Example: stock market

2021 ICF Industry Form Specs Ties Performance Building ...

2021 ICF Industry Comparison ChartForm SpecsTiesPerformance DataBuilding ConsiderationsCode ApprovalsSupportCommentsDimensions (inches)Sq. ft. per cu. yd. (6 core) Wall Type (S)creen (W)affle (F)lat (P)anel (B)lock (H)inge(P)lastic (S)teel (E)PSSpacing (inches)Fire Rating (Hours)Sound AttenuationSidewall ThicknessHeight AdjustersInterlockingReversibleBrickledg eT-Blocks90 Corners45 CornerRadiusTaper TopEnd CapsOne-Sided FormingIn-Core Foam InsertsICC-ESCCMCW isconsinFloridaMiami-DadeCity of Los AngelesCAD Details BIM Library Engineering SupportTrainingInstallation HelpLength Height Core SizesManufacturerContact InfoManufacturing LocationsForm NameAmvic(877) 470-9991 , UT, AB, ON, INT LAmvic ICF R2248164-1253 FBP63+50+ effective, providing excellent performanceAmvic ICF R30 48166-853 FBP83+50+ Performance ICFB uildBlock Building Systems **(866) 222-2575 , AZ, CA, CO, FL, ID, IN, MA, MD, MO, SD, INT +YYYYYYYYYYYCode tested Termite Barrier (AWPA) & Firestop (ASTM E84)

Logix KD 48 16 4-12+ 54 F P, B P 8 4+ 56 2.75 Y Y Y Y Y Y Y Y Y Y Y ‡ ‡ Y Y Y Y Knockdown Line, Integrates with Logix Pro and Platinum Mikey Block Co. (520) 623-3023 www.mikeyblock.com AZ, NM, WI Mikey Block 48 12 N/A 91 S B E 12 55 Varies Y Y Y Y Y Cores are 5.5 inches 12” O.C Nudura Inc.** (866) 468-6299 www.nudura.com AB, GA, QC

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 2021 ICF Industry Form Specs Ties Performance Building ...

1 2021 ICF Industry Comparison ChartForm SpecsTiesPerformance DataBuilding ConsiderationsCode ApprovalsSupportCommentsDimensions (inches)Sq. ft. per cu. yd. (6 core) Wall Type (S)creen (W)affle (F)lat (P)anel (B)lock (H)inge(P)lastic (S)teel (E)PSSpacing (inches)Fire Rating (Hours)Sound AttenuationSidewall ThicknessHeight AdjustersInterlockingReversibleBrickledg eT-Blocks90 Corners45 CornerRadiusTaper TopEnd CapsOne-Sided FormingIn-Core Foam InsertsICC-ESCCMCW isconsinFloridaMiami-DadeCity of Los AngelesCAD Details BIM Library Engineering SupportTrainingInstallation HelpLength Height Core SizesManufacturerContact InfoManufacturing LocationsForm NameAmvic(877) 470-9991 , UT, AB, ON, INT LAmvic ICF R2248164-1253 FBP63+50+ effective, providing excellent performanceAmvic ICF R30 48166-853 FBP83+50+ Performance ICFB uildBlock Building Systems **(866) 222-2575 , AZ, CA, CO, FL, ID, IN, MA, MD, MO, SD, INT +YYYYYYYYYYYCode tested Termite Barrier (AWPA) & Firestop (ASTM E84)

