Transcription of General Purpose Relays - Farnell
1 General Purpose RelaysTypes K, R, N, and CCatalog8501CT0301R7/082008 Class 8501 CONTENTSD escription .. PageType R Miniature Plug-in Relays ..3 6 Type K Plug-in Relays ..7 8 Type KA Alternating Relays ..9 10 Type N Sockets and Accessories .. 11 13 Type C Power Relays ..15 2003-2008 Schneider ElectricAll Rights Reserved208/2008 Type R Miniature Plug-in RelayGeneral and Order Information308/2008 2003-2008 Schneider ElectricAll Rights ReservedThese miniature plug-in Relays have a 10 Ampere resistive rating (except for RS/RSD41), the same as the Type K plug-in Relays , but are much smaller.
2 The compact size of these Relays makes them ideal for downsizing equipment. SPDT through 4 PDT AC or DC Operated Horsepower rated hRS41 and RSD41 Relays have a B300 rating. S StockedFactory Order items require a minimum order quantity of 25 and have a lead time of 12 weeks. Voltage code must be specified to order this product. Refer to standard voltage codes listed in the Stocked Relay table to the left and insert as shown in How To Data .. page 5 Wiring Diagrams .. page 6 Dimensions .. page 6UL Contact RatingsTypeVoltageResistiveRatingGeneral UseRatingHorsepower Rating8501RS41 h120 VAC15101/3240 VAC12101/28501 RSD41 h28 VDC1515 8501RS42120 VAC10101/3240 VAC10101/28501 RSD4230 VDC1010 8501RS43120 VAC1010 250 VAC1010 8501 RSD4328 VDC1010 8501RS44120 VAC1010 250 VAC1010 8501 RSD4428 VDC1010 Stocked RelaysTypeAC Voltage 50/60 HzTypeDC Voltage61224120 24061224110 Voltage CodeV35V36V14V20V24 Voltage CodeV50 V51V53V60RS41 SSRSD41 SSRS41M1 SSRSD41M1 SRS41P14 SSRSD41P14 SRS41M1P14 SSRSD41M1P14 SRS42 SSSSSRSD42 SSSRS42M1 RSD42M1RS42P14 SSSRSD42P14 SSSSRS42M1P14
3 SRSD42M1P14 SRS43 SSRSD43 SRS43M1 RSD43M1RS43P14 SRSD43P14RS43M1P14 SRSD43M1P14RS44 SSSRSD44 SSRS44M1 RSD44M1RS44P14 SRSD44P14 SRS44M1P14 SRSD44M1P14 Complete line of Sockets Manual Operator / Bidirectional Green LED Pilot Light OptionsInput Vo l t ag eOptionsTypeSPDTS ilver CadmiumOxide ContactsAC50/60 HzNoneRS41*Manual OperatorRS41M1*Pilot LightRS41P14*Manual Operator and Pilot LightRS41M1P14*DCNoneRSD41*Manual OperatorRSD41M1*Pilot LightRSD41P14*Manual Operator and Pilot LightRSD41M1P14*Input Vo l t ag eOptionsTypeDPDTS ilver CadmiumOxide ContactsAC50/60 HzNoneRS42*Manual OperatorRS42M1*Pilot LightRS42P14*Manual Operator and Pilot LightRS42M1P14*DCNoneRSD42*Manual OperatorRSD42M1*Pilot LightRSD42P14*Manual Operator and Pilot LightRSD42M1P14*Input Volt ag eOptionsType3 PDTS ilver CadmiumOxide ContactsAC50/60 HzNoneRS43*Manual OperatorRS43M1*Pilot LightRS43P14*Manual Operator and Pilot LightRS43M1P14*DCNoneRSD43*Manual OperatorRSD43M1*Pilot LightRSD43P14*Manual Operator and Pilot LightRSD43M1P14*Input Vo l t ag eOptionsType4 PDTS ilver CadmiumOxide ContactsAC50/60 HzNoneRS44*Manual OperatorRS44M1*Pilot LightRS44P14*Manual
4 Operator and Pilot LightRS44M1P14*DCNoneRSD44*Manual OperatorRSD44M1*Pilot LightRSD44P14*Manual Operator and Pilot LightRSD44M1P14*How to Order:To Order Specify:Catalog Number Class Number Ty p e N u m b e r Voltage Code (See Stocked Relay Table to left)ClassTypeVoltage Code8501RS42V20 Type R Miniature Plug-in RelayGeneral and Order Information 2003-2008 Schneider ElectricAll Rights Reserved408/20088501 R Relays are suited for use as logic elements and power switching output devices. The short stroke motion of the armature provides long mechanical life required for high speed operation of control systems.
5 Different contact compositions allow these Relays to be used in a variety of applications. Fine silver (gold flashed) and bifurcated crossbar (gold overlay silver) are suitable for high contact reliability and low level switching requirements. Silver cadmium oxide is best suited for inductive loads. Hermetically sealed Relays can be used in adverse environments. 1, 3, or 5 Ampere Versions Horsepower Rated 4 PDT AC or DC Operation Complete Socket Line Manual Operator/Pilot Light Options Voltage code must be specified to order this product. Refer to standard voltage codes listed in the Stocked Relays table on page 5 and insert as shown in How To not ground frame.
