Example: stock market

SPECIFICATION & INSTALLATION OVERVIEW

SPECIFICATION & INSTALLATION OVERVIEW REMOTE ELECTRICAL ANCILLARIES ELECTRICAL ANCILLARIES MODELS AVAILABLE For fans designed for remote switch operation Unobtrusive, attractive designs, manufactured in polycarbonate thermo-plastic Comply with relevant EMC directives All remote controllers can be flush or surface mounted using a standard single gang box Code Model Dimensions Maximum load ANC108A Over-run timer Adjustable time delay between 2-25 minutes after the room has been vacated W 89mm H 89mm D 54mm* 5 amps ANC802A Humidistat with over-run timer The Intelligent Humidity Control (IHC)

SPECIFICATION & INSTALLATION OVERVIEW PLASTIC FLATDUCT PLASTIC FLATDUCT COMPONENTS AVAILABLE Low profile allows concealment within ceiling voids and cavity walls & above cupboards

Tags:

  Installation, Specification, Overview, Specification amp installation overview

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SPECIFICATION & INSTALLATION OVERVIEW

1 SPECIFICATION & INSTALLATION OVERVIEW REMOTE ELECTRICAL ANCILLARIES ELECTRICAL ANCILLARIES MODELS AVAILABLE For fans designed for remote switch operation Unobtrusive, attractive designs, manufactured in polycarbonate thermo-plastic Comply with relevant EMC directives All remote controllers can be flush or surface mounted using a standard single gang box Code Model Dimensions Maximum load ANC108A Over-run timer Adjustable time delay between 2-25 minutes after the room has been vacated W 89mm H 89mm D 54mm* 5 amps ANC802A Humidistat with over-run timer The Intelligent Humidity Control (IHC)

2 Works on detection of a significant change in the rate of increase in humidity levels. Whilst traditional humidistat controls wait for the humidity to reach a pre-set level, IHC detects a significant increase in a location s humidity level and activates the extract fan immediately. Timer adjustable between 2-25 minutes W 89mm H 89mm D 54mm* 5 amps ANC808A Humidistat with pull-cord switch The Intelligent Humidity Control (IHC) works on detection of a significant change in the rate of increase in humidity levels.

3 Whilst traditional humidistat controls wait for the humidity to reach a pre-set level, IHC detects a significant increase in a location s humidity level and activates the extract fan immediately. Neon indicator and pull-cord override W 89mm H 89mm D 54mm* 5 amps ANC811A Power Filter Recommended for use when fans containing electronic controls are specified for use in conjunction with fluorescent lamps or in other situations when power pulses (spikes) are frequent W 86mm H 86mm D 19mm 2 amps ANC831A Heavy Duty Power Filter As per the ANC811A, but specifically designed for use with the TripleVent and Whole House Heat Recovery Systems W 86mm H 86mm D 19mm 3 amps ANC812A Two Speed Rocker Switch Provides two speed operation for twin speed fans Suitable for CDF101B/CDF151B & ENX1002SC W 89mm H 89mm D 54mm* 10 amps ANC813A PIR Switch with over-run Timer Activates by detecting body heat.

4 Detection area up to 5 metres. Integral adjustable timer between 2-25 minutes W 89mm H 89mm D 54mm* 15 amps ANC814A Variable Speed Controller Provides on/off and variable speed control W 89mm H 89mm D 54mm* 3 amps * NOTE : D 54mm includes 35mm surface mounted pattress box (supplied) 68 FLEXIBLE PVC DUCT Robust, lightweight ducting system ideal for through the wall applications or for connecting to a rigid duct Excellent flexibility for ease of INSTALLATION in awkward situations Easily cut to length and fitting directly to fan and grille spigots Made of PVC and fire rated to BS476 Parts 5,6,7 & 20 Available in 100mm (4 ) & 150mm (6 )

5 Diameters and in 3, 10 or 45 metre lengths DUCTING & ANCILLARIES SPECIFICATION & INSTALLATION OVERVIEW COMPONENTS AVAILABLE Flexible Duct ANC503BT 100mm (4 ) 3m length ANC503C 120mm (5 ) 3m length ANC504B 150mm (6 ) 3m length ANC505B 100mm (4 ) 10m length ANC505C 120mm (5 ) 10m length ANC506B 150mm (6 ) 10m length ANC505A 100mm (4 ) 10m length insulated ANC645A 100mm (4 ) 45m length ANC507B 200mm (8 ) Aluminium 6m length ANC508B 250mm (10 ) Aluminium 6m length ANC530A 200mm (8 ) Galvanised Spiral 3m Reducers Fire Dampers (1 hour rated) Plastic Duct Clips (sold in 10 s) Jubilee Clips (sold in 2 s) ANC825A 100mm (4 ) ANC826A 150mm (6 ) Rigid PVC Duct ANC531A 100mm (4 ) 3m length ANC532A 150mm (6 ) 3m length Fixing Brackets (sold in 10 s) ANC533A 100mm (4 ) ANC534A 150mm (6 ) Coupling & Flexi-Rigid Adaptor ANC535A 100mm (4 )

