Example: quiz answers

½” Slot • Insulated ML/MLR - Titus HVAC | …

SubmittalModulinear Plenum Adapters for ML Modulinear DiffusersModels: MP-37 SlotMPI-37 Slot Insulated MP-38 SlotMPI-38 Slot Insulated MP-39 1" SlotMPI-39 1 Slot Insulated MP-40 1 " SlotMPI-40 1 " Slot InsulatedMP 8-30-13 Dimensions are in Oval6 1/45 1/48 Oval9 3/85 1/410 Oval12 1/25 1/412 Oval14 1/87 7/8 DimensionsStandard Inlet SizeHW 1 1/8"1/2"LABI nternalOptionalInsulation(MPI Models)Standard InletsNominal Length (N)in f eet2, 3 6, 86, 84, 5, 6 6, 8, 106, 8, 10, 12 Low Prof ile (LP) Units Oval (in.)

Submittal Modulinear Plenum Adapters for ML Modulinear Diffusers Models: MP-37 • ½” Slot MPI-37 • ½” Slot • Insulated MP-38 • ¾” Slot MPI-38 • ¾” Slot • Insulated

Tags:

  Hvac, Insulated, Titus, Lost, Titus hvac, Slot insulated

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of ½” Slot • Insulated ML/MLR - Titus HVAC | …

1 SubmittalModulinear Plenum Adapters for ML Modulinear DiffusersModels: MP-37 SlotMPI-37 Slot Insulated MP-38 SlotMPI-38 Slot Insulated MP-39 1" SlotMPI-39 1 Slot Insulated MP-40 1 " SlotMPI-40 1 " Slot InsulatedMP 8-30-13 Dimensions are in Oval6 1/45 1/48 Oval9 3/85 1/410 Oval12 1/25 1/412 Oval14 1/87 7/8 DimensionsStandard Inlet SizeHW 1 1/8"1/2"LABI nternalOptionalInsulation(MPI Models)Standard InletsNominal Length (N)in f eet2, 3 6, 86, 84, 5, 6 6, 8, 106, 8, 10, 12 Low Prof ile (LP) Units Oval (in.)

2 High Prof ile (HP) Units Oval (in.)Note: End caps not H1 1/8"1/2"ALB(MPI Models)InternalOptionalInsulationML/MLRE ndLFabricationXXN-7/8 XYN-7/8 YYN-1/4 ZZN-1/4 Standard InletsNominal Length (N)in f eet2, 3 6, 86, 84, 5, 6 6, 8, 106, 8, 10, 12 Low Prof ile (LP) Units Oval (in.)High Prof ile (HP) Units Oval (in.)AB6 Oval6 1/45 1/48 Oval9 3/85 1/410 Oval12 1/25 1/412 Oval14 1/87 7/8 DimensionsStandard Inlet SizeHLPHP(in.)7 5/810 5/8 Note: End caps not 7/162 11/163 15/165 3/166 7/167 11/168 15/1610 3/16MP-381 11/163 3/164 11/166 3/167 11/169 3/1610 11/1612 3/16MP-391 15/163 11/165 7/167 3/168 15/1610 11/1612 7/1614 3/16MP-402 7/164 11/166 15/169 3/16N/AN/AN/AN/AML/MLR TypeWidthNum ber of Slots12345678MP-372 3/163 7/164 11/165 15/167 3/168 7/169 11/1610 15/16MP-382 7/163 15/165 7/166 15/168 7/169 15/1611 7/1612 15/16MP-392 11/164 7/166 3/167 15/169 11/1611 7/1613 3/1614 15/16MP-403 3/165 7/167 11/169 15/16N/AN/AN/AN/AML/MLR TypeWidthNumber of SlotsModel MP Modulinear Plenum for ML/MLRB order

3 TypeModel MP Modulinear Plenum for ML/MLRB order TypeHLPHP(in.)8112A2 BMP 8-30-13 Accessories (optional)This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written rights reserved. No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Description Model MP modulinear plenums are tailored for field attachment to ML or MLR modulinear diffusers.

4 Can be selected to integrate with all ML or MLR frame and border types. Standard lengths are 2 , 3 , 4 , 5 and 6 . End caps can be turned up to allow installing the MP on continuous runs of ML diffuser. Available with optional internal insulation, Model MPI. Model MP can be used as supply or return. Available to fit ML or MLR 1-8 slot units. Material is DetailsInternal InsulationL1 1/8W Insulation(MPI Models)H1/2 ABOptionalInternalModel MP Modulinear Plenum for ML/MLRB order Type3467A7B11ML/MLREndLFabricationXXN-1/ 4 XYN-1/4 YYN-1/4 ZZN-1/4 Standard InletsNominal Length (N)in feet2, 3 6, 8, 106, 8, 104, 5, 6 6, 8, 106, 8, 10, 12 Low Profile (LP) Units Oval (in.)

5 High Profile (HP) Units Oval (in.)AB6 Oval6 1/45 1/48 Oval9 3/85 1/410 Oval12 1/25 1/412 Oval14 1/87 7/8 Dim e ns ionsStandard Inlet SizeHLPHP(in.)7 5/810 5/8 Note: End caps not Type 2A, 2 BFrame & Border Types 3, 4, 6, 7A, 7B,11W=Duct Size Concealed Mounting1/8" to 1/2"W =Duct Size MPI-37 For ML/MLR -37 SlotMPI-38 For ML/MLR -38 SlotMPI-39 For ML/MLR -39 1 SlotMPI-40 For ML/MLR -40 1 SlotModel ID Inlet DamperNote: Inlet damper is shipped loose for field "Border Type 1A, 1B, 9A, 9B, 12, 15, 2212345678MP-372 3/163 7/164 11/165 15/167 3/168 7/169 11/1610 15/16MP-382 7/163 15/165 7/166 15/168 7/169 15/1611 7/1612 15/16MP-392 11/164 7/166 3/167 15/169 11/1611 7/1613 3/1614 15/16MP-403 3/165 7/167 11/169 15/16N/AN/AN/AN/AML/MLR TypeWidthNum ber of Slots