Example: biology

SSR UP5 22E, UP5 30, SSR M37PE 50Hz

SSR UP5 22E, UP5 30, SSR M37PE50 HzOPERATION AND MAINTENANCE MANUALThis manual containsimportant safety informationand must be made availableto personnel who operate andmaintain this UP5 22E >50Hz UP5 30 >2245000227500050Hz M37PE 37 >SERIAL No :SERIAL No :SERIAL No : 22255426 GBREV.: BDATE: OCTOBER 200309/03 Machine models represented in this manual may be used in various locations world wide. Machines sold andshipped into European Union Territories require that the machine display the EC Mark and conform to variousdirectives. In such cases, the design specification of this machine has been certified as complying with EC modification to any part is absolutely prohibited and would result in the CE Certification and marking beingrendered invalid.

15 93165959 6 Decal, use guards when running 16 32343097 1 Decal, voltage 380– 415/3/50 32343105 1 Decal, voltage 220/3/50 32343113 1 Decal, voltage 550/3/50 17 32343089 1 Decal, wiring schematic Star Delta 50Hz 18 22062319 1 Tag, Air Care do you know 19 22115661 1 Tag, rotation 50Hz 20 32344095 2 Tag, shipping bracket

Tags:

  Running

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SSR UP5 22E, UP5 30, SSR M37PE 50Hz

1 SSR UP5 22E, UP5 30, SSR M37PE50 HzOPERATION AND MAINTENANCE MANUALThis manual containsimportant safety informationand must be made availableto personnel who operate andmaintain this UP5 22E >50Hz UP5 30 >2245000227500050Hz M37PE 37 >SERIAL No :SERIAL No :SERIAL No : 22255426 GBREV.: BDATE: OCTOBER 200309/03 Machine models represented in this manual may be used in various locations world wide. Machines sold andshipped into European Union Territories require that the machine display the EC Mark and conform to variousdirectives. In such cases, the design specification of this machine has been certified as complying with EC modification to any part is absolutely prohibited and would result in the CE Certification and marking beingrendered invalid.

2 A declaration of that conformity follows:EC DECLARATION OF CONFORMITY WITH EC DIRECTIVES98/37/EC, 97/23/EC, 93/68/EEC, 89/336/EECWE,INGERSOLL RAND COMPANY LIMITEDSWAN LANEHINDLEY GREENWIGAN WN2 4 EZUNITED KINGDOMDECLARE THAT, UNDER OUR SOLE RESPONSIBILITY FOR MANUFACTURE AND SUPPLY,THE PRODUCT(S)SSR UP5 22E, UP5 30, SSR M37 PETO WHICH THIS DECLARATION RELATES, IS (ARE) IN CONFORMITY WITH THE PROVISIONSOF THE ABOVE DIRECTIVES USING THE FOLLOWING PRINCIPAL , EN292, EN60204 1, EN1012, EN50081, EN50082 ISSUED AT HINDLEY GREEN ON 01/01/2003 BY , QUALITY SEDDONAIR COMPRESSOR GROUPBONDED WARRANTY & REGISTERED START UPWarrantyThe Company warrants that the equipment manufactured by it and delivered hereunder will be free of defects inmaterial and workmanship for a period of twelve months from the date of placing the Equipment in operation or eighteenmonths from the date of shipment from the factory, whichever shall first occur.

3 The Purchaser shall be obligated topromptly report any failure to conform to this warranty, in writing to the Company in said period, whereupon theCompany shall, at its option, correct such nonconformity, by suitable repair to such equipment or, furnish a replacementpart point of shipment, provided the Purchaser has stored, installed, maintained and operated such Equipmentin accordance with good industry practices and has complied with specific recommendations of the or equipment furnished by the Company, but manufactured by others, shall carry whatever warranty themanufacturers have conveyed to the Company and which can be passed on to the Purchaser.

4 The Company shallnot be liable for any repairs, replacements, or adjustments to the Equipment or any costs of labor performed by thePurchaser or others without Company s prior written approval. The effects of corrosion, erosion and normal wear and tear are specifically excluded. Performance warranties arelimited to those specifically stated within the Company s proposal. Unless responsibility for meeting such performancewarranties are limited to specified tests, the Company s obligation shall be to correct in the manner and for the periodof time provided COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER,EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY by the Company of nonconformities whether patent or latent, in the manner and for the period of timeprovided above, shall constitute fulfillment of all liabilities of the Company for such nonconformities whether based oncontract, warranty negligence.