6 Pilot Light OptionAn Internal green pilot light is available in both AC and DC versions for positive indication of power to the coil. The pilot lights are bidirectional LEDs. Manual Operation OptionTo speed circuit testing, a manual operator can be provided. The relay can be manually switched to simulate normal : All Type R Relays with a manual operator must be used on circuits of same polarity. h RS4/RSD4, RS14/RSD14 have C300 pilot duty Horsepower rating at 120 Data .. page 5 Wiring Diagrams .. page 6 Dimensions .. page 6 Sockets and Holddown Clips .. page 145 AInput VoltageOptionsTypeForswitchinginductive loadsContacts:Silver CadmiumOxideAC50/60 HzNoneRS14 Manual OperatorRS14M1 Pilot LightRS14P14 Manual Operatorand Pilot LightRS14M1P14 DCNoneRSD14 Manual OperatorRSD14M1 Pilot LightRSD14P14 Manual Operatorand Pilot LightRSD14M1P14 3 AInput VoltageOptionsTypeForlow levelswitchingContacts.
7 Fine Silver(Gold Flashed)AC50/60 HzNoneRS4 Manual OperatorRS4M1 Pilot LightRS4P14 Manual Operatorand Pilot LightRS4M1P14 DCNoneRSD4 Manual OperatorRSD4M1 Pilot LightRSD4P14 Manual Operatorand Pilot LightRSD4M1P14 1 AInput VoltageTypeBest for low level switchingAC 50/60 HzRS24 Bifurcated Silver Gold Plated ContactsDCRSD24 Hermetically SealedInput VoltageType5 Ampere Resistive qSilver Cadmium Oxide ContactsSuitable for Class I Division 2 LocationsAC 50/60 HzRS34 DCRSD34 Contact RatingsTypeVoltageContinuous Current RatingHorsepower RatingRS4 hRSD4 h120/240 VAC31/1030 VDC3 RS14 hRSD14 h120/240 VAC51/630
8 VDC5 RS24 RSD24120/240 VAC11/16 a30 VDC1 RS34 RSD34120/240 VAC5 30 VDC5 How to Order:To Order Specify:Catalog Number Class Number Ty p e N u m b e r Voltage Code (See Stocked Relay Table on page 5)ClassTypeVoltage Code8501RS4V208501 RS4V148501 RSD14P14V538501 RS14M1V14 Type R Miniature Plug-in RelayOrdering Information and Application Data508/2008 2003-2008 Schneider ElectricAll Rights Reserved S Stocked Factory Order items require a minimum order quantity of 25 and have a lead time of 12 weeks. When used with the appropriate 8501 NR RelaysTypeAC Voltage 50/60 HzTypeDC Voltage61224481202406122448110 Voltage CodeV35V36V14V17V20V24 Voltage CodeV50V51V53V56V60RS4 SSRSD4 SSRS4M1 SRSD4M1RS4P14 SRSD4P14 SRS4M1P14 SRSD4M1P14 SRS14 SSSRSD14 SSSRS14M1 SRSD14M1 SRS14P14 SRSD14P14 SSSRS14M1P14 SSRSD14M1P14 SSRS24 SRSD24 SRS34 SRSD34 SSClass 8501 TypeRS4 RSD4RS14 RSD14RS24 RSD24RS34 RSD34RS41 RSD41RS42 RSD42RS43 RSD43RS44 RSD44 Operating DataPick-UpTime25 ms Maximum13 ms ms MaximumDrop-Out Time25 ms Maximum6 ms ms MaximumOperating Temperature Range-40 C to +70 C(-40 F to)
9 +158 F)-45 C to +70 C(-49 F to +158 F)-40 C to +70 C(-40 F to +158 F)CoilDuty CycleContinuousVoltage RangeAC coils +10%, -15% of nominalDC coils +10%, -20% of nominalAC VA sealed VA sealed VA sealed VA sealed VA inrush, VA sealed VA inrush, VA sealed VA inrush, VA sealed VA inrush, VA sealed DC Coils watt watt watt watt watt watt watt wattFile CCNE197072 NRNT2N/AE78351 NLDX2E78427 NRNT2 File CCNE197072 NRNT8(Approved but not marked)E196809 NQMJ2, NQMJ8N/AFileClass2112683211 07N/A2112683211 07Ye sFile CCNE78351 NLDXE123950 NPKR, NPKR7E78351 NLDXN/A Type R Miniature Plug-in RelayDimensions and Wiring Diagram 2003-2008 Schneider ElectricAll Rights Reserved608/2008 Wiring Diagrams #3-48 NC-2A devices with manual #3-48 NC-2A (When Provided) (WhenProvided)(WhenProvided) (When Provided) (WhenProvided)(WhenProvided) (When Provided) (WhenProvided)(WhenProvided) (WhenProvided)(WhenProvided)(WhenProvide d)
10 , RSD42RS41, RSD41RS4, RSD4, RS14, RSD14, RS24, RSD24RS43, RSD43RS42, RSD42RS43, RSD43RS41, RSD41RS44, RSD44RS44, RSD44RS4, RSD4, RS14, RSD14, RS24,RS24, RSD24, RS34, RSD34 Dual Dimensions:MillimetersInchesRS34, RSD34 Type K - Plug-in RelayDimensions and Wiring Diagram708/2008 2003-2008 Schneider ElectricAll Rights Reserved8501 K Relays are designed for multipole switching applications at 240 volts or lower. These Relays have industry standard wiring and pin arrangements which allows for their use as replacements for many similar Relays without wiring or hardware modifications.