power Consumption Per MotorChassis Size (see pages 31-35)Ambients above 55 Full and Receiver Heaters below 55 Low and Receiver Heaters W19 W2168 W37 W3,4362 W76 W5630 W152 WRefer to Pages 41-42 For Wiring DetailsUS Patent No. 9,297,567 AVAILABLE OPTIONSKEZ - SCROLL Condensing UNITSK30-KEZD-PDI-825/11/21- 5 -What is Limitrol+? Limitrol+ combines various technologies into a responsive system that floats head pressure, saving energy and reduces environmental competitive systems, Limitrol+ combines variable speed EC motor technology, condenser portioning and vari-ous systems modifications to provide the ultimate in performance and control.

7 As a result, Limitrol+ functions in much colder ambients where previous systems have proven does it do? Conventional head pressure control systems maintain a constant head pressure regardless of ambient temperatures. Limitrol+ intelligently responds to ambient conditions to float head pressure without sacrificing system performance at lower temperatures. What are its applications? Condensing Units over 5 HP Ideally suited and most effective in applications with fluctuating ambients Perfect for installations where reduced refrigerant charges are desired or much can Limitrol+ save you? Reduces compressor energy consumption and run time EC motor technology further saves energy and reduces electrical requirements Lowered environmental impact through reduced refrigerant use Stable system performance in lower ambientsMODELP hiladelphia, PANew York, NYBoston, MACharlotte, NCAtlanta, GALos Angeles, CASt Louis, MOSt.

8 Paul, MNToronto, ON%$%$%$%$%$%$%$%$%$5 HP Cooler22616231,099251, HP Cooler211,008221,805231,7071884317954171 ,499191,053241,270251,00010 HP Cooler181,204182,131202,09515975141,0891 82,446161,227201,529211,22315 HP Cooler191,852203,300213,170161,567151,76 7193,570171,916222,337221,8346 HP Freezer24903251,621261,5482175320848231, 54822928261, HP Freezer21994211,783231,7261780016891181, 591191,012231,255241,004* The above is a BIN Hour Analysis. Weather data was used from ASHRAE Weather Data Viewer and electrical rates for each city are based on June 2013 data from EIA ( Energy Information Administration).** Above numbers do not include refrigerant savings, and further cost savings can be more information on Limitrol+ Floating Head Pressure Control System visit or see Bulletin K40-LIMITROL-AG ( )For more information on Head Pressure Control, please refer to our Head Pressure Control Application Guide Bulletin K40-HPC-AG ( )Standard UnitAVAILABLE OPTIONSKEZ - SCROLL Condensing UNITSK30-KEZD-PDI-825/11/21- 6 -KEZ - SCROLL Condensing UNITSSELECTION CAPACITY DATAM odelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C)

9 F R404A R507 High Temperaturetable continues on next page >>>N/A = Mean rating capacities do not apply to R404A/R507. table continues in next column K30-KEZD-PDI-825/11/21- 7 -KEZ - SCROLL Condensing UNITSSELECTION CAPACITY DATA R404A R507 High Temperature (cont d)ModelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F 8 -KEZ - SCROLL Condensing UNITSSELECTION CAPACITY DATAM odelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F continues on next page >>>Shaded Area Restriction: 20 F Max Superheat R407AR407 AHigh TemperatureModelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F continues in next column K30-KEZD-PDI-825/11/21- 9 -KEZ - SCROLL Condensing UNITSKEZ - SCROLL Condensing UNITSSELECTION CAPACITY DATAS haded Area Restriction: 20 F Max Superheat R407AR407 AHigh Temperature (cont d)ModelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F 10 -KEZ - SCROLL Condensing UNITSSELECTION CAPACITY DATA table continues on next page >>> R448AR448AR449AR449A High TemperatureShaded Area Restriction.

10 20 F Max Superheat ModelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F continues in next column K30-KEZD-PDI-825/11/21- 11 -KEZ - SCROLL Condensing UNITSKEZ - SCROLL Condensing UNITSSELECTION CAPACITY DATA R448AR448AR449AR449A High Temperature (cont d)Shaded Area Restriction: 20 F Max Superheat ModelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F 12 -KEZ - SCROLL Condensing UNITSSELECTION CAPACITY DATA R407C High TemperatureModelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F continues on next page >>>Shaded Area Restriction: 20 F Max Superheat ModelKEZAS aturated Suction Capacity BTU/h Ambient Temperature85 F ( C)90 F ( C)95 F (35 C)100 F ( C)105 F ( C)110 F ( C) F continues in next column K30-KEZD-PDI-825/11/21- 13 -KEZ - SCROLL Condensing UNITSKEZ - SCROLL Condensing UNITSSELECTION CAPACITY DATAS haded Area Restriction.