PLYMOU T HSTEAM IIPLYMOU T HSTEAM IINATURAL OR PROPANE GAS-FIRED BOILERSA merica's Hottest BoilerValue! An ISO 9001-2000 Certified CompanyDunkirk QualitySince 1928, American-made DunkirkBoilers have been leading the industryin value and reliability with innovativedesigns and premium quality components. Assured performance has placed Dunkirk quality at the topin trusted reliability ( *). Every gas boiler we manufacture is test fired prior to shipment. This boiler is certified by in theUnited States; heat exchangers by ASME; andefficiency ratings by the Hydronics PLYMOUTH Steam II Boiler by Dunkirk offersthe best combination of heating comfort, efficiency, and affordability, makingit one of America s Hottest Boiler EfficiencyThe high efficiency of the PLYMOUTH steamboiler renders outstanding performanceand low operating Ignition (Option) Pilot is lit automatically and stays litonly when needed, eliminating fuel Draft DiverterDunkirk utilizes built-in draft divertertechnology that is factory designed to protectagainst harmful carbon monoxide back competitor diverters erected in-field, Dunkirk eliminates any installation guessworkto ensure your family s Vent Damper Automatically closes when the unit turns off,preventing heated air from escaping up thechimney.

PLYMOUTH STEAM II NATURAL OR PROPANE GAS-FIRED BOILERS America'sHottestBoilerValue! ® An ISO 9001-2000 Certified Company

Tags:

  Plymouth

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of PLYMOUTH TEAM II - Dunkirk

1 PLYMOU T HSTEAM IIPLYMOU T HSTEAM IINATURAL OR PROPANE GAS-FIRED BOILERSA merica's Hottest BoilerValue! An ISO 9001-2000 Certified CompanyDunkirk QualitySince 1928, American-made DunkirkBoilers have been leading the industryin value and reliability with innovativedesigns and premium quality components. Assured performance has placed Dunkirk quality at the topin trusted reliability ( *). Every gas boiler we manufacture is test fired prior to shipment. This boiler is certified by in theUnited States; heat exchangers by ASME; andefficiency ratings by the Hydronics PLYMOUTH Steam II Boiler by Dunkirk offersthe best combination of heating comfort, efficiency, and affordability, makingit one of America s Hottest Boiler EfficiencyThe high efficiency of the PLYMOUTH steamboiler renders outstanding performanceand low operating Ignition (Option) Pilot is lit automatically and stays litonly when needed, eliminating fuel Draft DiverterDunkirk utilizes built-in draft divertertechnology that is factory designed to protectagainst harmful carbon monoxide back competitor diverters erected in-field, Dunkirk eliminates any installation guessworkto ensure your family s Vent Damper Automatically closes when the unit turns off,preventing heated air from escaping up thechimney.

2 Effikal provides the strongest ventdamper warranty in the s exclusivehigh-tech titaniumcomposite burnersresist corrosion andoxidation while with-standing more heat than conventional stainless steel or aluminizedburners. They provide superior strength andlongevity and are backed by a full 3-year warranty,triple the industry Iron Sections& Push NipplesDunkirk utilizes castiron to construct the boiler s heatexchanger to provide heat transfer,reliability and strength. Since like materials expand and contract in the sameproportion during heating and cooling, cast iron push nipples and sections producestronger, more water-tight seals than steelpush nipples or rubber InstallationSurprisingly compact, the PLYMOUTH Steam IIBoiler fits in tight spaces and is suppliedassembled, with controls that are accessibleand completely wired. Piping is also at hand for easy connection to the MaintenanceLow water cutoff is electronic, therefore, results in minimal homeowner are easily accessible without havingto remove the jacket, and our standard controls are readily available, making DunkirkBoilers easy to T HSTEAM IINATURAL OR PROPANE GAS-FIRED BOILERSE fficiency as High as Warranty in the IndustryDunkirk backs all of its residential castiron steam boilers with afull twelve year warrantycovering the entire heat competitor s warranties coverheat exchanger sections only and mostlast for 10 years.

3 *Data on file - Dunkirk BoilersFEATURES & BENEFITSPLYMOUTH STEAM STANDARD EQUIPMENTP(V) SB SERIESSTANDARD EQUIPMENT Assembled boiler with insulated jacket Two 2-1/2" supply tappings and two 2-1/2" return tappings. Integral draft diverter built into jacket 24 volt, 40VA transformer Pressure limit control Electronic probe type low water cut off Flame rollout safety shut-off fuse link and blocked vent safety shut-off switch with spare fuse link included Sight Glass Water Level Gauge Steam pressure gauge 3/4" boiler drain valve 15 lb. ASME pop safety valve Two 2-1/2 square head pipe plugs to plug unused supply and return tappings Vent damper Complete installation instructions Completely installedand wired gas control systems withburners and manifold, consisting of: Titanium composite burners Automatic redundant combination gas valve, 24 voltELECTRONIC IGNITION ONLY: Intermittent Pilot Control, continuous re-try, 100% shut off Combination pilot burner/electrode/flame sensorSTANDING PILOT ONLY: Pilot burner & thermocoupleOPTIONAL EQUIPMENT Combustible floor plate 14614031 for 3-6 section.

