Example: quiz answers

Varplus M LV capacitors from 230V to 690V - …

Varplus M LV capacitorsfrom 230V to 690Vm o d u l a r i t ys i m p l i c i t ys a f e t yGet more with the world's Power & Control specialistSafety of personnel and installationsc the technology of Varplus M capacitors isbased on the use of self healing polypropylenefilm requiring no gas or liquid M capacitors make it easy to covera wide range in voltage (from 230 V to 690 V)and in power up to 100 kvar from a limitednumber of ratings are obtained by:c the use of Varplus M1 or Varplus M4capacitors alone,c the assembly of several Varplus M1capacitors,c the assembly of one Varplus M4 capacitorwith one or several Varplus M1 these assembly configurations stockmanagement and future power evolution aremade very modular rangeVarplus M1 Varplus M4c the HQ protection system integrated intoeach capacitor element provides total unique design, patented, it has been usedfor more than 10 years on several the HQ protection syst

c the design of Varplus M capacitors meets key principles of LV electrical distribution products to which they are associated in electrical switchboards: simple assembly on …

Tags:

  Assembly, Switchboards, Varplus

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Varplus M LV capacitors from 230V to 690V - …

1 Varplus M LV capacitorsfrom 230V to 690Vm o d u l a r i t ys i m p l i c i t ys a f e t yGet more with the world's Power & Control specialistSafety of personnel and installationsc the technology of Varplus M capacitors isbased on the use of self healing polypropylenefilm requiring no gas or liquid M capacitors make it easy to covera wide range in voltage (from 230 V to 690 V)and in power up to 100 kvar from a limitednumber of ratings are obtained by:c the use of Varplus M1 or Varplus M4capacitors alone,c the assembly of several Varplus M1capacitors,c the assembly of one Varplus M4 capacitorwith one or several Varplus M1 these assembly configurations stockmanagement and future power evolution aremade very modular rangeVarplus M1 Varplus M4c the HQ protection system integrated intoeach capacitor element provides total unique design, patented, it has been usedfor more than 10 years on several the HQ protection system provides protectionagainst the two fault types met in capacitor endof life.

2 Protection against high current faults isprovided by an HRC cartridge fuse. Protectionagainst low current faults is provided by thecombination of an overpressure disconnectdevice and the HRC whatever the fault pressure inside thecapacitor element is always limited to a valuefar lower than the maximum in both fault types the electrical current isalways opened by a standard HRC the plastic enclosure of Varplus M capacitorsoffer double electrical insulation. Plasticmaterials used provide both excellentmechanical properties and maximum selfextinguishing ratings (UL 94 5 VB certification).Configuration examples 400 V 50 HzCross-section of a capacitor elementHRCfuseOverpressuredisconnectdevi ceMetallicdisc15 + 15 = 30 kvar15 + 12,5 + 12,5 = 40 kvar60 + 15 = 75 kvar50 + 15 + 15 = 80 kvar60 + 15 + 12,5 + 12,5 = 100 kvar+++++++++c the design of Varplus M capacitors meets keyprinciples of LV electrical distribution products towhich they are associated in electricalswitchboards: simple assembly on vertical plate,fast connection on power their simplicity can be found in the ergonomicdesign details.

3 Standardized dimensions, front orrear connection, simple and original fingercontact protection, IP 42 protection with theaddition of a cable entry of mounting and connectionConnectionAccessoriesRear connectionFront connectionRear connectionFront connectionVarplus M1c their ingenious design allows the totaloccupied volume to be very compactand eases the cooling of the use of functional plates makes it easyto standardize the installation of capacitorsin panels and to simplify the maintenanceof power factor correction M4ref. 52461front connectionref. 52460frontconnectionref. 52462front connectionref. 52464front connectionVarplus M1 Varplus M4 ISO9001 CERTIFICATIONQUALITYC apacitor referencesand ratings (kvar)