2 All products connect and interchangeRadius block in 2 , 4 , 8 , 12 , 16 , & 20 arcBuildLock48164-12+ +YYYYYYG lobalBlock48164-685 SBE/P12N/A58 VariesMYYMYMMYYF urring strips optionalConform Global(800) 266-3676 , UTSmartblock + interlocking different thicknesses at cornersSmartblock 12 VWF40124-20+53 FPP4-6456+ Blocks **(877) 369-2562 , AL, AZ, CA, CO, FL, ID, MA, MO, NE, PA, SD, TX, UT, AB, MB, NB, QCFox YYYYYYYYYE xtended corners, full height furring strips, reversible interlockFox Blocks YYYYF ield assembled, forms a flat concrete wall. Integrates with the Fox Blocks series. Reveal one-sided wood removable. 4 -12 core available in 2 incrementsHercuTech(800) 289-3139 ,4125 SBE1230N/AYYYYYYYYD elivered as pre-engineered, panelized kitHobbs Building Systems(866) 904-9255 , AR, AZ, CO, GA, FL, ID, MN, SC, TN, TX, WA, QCHobbs Vertical ICF8, 16 Any6100W, FPP8,16250+VariesN/AN/AYYYYYYYYYYYA vailable in flat and contour wall options.

3 Engineered by projectIntegraSpec ICF(800) 382-9102 , CA, GA, MA, QC, INT LIntegraSpec +54 FPP83-4+ panel systemLiteForm Technologies(800) 551-3313 , ND, SD, VALiteForm ICF48164-1253FB, furring, compact corner optionLogix Insulated Concrete Forms**(888) 415-6449 , KS, MN, TN, BC, AB, MB, ON Logix Pro48164-12+54 FBP84+ YYYYYYYYYA vailable in some regions with termite resistant foamLogix Platinum48164-12+54 FBP84+ YYYYH igher insulation. Integrates with Logix ProLogix KD48164-12+54FP, BP84+ YYYYK nockdown Line, Integrates with Logix Pro and PlatinumMikey Block Co.(520) 623-3023 , NM, WIMikey Block4812N/A91 SBE1255 VariesYYYYYC ores are inches 12 Inc.**(866) 468-6299 , GA, QCNudura ICF Series96184-12+54FH, ,12 YYYYYYYYYYYY YYYYYYYYYW idest variety of block shapes, sizes and accessoriesNudura Plus Series96184-12+54FH, PP8455+ ,12 YYYMYYMYYYYY YYYYA chieve higher R-ValuesPlasti-Fab(888) 446-5377 , ONAdvantage , 853 FBP6, 83-450+ YYYYYC ontinuous concrete brickledgePolycrete(800) 570-4313 , QB, NOR, FRPolycrete Big Block9612,18, , factory pre-cut kitsVariable height split blocksFlex Building Systems**(888) 711-5625 , GA, AUS, ENGQuad-Lock (2")48124-28+56 FPP12455+ YYYYYYYYISO 9001 & 14001 certifiedStrong R-28 ICFFull height furring strips optionalQuad-Lock Ultra (3") 48124-28+56 FPP12455+ YYQuad-Lock Plus (4") 48124-28+56 FPP12455+ +MYYMYYMMMYY YYYR eddiForm(406) 587-4903 , FL, NY, PR ReddiForm48126, YYYYC ontinuous horizontal attachment/online estimatesReddi-Wall Inc.

4 (586) 752-9161 , ICF Corp(800) 424-9255 , MN, OHStandard flatwall maximizes efficiency, insulation and durabilityStronghold ICF(877) 433-1880 , OH, SD, ABStronghold ICF48164-1253FP,B, ,8,12 YYYYYYMYYY YYYYYYYYC ontinuous fastening flange, webs lock together, long corner blocksSuperform Products Ltd.**(877) 627-3555 YYYV irgin polypropylene tiesTF Forming Systems, Inc.(800) 360-4634 , MO, CO, GA, IA, NYThermoForm8 ANY4-24+56 FPP-S83-455+2-6N/AYYYYYYYYYYY PPYYYYV ertical panels give option of steel or plastic ties. XPS foam +56 FPP-S163-455+4-6N/AYYYYYYYYYYY PP Manufacturer has alternate certification to equal national N=Blank M=Made T&G= Tongue and Groove N/A= Not Applicable P=Pending** Member of the ICF Manufacturers Association Every effort has been made to ensure this information is complete and accurate at the time of printing. However, this chart is not adequate for the purposes of making construction decisions.