4 14614032 for 7-9 section Electronic Water Feeder Natural to propane conversion kit (when ordering kit, please provide serial number of boiler to be converted) Vent DamperAutomatically closes when unit turns off preventing heat Draft Diverterprovides safety from backdrafts and accommodateslow ceiling directly to fluepipe from top of Iron QualityProvides effective heat transfer, reliability and orStanding Pilot IgnitionOptional electronic ignitionautomatically lights the pilotonly when needed,eliminating fuel BurnersDunkirk s exclusive burnersprovide greater resistance tocorrosion and 15% more heatthan conventional burnerson competitive operating control prevents the boiler frombuilding pressure levelsbeyond recommended limits. Will shut down the boiler if receives the 120 voltpower from the building selectrical service and steps it down to 24 volt Sight GlassAllows for easy viewing ofthe boiler s water Water Cut-OffElectronically monitors thewater level in the heatexchanger shutting the unit off if the water level is too EnamelSteel JacketFactory installed insulationkeeps off-cycle heat losses to a minimum in an attractive and compact "111/4" "141/2" "173/4" "21" "241/4" "271/2" "303/4" BOILER UNIT PILOTW/ DAMPERE/I PILOTW/ DAMPERNUMBEROFSECTIONSAGAINPUT MBHHEATINGCAPACITY MBH NATURAL GAS PROPANE GASDIMENSIONSPVSBW/ Steam IIFLUEDIAMETER"A"WIDTHNETI=B=R MBHNET I=B= EDRAGAINPUT MBHHEATINGCAPACITY MBHNETI=B=R MBHNET I=B= EDR The ratings marked Net I=B=R Ratings represent the heat available tothe radiation or terminal units.

5 The Net I=B=R Ratings shown are basedon an allowance of in accordance with the factors shown in theI=B=R Code as published by The Hydronics Institute. Selection of boiler size should be based upon Net I=B=R Rating beingequal to or greater than the installed radiation in square feet EDR. Consult manufacturer before selecting a boiler for installations havingunusual piping and pick-up requirements. These boilers may be installed on combustible flooring when placed on combustible floor plate. These gas-fired boilers are sectional cast iron boilers design certified by in the for use with natural gas and propane gas. They are constructed and hydrostatically tested for a maximum working pressureof 50 psi in accordance with (American Society of MechanicalEngineers) Boiler And Pressure Vessel Code Section IV standardsfor cast ironheatingboilers. They are capacity rated in accordance with the code ofThe Hydronics Institute.

6 MBH = 1,000 BtuhBtuh = BRITISH THERMAL UNIT PER HOUR FOR ALL ALTITUDES ABOVE 2,000 FEET RATINGS SHOULD BE REDUCED AT THE RATE OF 4% FOR EACH 1,000 FEET ABOVE SEA YORK CITY MEA NUMBER 77-91-E RATINGS IN SQUARE FEET ARE COMPARED AT 240 BTUh / SQUARE FOOT FOR STEAM BOILERSHEATING CAPACITY BASED ON (DEPARTMENT OF ENERGY) TEST PROCEDURE.*ADD 5-1/2" TO HEIGHT FOR VENT DAMPER EDR= EQUIVALENT DIRECT RADIATIONNATURAL OR PROPANE GAS-FIRED STEAM BOILERSRATINGS & CAPACITIESASMEPOPSAFETYVALVE29"12-1/4"LE FT SIDE2-1/2" NPTVENT *DAMPERPRESSUREGAUGELOWWATERCUT-OFFPROBE GAS LINEFRONTAWATER LINE36-3/8" *RIGHT SIDELOWWATERCUT-OFF TRANSFORMERGLASSGAUGE24"2-1/2"4-3/4"26-1 /2"S86 GASVALVE Tested for 50 Working PressureSpecifications and dimensions are subject to change without in America by American QUALITY HEATING. AMERICA S HOTTEST BOILER VALUE! Dunkirk hydronic boilers lead the industry in value, with premium quality design and componentry.

7 In fact, some of the most respected brand name boilers are produced by Dunkirk . These major manufacturers selected Dunkirk hydronic boilers for the same basic reasons you should: superbquality and unmatched value. Just compare our quality to cost ratio, and your boiler choice will become perfectly 1928. America s Hottest Boiler MIDDLE RD Dunkirk ,NY 14048716/366-5500 FAX 866/432-7329e-mail: site: 1/07 An ISO 9001-2000 Certified CompanyECRI nternationalAnBrandUSA Homeowner Assistance: 866-847-6656 USA Contractor Technical Assistance: 800-325-5479