5 Indemnity, strict liability or otherwise with respect to or arising out of such purchaser shall not operate Equipment which is considered to be defective, without first notifying the Companyin writing of its intention to do so. Any such use of Equipment will be at Purchaser s sole risk and that this is Ingersoll Rand standard warranty. Any warranty in force at the time of purchase of the compressoror negotiated as part of the purchase order may take precedence over this on line at Rand European Sales CompanySwan LaneHindley GreenWigan WN2 4 EZUnited KingdomPhone: +44 (0)1942 257 171 Ingersoll Rand Asia PacificC/O Ingersoll Rand SEA (Pte) Ltd. 42 Benoi Road Singapore 629903 Phone: +65 8611555 & ABBREVIATIONS1 SSR UP5 22E, UP5 30, SSR M37 PECONTENTS1 CONTENTS2 FOREWORD3 DECALS6 SAFETY8 GENERAL INFORMATION12 INSTALLATION / HANDLINGOPERATING INSTRUCTIONS18 GENERAL19 ELECTRO PNEUMATIC23 INTELLISYS31 MAINTENANCE38 TROUBLE SHOOTINGABBREVIATIONS & SYMBOLS####Contact Ingersoll Rand for serial number >####Up to Serial No.

6 #### >From Serial No.*Not illustrated{OptionNRNot requiredARAs requiredSMSitemaster/SitepackHAHigh ambient machineWCWatercooled machineACAircooled machineERSE nergy recovery enclosed fan cooled motor (IP55) drip proof (motor)BRPortuguese (Brazil)CAFrench (Canada)CNChineseDEGermanDKDanishESSpani shFIFinnishFRFrenchGBEnglish (Europe)GRGreekITItalianMXSpanish (Mexico)NLDutchNONorwegianPTPortuguese (Europe)SESwedishUSEnglish (USA)FOREWORD2 SSR UP5 22E, UP5 30, SSR M37 PEThe contents of this manual are considered to be proprietary andconfidential to Ingersoll Rand and should not be reproduced withoutthe prior written permission of Ingersoll contained in this document is intended to extend anypromise, warranty or representation, expressed or implied, regardingthe Ingersoll Rand products described herein.}

7 Any such warranties orother terms and conditions of sale of products shall be in accordancewith the standard terms and conditions of sale for such products, whichare available upon manual contains instructions and technical data to coverroutine operation and scheduled maintenance tasks by operation andmaintenance staff. Major overhauls are outside the scope of thismanual and should be referred to an authorised Ingersoll Rand design specification of this machine has been certified ascomplying with directives. Any modification to any part isabsolutely prohibited and would result in the CE certification andmarking being rendered components, accessories, pipes and connectors added to thecompressed air system should be.

8 Of good quality, procured from a reputable manufacturer and,wherever possible, be of a type approved by Ingersoll rated for a pressure at least equal to the machine maximumallowable working with the compressor with instructions for safe installation, operation of approved equipment are available from Ingersoll RandService use of non genuine spare repair parts other than thoseincluded within the Ingersoll Rand approved parts list may createhazardous conditions over which Ingersoll Rand has no Ingersoll Rand does not accept any liabilitity for lossescaused by equipment in which non approved repair parts are warranty conditions may be Rand reserves the right to make changes andimprovements to products without notice and without incurring anyobligation to make such changes or add such improvements toproducts sold intended uses of

9 This machine are outlined below and examplesof unapproved usage are also given, however Ingersoll Rand cannotanticipate every application or work situation that may IN DOUBT CONSULT machine has been designed and supplied for use only in thefollowing specified conditions and applications:.Compression of normal ambient air containing no known ordetectable additional gases, vapours. or within the ambient temperature range specified in theGENERAL INFORMATION section of this use of the machine in any of the situation types listed intable 1: a) Is not approved by Ingersoll Rand,b) May impair the safety of users and other persons, andc) May prejudice any claims made against Ingersoll 1 Use of the machine to produce compressed air for.

10 A) direct human consumptionb) indirect human consumption, without suitable filtration and of the machine outside the ambient temperature rangespecified in the GENERAL INFORMATION SECTION of this of the machine where there is any actual or foreseeable risk ofhazardous levels of flammable gases or MACHINE IS NOT INTENDED AND MUST NOT BEUSED IN POTENTIALLY EXPLOSIVE ATMOSPHERES,INCLUDING SITUATIONS WHERE FLAMMABLE GASES ORVAPOURS MAY BE of the machine fitted with non Ingersoll Rand of the machine with safety or control components missing company accepts no responsibility for errors in translation ofthis manual from the original English version.


Related search queries