Transcription of Central Station Air Handlers Indoor & Outdoor - …
1 Bulletin9E 1/08 Central StationAir HandlersIndoor & Outdoor2 Custom & ReplacementAir Handling UnitsUnique Replacement Engineeringand quality designcreates the perfect SpecialistsUSA Coil & Air has been an industry leader in buildingair Handlers for both new and replacement applications fordecades. We bring all the newest technology to both thedesign and performance of our Central Station air handlingunits, and we offer extensive experience in design-buildand retrofit builds units that are a cross between standard airhandlers and custom units. We offer all kinds of optionsand accessories that allow you to semi-customize yourunit.
2 You can vary dimensions, add special sections, usepainted or galvanized sections, and just generally designthe unit that you need for your job. And the best part is thatyou re not paying for a total custom unit. You re gettingmost of what you want at standard unit can tailor our selection to meet your software is designed to offer you the equivalent of acomplete submittal at the time of our proposal to you. Youwill get complete performance, dimensions and choices inoptions and accessories. You will have a menu to choosefrom, so that you can design the unit that fits your spaceand meets your requirements for your specific , many existing units fail to meet revised conditionsor systematic conditions that might mean that you requirenew units to do your job.
3 USA has a wealth of experiencein retrofit/replacement and nobody can do a better job ofwalking you through the design of your new unit. We offersuggestions and engineering recommendations that cre-ate better performance, higher efficiency and longevity. Callus and we will be happy to work with you on your DRAW THRU DOUBLE WALL UNIT USA Coil & Air, 20073 Access Panels and Doors strategically located toallow for proper service and maintenance of unitary com-ponents. Extended Fan Bearing Lube Lines and Coil Con-nections to easily maintain drain lines and keep air mov-ing equipment Design Modular Design that allows you to mix and matchsections to essentially build an air handler your way!
4 Flexible Dimensioning gives you the ability to de-sign a unit and its components in a box size that meetsthe dimensional criteria of the installation. Indoor and Outdoor Construction available. If it ison a platform, pad, steel or a curb, then we have a unit tomeet your exacting , Low Cost Installation Bolted Frame Construction with easy to remove pan-els Simple Section Attachment via patented splicingdesign Gasketed Extended Coil Connections and DrainPan Connections that eliminate constant panel remov-able and guaranteed air tight Efficiency Computer selected Components provide the high-est efficiency at a reasonable first cost basis.
5 Solid or Perforated Double Wall Liners reduce con-densation and air leakage Double wall injected foam insulation increasespanel strength and R-value of R-13 Easy Service and Maintenance Special Access Sections can be located betweenany system components allowing walk in space or changeany item. Low Leak Cabinet Design means you re providingheated or cooled air to the intended space and not to aremote area. Low Leak Dampers reduce operating costs and sim-plify installation. Huge Offering of Adaptable Inlet and Outlet Sec-tions that minimize the attachment of ductwork and re-duces labor costs Complete Drive Side Assembly to include customfan, motor drive and vibration isolation mounted and fac-tory tested on a unit mounted steel base.
6 Galvanized Steel Cabinets or Painted Steel whichoffers a quality option if a smooth appearance is required. Ship Assembled or In Sections gives the installerthe ability to move units into place quickly and design is always a possibility to move units throughbuilding openings to include fresh air, doorways, elevatorsand stairs. In really tight areas, each section can be to-tally knocked down and reassembled on Shipping SchedulesMany projects require some form of quick shipment whenyou need units for design-build or units for shipment is often your first thought. How do I getthe units on the job quickly?
7 USA offers quick ships on many of our units. Often weship Central stations within a month. We can t offer everyoption or accessory under this program, because that justwouldn t be practical. We can t always do it, just based onscheduling and backlog. USA, however, does a great jobof shipping quick when it s possible. If we can help yousolve your problem with our quick ship program, then Features - Indoor UnitsQualityFor many years USA Coil & Air has been respected andhighly regarded for their fast shipment of high quality air han-dling equipment. USA has taken a major step forward in re-defining the Indoor Central Station air handler.
8 Demands forimproved Indoor air quality, low sound, high operating effi-ciency and smaller mechanical rooms require a better prod-uct for today s air handler market. The USA Indoor CentralStation air handler has been designed to meet or exceedthese key to providing such a high quality product is in thebasic design. The USA Indoor Central Station s unique con-struction has been designed to provide unequaled thermalefficiencies and to be airtight. In addition, USA Indoor AirHandlers offer tremendous flexibility in sizing, componentoptions and unit arrangements to meet the Indoor air qualityrequirements, operating efficiency, sound and installationrequirements for today s extensive commercial and virtue of its unique frame design, the USA Indoor AirHandler offers incredible flexibility.
9 This is reflected in ourVariable Increment feature that allows USA air Handlers tobe sized in two-inch increments (height and width) to fit theavailable space. Numerous section and component options,and the ability to arrange components in whatever arrange-ment required, allow USA air Handlers to be customized tothe requirements of each job without expensive field modifi-cations. Finally, USA air Handlers can be shipped as a com-pletely assembled unit, in modules or by component sec-tions for new or retrofit applications that require smaller sec-tions for passage through the ConstructionUSA Indoor Air Handler cabinetry consists of a box-typeframe channel - the backbone of the unit - and easy-to-re-move panels or hinged access doors.
10 The unique, patentedframe channel design allows three identical pieces to be boltedtogether to form a corner of the unit. Channels are formed ofG90 galvanized steel or G60 painted galvanized with factoryapplied neoprene gasketing on all flanges to minimize ther-mal leakage. Gasketing is also factory applied at all contactsurfaces between interior and exterior metal components tominimize thermal bridging. Panels are secured to the unitwith fasteners that can be easily removed to access the unitinterior. The frame channel and panels can be easily disas-sembled and reassembled, giving contractors tremendousflexibility in installing and servicing the units - even wherespace is very limited - saving time and money.