5 ICF Builder Magazine is not liable for any errors or omissions in the data. 2021 Any copying, redistribution or republication of this chart, or the content thereof, is strictly Comparison ChartDimensions (inches) Building ConsiderationsPerformanceCommentsWidthLe ngthBeam PocketSide InterlockShoringUtility ChasesRib MaterialFurring StripsFire Rating (hours)Sound AttenuationR-Value (7 panel)Deck SystemWebsitePhoneManufacturer LocationsAmdeck Pro by (877)-470-9991ON322410 None8-12 Y12, 14, 16 ga. steelPlasticP5019 Uses 10 lightweight steel C-channelsAmdeck Eco by (877)-470-9991ON24966, 8, 10T&G4 NWoodNonePPPUses 2 x 6 dimensional lumberBuildDeck by (866)-222-2575ID, MA, MO24248-12+None2 YNoneSteel +Simple shoring design Full engineering Clear span to 40 (800)-475-6720GA, BC24 Custom5-10+T&G6 Y22 ga. steel22 ga. moulded around perforated steelEPS Deck from Legalett (855) 333-2516 Quebec, Ontario, Alberta24/48 Custom4 -14 T&G 4 -6 to 67 Exposed steel stud ends to lock to concreteTransverse beams supplied for midspan concrete lock to steel studsSnap Track included for wire mesh support and rebar chairs for beamsEngineering available on requestFortruss by Beaver (888)-453-5961AB, NSteel/EPSS teel155+29 LiteDeck WRS/SRSby (877)-481-4714NE, OK, PA, SD, TX, VA, Puerto Rico, Panama24, 48964-12+T&G6 NSteel or woodSteel or with Top HatsEvery effort has been made to ensure this information is complete and accurate at the time of printing.

6 However, this chart is not adequate for the purposes of making construction decisions. ICF Builder Magazine is not liable for any errors or omissions in the data. Any copying, redistribution or republication of this chart, or the content thereof, is strictly N=Blank M=Made T&G= Tongue and Groove N/A= Not Applicable P=PendingForm SpecificationsPerfor-manceBuilding ConsiderationsCode ApprovalsCommentsWall TypeForm TypeDimensionsFire Rating (Hours)Tested R-ValueAnglesICC-ESCCMCM anufacturerContact InfoManufacturing LocationsBlock NameMaterial(S)creen, (W)affle, (F)lat(B)lock, (P)lank, (V)erticalLengthThicknessHeightColumn SizeWeightSF Filled per CY of 6 Spacing90 Corners45 CornersEnd CapsBlu 503-915-2752 ORBluBlocCement-EPS Systems (The Perfect Block) , 888-623-4223 AZPerfect BlockCement-EPS BlendSB486-10+124, 625-45118124+23-45 YMYYJ amaica, LA Approved Design, Take Off, Engineering AvailableEarth Friendly Building BlockCement-EPS BlendSB6010126409012421 MMME terna Building BlockCement-EPS , 480-500-8055AZ, MXRastraCement-EPS +20-35 YMMS ince 1972, Take Off and Engineering Fiber-CementSB24, +8- 28 YMMYE asily cut and adapted for many variations, proven since 1953 ShelterWorks, Fiber-CementSB241285-83081124+ since 1987, with design & engineering supportNuform Building (Vinyl)FV6to 30 4, 6, 8596-8222 YYYNo other finish neededOctaform (Vinyl)FV6to 30 4- 24+45-656222 YYYPPGray, white, or tan colorTypical EPS BlockEPS ComparisonFB48166<10556-8324 YYMYY Typical ICF BlockEvery effort has been made to ensure this information is complete and accurate at the time of printing.

7 However, this chart is not adequate for the purposes of making construction decisions. ICF Builder Magazine is not liable for any errors or omissions in the data. Any copying, redistribution or republication of this chart, or the content thereof, is strictly ICF ComparisonY=Yes N=Blank M=Made T&G= Tongue and Groove N/A= Not Applicable P=Pending


Related search queries