Category 2 & 3 owner s Manual WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. Tested and Listed by Report # 0028GF103S ANSI / CSA Gas-Fired Domestic and Commercial Heating Equipment Vented Gas Fireplace This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.

2 Introduction © Travis Industries 4160122 100-01418 Overview This manual details the DaVinci category 2 fireplace. Listing Details This appliance was listed by Omni-Test

Tags:

  Manual, Owner, S manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Category 2 & 3 Owner’s Manual - Custom Fireplace

1 Category 2 & 3 owner s Manual WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. Tested and Listed by Report # 0028GF103S ANSI / CSA Gas-Fired Domestic and Commercial Heating Equipment Vented Gas Fireplace This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.

2 This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. INSTALLER: Leave this Manual with the appliance. CONSUMER: Retain this Manual for future reference. Travis Industries, Inc. 12521 Harbour Reach Dr., Mukilteo, WA 98275 Copyright 2016, $ 4160122 100-01418 PortlandOregon USAT ested &Listed By2 Introduction Travis Industries 4160122 100-01418 Overview This Manual details the DaVinci Category 2 Fireplace . Listing Details This appliance was listed by Omni-Test Laboratories, Inc. to ANSI / CSA The listing label is chained to the appliance near the glass frame.

3 A copy is shown to the right. Massachusetts Approval This Manual has been submitted to the Massachusetts Board of State Examiners of Plumbers and Gas Fitters National Fireplace Institute Dealer Information Please record your dealer information here for future reference: Dealer Name: _____ Dealer Address: _____ Dealer E-Mail: _____ Dealer Phone #: _____ Report No. 0028GF103 SCertified for USA and CanadaPortlandOregon USAT ested &Listed ByVented Gas Fireplace HeaterDaVinci to: ANSI / Certified to: CSA Gas-Fired Domestic and Commercial Heating Equipment Vented Gas Fireplace This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI 54, or Natural Gas and Propane Installation Codes, CSA appliance must be installed in accordance with the Standard for Manufactured Homes, CAN/CSA Z240 MH Series, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or when such a standard is not applicable, the Standard for Fire Safety Criteria for Manufactured Home Installations, Sites and Communities, NFPA 501 AThis vented gas Fireplace heater is equipped at the factory for use with gas fuel marked above.

4 No conversion is appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. See owner s Manual for details. This appliance is not convertible for use with other gases, unless a certified kit is vented gas Fireplace heater is not for use with air burner and control compartment clean. See installation and operating instructions accompanying appliance must be properly connected to a venting system in accordance with the manufacturer s installation instructions. See owner s Manual for approved brands of : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

5 Refer to the owner s information Manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas GAS Fireplace HEATER - NOT FOR USE WITH SOLID FUELM inimum Clearances to CombustiblesFireplace to Adjacent WallWood Floor Beneath FireplaceBack to Enclosure1 (26mm)0 (0mm)0 (0mm)Top to EnclosureSides to EnclosureBase of Fireplace to a (140mm)0 (0mm)See owner s ManualElectrical Rating: 120V., 60 Hz., Less than AmpsDANGER! Risk of Electric Shock. Disconnect power before servicing Inlet Pressure (inches )Maximum Inlet Pressure (inches )Manifold Pressure on HI (inches ) 13 10 7 This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m).

6 For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be owner s Manual for information on making these Rate on HI (BTU/Hr)Orifice Sizes - (DMS) # # DATE:WARNING: Failure to install this appliance per the manufacturer s instructions or failure to use only parts specifically approved with this appliance may result in property damage or personal Harbour Reach DriveMukilteo, WA 98275 Manufactured :Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service Table of Contents 3 Travis Industries 4160122 100-01418 Overview .. 2 Listing Details .. 2 Installation Options .. 6 BTU Specifications .. 6 Fireplace Modules .. 6 Decimal Conversions.

7 6 Category 2 Dimensions Single Sided or See Through Configurations .. 7 Category 2 Dimensions Pier Configuration .. 8 Category 2 Dimensions Island Configuration .. 9 Category 2 Dimensions Full Bay Configuration .. 10 Category 2 Dimensions Right Side Corner Configuration .. 11 Category 2 Dimensions Left Side Corner Configuration .. 12 Category 3 Dimensions Single Sided or See Through Configurations .. 13 Category 3 Dimensions Pier Configuration .. 14 Category 3 Dimensions Island Configuration .. 15 Category 3 Dimensions Full Bay Configuration .. 16 Category 3 Dimensions Right Side Corner Configuration .. 17 Category 3 Dimensions Left Side Corner Configuration .. 18 Packing List for Fireplace Modules .. 19 Joining Components .. 20 Recommended Specialty Tools.

8 20 Recommended Installation Procedure .. 21 Massachusetts Requirements .. 23 Alignment Track Installation .. 24 Place the Fireplace on the Alignment Track .. 25 Remove the Shipping End Caps from Fireplace Modules .. 25 Remove Components to Allow for Fireplace Joining .. 26 Slide the Fireplace Modules Together .. 29 Install Upper Titan Lock Braces (do not fully tighten) .. 30 Install Lower Titan Lock Braces (do not fully tighten) .. 31 Place Installation Alignment Tool in Center of Glass Opening and Adjust .. 32 Attach Tension Rods .. 33 Tightening the Titan Lock Connectors .. 34 Remove the Installation Alignment Tool(s) .. 34 Secure the Fireplace to the Alignment Track .. 35 Attach the Gas and Electrical Lines Between the Fireplace Modules .. 36 Pressure Switch Tube Installation ( Category 3 Only).

9 38 Fireplace Placement Requirements .. 39 Typical Framing Dims. One Sided Configuration .. 40 Typical Framing Dims. See Through Configuration .. 41 Typical Framing Dims. Pier Configuration .. 42 Typical Framing Dims. Island Configuration .. 43 Typical Framing Dims. Full Bay Configuration .. 44 Typical Framing Dims Right-Sided Corner .. 45 Typical Framing Dims Left-Sided Corner .. 46 Nailing Brackets .. 47 Accessing Internal Components .. 48 Gas Line Requirements .. 51 Electrical Junction Box .. 53 Electrical Input Connection .. 55 Connecting the Power Vent Lead to the Fireplace .. 56 Connecting the Exhaust Damper Harness to the Fireplace .. 57 Wiring the Power Vent .. 58 Wiring the Power Vent (continued) .. 59 Connecting the Intake Damper Harness to the Fireplace .

10 60 Wiring the Intake Damper .. 61 Connecting the On-Off LED Harness to the 62 Installing the On-Off Switch and LED Controller .. 63 Air Intake Requirements .. 64 Air Intake Duct Quantity and Location Category 2 .. 66 Air Intake Duct Quantity and Location Category 3 .. 67 Air intake Installation Hood Versions (includes external dampers) .. 68 Internal Dampers (for Hori. or Vert. Termination) .. 69 Vent Requirements .. 70 Approved Vent Configurations .. 71 Power Vent Dimensions and Framing .. 74 Hearth Requirements .. 81 Facing Requirements .. 81 Mantel Requirements .. 82 Fireback Installation .. 83 Glass Pane Installation and Removal .. 88 Steps for Finalizing the Installation .. 91 Crushed Glass Installation .. 92 Wiring Diagram .. 94 Before You Begin .. 95 Starting the Heater for the First Time.