6 PVC ANC536A 150mm (6 ) PVC ANC541A 200mm (8 ) galvanised - male Tee Piece ANC574A 100mm (4 ) for flexi duct ANC537A 100mm (4 ) for rigid or flexi duct ANC538A 150mm (6 ) for rigid or flexi duct ANC575A 200mm (8 ) for rigid aluminium ANC818A 100mm (4 ) ANC827A 150mm (6 ) ANC829A 100mm (4 ) ANC830A 150mm (6 ) Fire Collars (4 hour rated) ANC823A 100mm (4 ) ANC824A 150mm (6 ) (2 hour rated) ANC816A 200mm (8 ) ANC583A 100 - 75mm ANC584A 150 - 120 - 100mm ANC586A 200 - 150mm ANC582A 100 - 75mm Condensation Trap for Rigid Duct ANC543A 100mm (4 ) ANC544A 150mm (6 ) In-line Backdraught Shutters ANC539A 100mm (4 ) ANC540A 150mm (6 )

7 90 Bends RIGID PVC DUCT Designed for applications where long duct runs are required Push-fit components provide quick, simple INSTALLATION Large range of ancillaries available including bends, couplings & T pieces Strong, durable construction, flame retardant uPVC to UL 94 V2 Available in 100mm (4 ) & 150mm (6 ) diameters and in 3 metre lengths TYPICAL INSTALLATION TYPES 69 DUCTING & ANCILLARIES SPECIFICATION & INSTALLATION OVERVIEW PLASTIC FLATDUCT PLASTIC FLATDUCT COMPONENTS AVAILABLE Low profile allows concealment within ceiling voids and cavity walls & above cupboards 4 sizes available to accommodate different ventilation requirements.

8 110mm x 54mm (4 x 2 ), 204mm x 60mm (8 x 2 ), 225mm x 25mm (9 x 1 ) and 300mm x 25mm (12 x 1 ) Made in light uPVC which is flame retardant to BS476, DIN4102, B1, M1 and UL 94 V2 Strong durable PVC construction for long life and rigidity Lightweight, push-fit components for simple, quick INSTALLATION Comprehensive range of accessories inc. bends, couplings & airbricks Attractive, white appearance Code Description Code 248mm (10 ) 54mm (2 ) 110mm (4 ) 300mm (12 ) 127mm (5 ) A B C D E PFL 420A Fan Ceiling Box Female 58mm (2 ) 114mm (4 ) 100mm (4 ) A B C PFL 421A Plenum connect 100mm to Flatduct Female PFL 422A A BC 65mm (2 ) 209mm (8 ) 100mm (4 ) 65mm (2 ) 210mm (8 ) 51mm (2 ) 107mm (4 )

9 A B C D PFL 424A Airbrick Adaptor Female No 204x60 Airbrick Adaptor available Airbrick fits directly to duct 100mm (4 ) 114mm (4 )58mm (2 ) A B C PFL 425A Adaptor - 100mm Round to Flatduct Female PFL 426A A B C 100mm (4 ) 209mm (8 )65mm (2 ) 114mm (4 )58mm (2 ) A B PFL 427A 90 Horizontal Bend Female PFL 428A A B 209mm (8 )65mm (2 ) 114mm (4 )58mm (2 ) A B PFL 429A 90 Vertical Bend Female PFL 430A A B 209mm (8 )65mm (2 ) 1500mm 54mm(2 ) 110mm(4 ) ABC PFL 431A Plastic Flatduct length - Male PFL 432A A B C 1500mm 60mm (2 ) 204mm (8 ) 114mm (4 )100mm (4 ) 58mm (2 ) A B C PFL 433A Connector - Female PFL 434A A B C 209mm (8 ) 124mm (5 ) 65mm (2 ) 116mm (4 )60mm (2 ) A B PFL 435A Fixing Brackets (sold in 10 s) PFL 436A A B 211mm (8 ) 67mm (2 ) 110 x 54mm (4 x 2 ) 204 x 60mm (8 x 2 )

10 70 PLASTIC FLATDUCT Code Description Code PFL 458A Plenum 100mm round to Flatduct Female PFL 445A PFL 455A 90 Horizontal Bend Female PFL 462A PFL 453A 45 Horizontal Bend Male PFL 449A PFL 452A 45 Vertical Bend Male PFL 451A PFL 456A 90 Vertical Bend Male PFL 463A PFL 469A Adaptor - Connect 100mm to Flatduct Female PFL 450A Length Flatduct Female PFL 446A PFL 505A Connector Male PFL 506A PFL 437A PFL 439A Plastic Single Airbrick Airbricks are designed to fit inside either Airbrick Adaptor (PFL424A) or 204mm x 60mm Flatduct (PFL432A) Available in Terracota or Sandstone P