4 400 V / 415 V50 Hz60 Hz50/60 Hz400 V415 V400 V415 V52417 Varplus M1555,5652418 Varplus M17,57,59952419 Varplus M1101012,513,552420 Varplus M112,512,5151652421 Varplus M115151819,552422 Varplus M45050606052423 Varplus M460657075230 V / 240 V50 Hz60 Hz50/60 Hz230 V240 V230 V240 V52410 Varplus M12,52,53352411 Varplus M13,844,5552412 Varplus M155,566,552413 Varplus M15,5677,552414 Varplus M17,58,59,51052415 Varplus M43033364052416 Varplus M432,5354042,5440 V / 470 V50 Hz60 Hz50/60 Hz440 V470 V440 V470 V52424 Varplus M14,555652425 Varplus M1788,59,552426 Varplus M1910101252427 Varplus M112,514,5151752428 Varplus M11416171952429 Varplus M45057,56069,552430 Varplus M455606575480 V / 525 V50 Hz60 Hz50/60 Hz480 V525 V480 V525 V52431 Varplus M15667,552432 Varplus M18101012,552433 Varplus M11012,512,51552434 Varplus M112,515151852435 Varplus M44050506052436 Varplus M450606070550 V / 590 V50 Hz60 Hz50/60 Hz550 V590 V550 V590 V52437 Varplus M15,566,57,552438 Varplus M11012,512,51552439 Varplus M112,514,5151752440 Varplus M44050506052441 Varplus M450586070600 V / 690 V50 Hz60 Hz50/60 Hz600 V690 V600 V690 V52442 Varplus M12,53,53452443 Varplus M1576,58,552444 Varplus M1811101352445 Varplus M1101412,516.

5 552446 Varplus M43345405052447 Varplus M440555066 Optionsfinger contact protectionr of 3 terminal covers for Varplus M1 - front connection52461set of 3 terminal covers for Varplus M1 - rear connection52466set of 3 terminal covers for Varplus M4front connection or rear connection52462set of 3 terminal covers for Varplus M4rear connection with special cable lug52463IP 42 protectionthree phase cable entry box for Varplus M152460three phase cable entry box for Varplus M452464IP 54 protectionon request standardsIEC 60831-1 and 2, NF C 54-104, VDE 0560 Teil 41, CSA 22-2 N 190 tolerance on capacitance values0, +10% lossesi W/kvar discharge resistors included insulation level50 Hz 1 min withstand voltage: 6 kVimpulse wave withstand: / 50 s 25 kV if the rear panel is at least 15 mm away from all metal frames 11 kV if the rear panel is up against a metal frame maximum assembly configurations (kvar)temperature classmaxhighest averagereactive power (kvar)over all period of: admissible current overloads30% admissible voltage overloads10% (8 h in 24 h specifed by IEC 831 1 and 2) colorsbase: RAL 9002 - elements: RAL 9005 - terminal covers: RAL 9002 weightVarplus M1: kg - Varplus M4.

6 10 kg* using Varplus M4 power terminationTechnical specifications230/240 V400/415 V440/470 V480/525 V550/590 V600/690 VM1+M1 assembly front connection30 kvar60 kvar60 kvar60 kvar60 kvar60 kvarM1+M1 assembly rear connection15 kvar30 kvar30 kvar30 kvar30 kvar30 kvarM4+M1 assembly (*) rear or front connection60 kvar100 kvar100 kvar100 kvar100 kvar100 kvar24 hours 1 year230/240 V400/415 V440/470 V480/525 V550/590 V600/690 V-25/D55 C45 C35 Cup to 40 kvar up to 65 kvar up to 76 kvar up to 85 kvarup to 100 kvar up to 100 kvar-25/C50 C40 C30 C41 to to 9077 to 10085 to 100-25/B45 C35 C25 C51 to to 100 ART 7453001-2002 Schneider Electric Industries SARectiphaseBP1074371 Pringy cedexFranceTel.

7 : (33) 04 50 66 95 00 Fax: (33) 04 50 27 24 19As standards, specifications and design develop from time to time, always ask for confirmationof the information given in this : Studio Insign' - AMEGP ublishing: Schneider ElectricPrinting: Colorpress - 1000 6,5x13M81928395,5 7 Varplus M421021819295,5M8 7116 Varplus M1 CFIED196028EN 2002 Schneider Electric - All right reservedThis document has been printed on ecological paper